Images in intervention
Patient-prosthesis mismatch after mitral valve-in-valve procedure – at the cost of life or serious consequence?

Dariusz Jagielak
,
Radoslaw Kozaryn
,
Miłosz Jaguszewski
,
Jan Rogowski

Postep Kardiol Inter 2015; 11, 2 (40): 154–155
Online publish date: 2015/06/22
View full text Get citation
 

An 81-year-old man, who had undergone a complex cardiosurgical procedure 8 years previously (aortic valve replacement by Medtronic Hancock II 23 mm and mitral valve replacement by Medtronic Hancock II 31 mm, tricuspid valve repair using the Kay technique, and coronary artery bypass surgery with left internal mammary artery (LIMA) to left anterior descending (LAD)), was admitted to the hospital with symptoms suggestive of acute heart failure (NYHA IV). Echocardiographic examination revealed satisfactory function of the aortic prosthesis, and massive regurgitation of the degenerative mitral prosthesis. Left ventricle ejection fraction was estimated at approximately 30% with left ventricle (LV) thinning, an akinetic and thin apex, and mild tricuspid valve insufficiency. Due to these findings cardiopulmonary bypass was used. An intra-aortic balloon pump (IABP) was not introduced due to limited femoral access. The patient, in spite of a very high operative risk (STS 29.8%), was referred for urgent redo cardiac surgery. With this in mind, the patient was qualified for transcatheter mitral valve-in-valve (VIV) implantation.
The procedure was performed on-pump with the cardiopulmonary bypass connected via femoral vessels. A transapical approach for delivering the 29 mm Edwards Sapien valve into the mitral position was chosen. Significant efforts were made to protect the scarred apex (pericardium was not dissected). Intraoperative transesophageal echocardiogram (TEE) and fluoroscopy demonstrated precise landing of the new prosthesis, as well as resolution of prior regurgitation and absence of perivalvular leakage. Unfortunately, the initially high mean gradient through the valve remained elevated. The postoperative course was uneventful. On postoperative day 5 in the Cardiology Department due to left ventricular end-diastolic diameter (LVED) > 70 mm and one incidence of tachyarrhythmia, a cardioverter-defibrillator was implanted prophylactically. The patient was discharged home 2 weeks after the procedure. The patient remains in stable condition in class II/III NYHA after 10 months of follow-up. Control echocardiography showed moderate/severe stenosis (mitral valve area 1.0 cm2, mean diastolic pressure gradient (PG) 9 mm Hg) of the implanted VIV prosthesis with no perivalvular leakage and degenerative changes of the leaflets.
Though the problem of low mitral valve orifice after transcatheter VIV implantation has been deliberated in the...