eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2016
vol. 12
 
Share:
Share:
abstract:
Original paper

Blood glucose concentration for predicting poor outcomes in patients with and without impaired glucose metabolism undergoing off-pump coronary artery bypass surgery – long-term observational study

Wojciech Szychta
,
Franciszek Majstrak
,
Grzegorz Opolski
,
Krzysztof J. Filipiak

Adv Interv Cardiol 2016; 12, 3 (45): 238–246
Online publish date: 2016/08/19
View full text Get citation
 
Introduction: Strict glucose control is an everyday practice in the perioperative period. Elevated glucose level has a deleterious impact on clinical results, but a therapeutic target has not been stated yet.

Aim: To determine a glucose concentration range affecting long-term outcomes after coronary artery bypass surgery (CABG).

Material and methods: This study is a retrospective evaluation of consecutive patients treated in a university hospital in Poland from 2004 to 2008. Patients were divided into 2 groups: an impaired glucose metabolism group (IGM) if they had 1) known DM or 2) perioperative hyperglycaemia defined as ≥ 200 mg/dl; and a non-IGM group. The end point (EP) was all-cause mortality.

Results: One thousand two hundred and eleven patients were covered by the analysis. The observation time was from 01.01.2004 until 01.08.2012. Patients who had maximal glucose concentrations < 242 mg/dl had the lowest mortality risk (EP in 21.1%); a higher risk was noted in the group with glucose concentrations 242–324 mg/dl (EP in 30.8%); and a very high risk was found for the group where glucose concentration was > 324 mg/dl (EP in 44.2%) (p = 0.041). Patients with IGM had a shorter survival at the end of the study (p < 0.001). The longest survival was observed in patients whose maximal glucose level was ≤ 242 mg/dl (p < 0.001) and the minimal glucose concentration was in the range 61–110 mg/dl (p < 0.001).

Conclusions: Tight glucose concentration control should be performed irrespective of a diabetes diagnosis and proper treatment introduced when necessary. Maximal glucose concentration should be kept < 242 mg/dl, while the minimum should be in the range 60–110 mg/dl.
keywords:

diabetes, concentration, glucose, mortality, off-pump coronary artery bypass surgery, off-pump

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.