eISSN: 1897-4252
ISSN: 1731-5530
Kardiochirurgia i Torakochirurgia Polska/Polish Journal of Thoracic and Cardiovascular Surgery
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Abstracting and indexing Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2013
vol. 10
 
Share:
Share:

CARDIAC SURGERY
Clinical and echocardiographic predictors of recurrent mitral regurgitation following restrictive mitral annuloplasty. Evaluation in patients with chronic ischemic mitral regurgitation

Witold Streb
,
Tomasz Niklewski
,
Dariusz Puszczewicz
,
Tomasz Kukulski
,
Roman Przybylski
,
Jerzy Pacholewicz
,
Marian Zembala

Kardiochirurgia i Torakochirurgia Polska 2013; 10 (2): 99–104
Online publish date: 2013/07/09
Article file
- 01 Streb.pdf  [0.75 MB]
Get citation
 
PlumX metrics:
 

Introduction

Ischemic heart disease is often complicated by mitral regurgitation (MR). Mitral valve (MV) insufficiency may occur acutely as a complication following acute myocardial infarction (AMI). It may also develop chronically in patients following post-myocardial infarction (MI) LV remodeling, i.e. as functional ischemic mitral regurgitation (FIMR) [1]. The analysis of a large cohort of patients (11 000) with angiographically confirmed significant coronary artery stenoses showed that FIMR was present in about 19% of them [2] (Fig. 1). There is evidence that MR is a powerful predictor of risk in patients after myocardial infarction. Patients with ischemic MR have higher incidence of cardiovascular mortality (29% vs. 12%) and heart failure (24% vs. 16%) than patients without ischemic MR at a mean of 3.5 years after MI [3]. The presence of ischemic MR was found to be a strong predictor of cardiac events independently of left ventricular systolic and diastolic indexes in patients with ischemic heart disease [4].

The management of ischemic MR remains controversial. The possible therapeutic approaches are: MV replacement with coronary artery revascularization, MV repair with revascularization, or revascularization alone. Significant reduction in MR can be expected in only about 10% of patients after revascularization alone [5], whereas MV repair or replacement can eliminate or decrease regurgitation in most cases. Although the meta-analysis conducted by Shuhaiber and Anderson of clinical outcomes following surgical MV repair or replacement did not reveal any significant differences in total survival, especially MV repair is associated with lower 30-day mortality due to lower rates of thromboembolism, infections, and the risk of future reoperation [6].

The standard surgical repair consists in undersized annuloplasty, resulting in a decrease in mitral annulus diameter and, thus, in an increase of leaflet coaptation [7]. However, it is reported that, despite adequate patient selection and standard surgical operative techniques, up to 7-30% of patients after mitral annuloplasty exhibit recurrent MR [8, 9]. The prediction of recurrent MR after MV repair may guide clinicians when making decisions concerning qualifying patients for mitral repair or replacement. The aim of this study was to determine the clinical and echocardiographic predictors of recurrent MR after restrictive mitral annuloplasty (RMA) and to create a model for risk stratification in patients operated on for ischemic MR.

Material and methods

Patients



The analyzed group consisted of 165 consecutive patients (100 men and 65 women) at the mean age of 64.3 ±7.7 years from a series of 336 patients operated on for ischemic heart disease and moderate to severe MR in the Silesian Center for Heart Diseases in Zabrze. Based on echocardiographic and surgical findings, only the patients with ischemic MR were included into the study. Cases with mitral insufficiency due to other pathologies (e.g. rheumatic, infectious or myxomatous) were excluded. All patients underwent surgical heart revascularization and successful MV repair with undersized ring implantation.

The patients’ risk associated with cardiac surgery was calculated based on EuroSCORE and ranged from 1 to 17 with a median of 6.6 ±2.5. 85.4% of patients had sinus rhythm. Mean body mass index (BMI) and BSA were 27.1 ±4.2 and 1.86 ±0.45. Co-morbidities of the study population included diabetes (41.2%), chronic AF (14.6%), hypertension (80%), hyperlipidemia (89.1%), and peripheral vascular disease (60.2%).

90.3% of patients had a history of previous MI. The inferior wall was the most common wall to be affected by infarction [111 patients (67.3%), lateral wall 40.1% and anterior wall 31.5%]. The majority of patients (57.5%) suffered from three-vessel disease, 29.1% from two-vessel disease, and a significant narrowing of a single coronary artery was present in 12.7% of the study population.

105 patients (63.6%) had left ventricular ejection fraction (LVEF) (measured in transthoracic echo with the Simpson formula) between 30 and 50%, 34 (20.6%) had LVEF above 50%, and 26 (15.8%) had it lower than 30%.



Echocardiographic study



All patients underwent transthoracic echocardiographic evaluation prior to cardiac surgery, 5-10 days after the operation, and 8 to 21 months thereafter (median follow-up was 13 months). During the cardiac surgery, transesophageal echocardiography was performed to assess the results of the annuloplasty. Transthoracic examinations were performed with GE VIVID 5 and 9 ultrasound systems with 2.5 MHz transducers, and they were stored digitally. Echocardiographic assessment was performed in standard views by two experienced echocardiographers, in accordance with the recommendations of the American Association of Echocardiography.

The dimensions of the heart chambers were measured in parasternal long axis view in M-mode. Real-time 2D images in two- and four-chamber views were acquired for the assessment of the MV regurgitation mechanism and for the estimation of left ventricular volumes, dimensions, and contractility. The mechanism of MR was categorized according to the Carpentier classification. Only patients with type I or IIIb were included in the study.

The severity of MR was evaluated based on the following quantitative Doppler-derived parameters: effective regurgitant orifice area (EROA) and regurgitant volume. 73 patients (44.2%) presented moderate, and 92 (55.8%) severe preoperative MR. Carpentier type I was demonstrated by 74 (44.8%) and type IIIb by 91 study patients (55.2%).



Surgical procedure



The ischemic etiology of MR was confirmed by visual inspection of the mitral leaflets, annulus, chordae tendineae, and papillary muscles during cardiac surgery. If the mitral leaflets and the chordae appeared normal but there were signs of ischemia or infarction involving papillary muscles or signs of mitral annulus dilatation due to post-MI LV dilatation, then the ischemic etiology of regurgitation was concluded. Ischemic MR was repaired by undersized ring annuloplasty. Carpentier-Edwards classic ring implantation was performed in 79 patients (47.9%). 83 patients (50.3%) were implanted with Carpentier-Edwards physio rings, 1 patient (0.6%) was implanted with a Carpentier MC-A ETlogix, and the remaining 2 (1.2%) received Duran rings. The ring size varied from 24 to 32. In 157 patients, the ring size did not exceed 28; 113 patients (68.5%) received size 26 rings.

Beside the mitral annuloplasty, 92.1% of patients had a coronary artery bypass grafting procedure. 29 patients (17.6%) underwent concurrent repair of the tricuspid valve, 4 patients aortic valve repair, and surgical ablation for atrial fibrillation was performed in 14 subjects.



Postoperative follow-up



All patients were followed up with transthoracic echocardiographic examination. Median follow-up was 13 months (it varied from 8 to 21 months).



Statistical analysis



The results are presented as mean and standard deviation. Logistic regression was used for univariate and multivariate analysis of continuous variables. Specificity and sensitivity were calculated based on ROC analysis.

Results

The comparison of mitral valve regurgitation prior to MV repair and after the follow-up period (mean of 13 months, 8-21), as examined by transthoracic echocardiography, showed that the good results of the operation are long lasting. In the study population, the mean MR, qualitatively categorized to one of four classes, was 3.46 ±0.5 preoperatively, whereas after the observation period it was 0.98 ±1.39 (p < 0.001). Significant regurgitation recurred in 30 patients (18.2%): severe in 11 cases (6.7%) and moderate in 19 (11.5%). Furthermore, the coaptation length, which is one of the predictors of successful MV repair, was significantly greater in the early postoperative period than before the operation (0.72 ±0.2 cm vs. 0.21 ±0.09 cm, p < 0.001); this effect was sustained over the follow-up (0.68 ±0.2 cm; p < 0.001). However, mitral annuloplasty did not influence coaptation depth (0.62 ±0.23 cm preoperatively vs. 0.63 ±0.22 cm postoperatively).

The positive long-term effect of MV repair was also reflected by the quantitative echocardiographic parameters of MR. Preoperatively, the EROA and regurgitant volume were, respectively, 0.44 ±0.16 cm2 and 57 ±25.3 ml, whereas in follow-up these parameters were significantly reduced (EROA: 0.28 ±15 cm2; p < 0.001 and regurgitant volume: 38 ±21.6 ml; p < 0.001).

The assessment of left ventricular (LV) function and geometry seems to be as important as the assessment of MR itself in patients treated with surgical annuloplasty. Both global and regional LV remodeling is a causative factor for MV insufficiency, and, thus, it may potentially influence MR recurrence. In our study, no significant changes were found in either systolic or diastolic dimensions and volumes, either before the operation or postoperatively (Table I).

However, the follow-up echocardiographic assessment revealed significant changes in LV geometry, as the systolic and diastolic indexes were reduced significantly after the operation, indicating favorable global remodeling after MV surgery (Table II).

The univariate analysis showed that a number of factors have an influence on the recurrence of MR in long observation. As presented in Tables III and IV, the preoperative echocardiographic parameters dominate over the clinical and perioperative predictors.

The strongest predictor was the coaptation length measured directly after mitral ring implantation (OR 0.0022; p = 0.001), followed by EROA (OR was 1.85; p < 0.002) and vena contracta, measured preoperatively (OR 57.28; p = 0.001). None of the non-echocardiographic factors had a significant relation with the recurrence of MR in the follow-up.

The multivariate analysis showed that, among the analyzed factors, only the coaptation length measured postoperatively was capable of independently predicting the recurrence of MR in long-term observation (OR 0.01; CI: 0.00-0.42; p = 0.001). The ROC analysis showed that the cut-off value of 0.62 cm for coaptation length is characterized by 94% sensitivity and 85% specificity with regard to predicting MR recurrence. The independent risk factors of the multivariate logistic regression analysis and our model of risk stratification of MR recurrence are presented in Fig. 2 and Table V.

Discussion

The rate of recurrent MR in the studied cohort of patients was relatively low. The literature reports that severe MR may occur in up to 30% of patients after mitral annuloplasty [10]. Recurrence of MR is associated with the operational technique employed, the surgeon’s skill, and the progression of remodeling. Intraoperative assessment of surgical results can also play an important role. Transesophageal echocardiography routinely performed during the operation can adequately distinguish between successful and unsuccessful annuloplasty; such an approach is a standard in our center. The rate of unsuccessful mitral annuloplasty is reported as approximately 20% [10]. Unfortunately, our data are lacking information regarding the percentage of unsuccessful annuloplasty procedures. On the other hand, there are no unique criteria of unsuccessful MV repair. To the knowledge of the authors, there are no published data regarding the intraoperative, quantitative, and complex assessment of MV repair results, so echocardiographers use different criteria depending on their own preference.

The results of our study demonstrate that detailed echocardiographic examination can identify the patients who are likely to develop recurrent MR after undersized ring implantation. The EROA, vena contracta of the regurgitant jet, and LV systolic sphericity index at the level of medial segments were found to be the strongest predictors. None of the clinical or procedure-related factors had an influence on MR recurrence in the studied population, even though, in the literature, the impact of procedure-related factors and echocardiographic assessment was highlighted as an independent risk factor from the etiology of MV insufficiency [11].

Several studies have emphasized the role of echocardiography in the prediction of MR recurrence after mitral annuloplasty. Calafiore and colleagues found that the coaptation depth of more than 11 mm was associated with an increased risk of recurrent MR in patients with dilated cardiomyopathy [12]. In a more recent study, Kongsaerepong et al. demonstrated in a group of patients with ischemic MR that the results of mitral surgery are influenced not only by tethering height, but also by mitral annular dimension and MR grade [10]. The annular dimension of ≥ 3.7 cm in TEE, with a tenting area of ≥ 1.6 cm2 in long axis view and MR grade > 3.5, was associated with the failure of mitral annuloplasty in half of the patients during follow-up. Both the coaptation depth (tethering height) and tenting area reflect left ventricular remodeling resulting in mitral leaflet tethering. Our study did not confirm the predictive role of coaptation depth. However, these parameters have a burden of error, due to the difficulties presented by their measurement. Various results can be achieved depending on the annular plane estimation and on the quality of the echocardiographic view. Moreover, our study included patients with the mechanism of MR classified as Carpentier types I and IIIB, which dramatically differ in terms of the expected measurement results of the discussed parameters. Thus, our study does not aim to devalue the importance of coaptation depth or tenting area, but rather to show that the use of these parameters is less universal than that of other parameters.

We found that coaptation length assessed within days after operation was the strongest predictor of MV regurgitation recurrence. This parameter can be assumed to be the same as the measurement obtained directly at the operation theatre. Approximately 40% of patients with the postoperative coaptation length of ≤ 6.7 mm had severe MR revealed by the follow-up echocardiographic examination. Similarly, the Leiden University study aimed to achieve the coaptation length of at least 8 mm as the target of restrictive ring implantation, as this value was associated with very low incidence of MR recurrence – 2.3% [13].

The reduction of coaptation length reflects the remodeling of the left ventricle caused by ischemia. It can lead to either mitral annulus dilatation or papillary muscle displacement. The key role of ventricular remodeling was also considered as a risk factor of recurrent MR after undersized mitral ring implantation. Progressive postoperative remodeling, including further papillary displacement, may potentially be responsible for the failure of restrictive annuloplasty [8, 14]. Our study did not reveal any significant changes in LV dimensions and volumes, which called into question the feasibility of reverse LV remodeling after the correction of mitral insufficiency. However, the mean follow-up in our study was relatively short, which is particularly important in view of the Bax et al. report [15]. Its authors demonstrated that reverse remodeling of the LV is a gradual and time-dependent process, by observing the operated patients for a period of 1.5 years.

The reverse remodeling of the LV in our study was reflected in the significantly decreased sphericity indexes. According to Di Donato, the sphericity index is even more valuable than LV dimensions and volumes. It significantly correlates with the degree of MR and, conversely, does not increase even in large ventricles without MR [16].

Conclusions

This study showed that the recurrence of MR after undersized mitral ring implantation is low. The measure of coaptation length was found to be superior to other echocardiographic parameters in the prediction of MR recurrence after restrictive annuloplasty.

Study limitations

This study is lacking data on unsuccessful undersized ring implantation. The analysis was focused on the mechanistic implications of LV remodeling as a causative factor of functional MR, whereas the pathophysiology of MR can also be explained by the LV contraction dyssynchrony. As indicated by the conducted analysis, the primary practical aspect of this study concerns the reliance on intraoperative transesophageal measurements of coaptation length rather than on postoperative assessment. Our assumption that the results of intra- and postoperative results are similar should be verified.

References

1. Agricola E, Oppizzi M, Pisani M, Meris A, Maisano F, Margonato A. Ischemic mitral regurgitation: mechanisms and echocardiographic classification. Eur J Echocardiogr 2008; 9: 207-221.

2. Hickey MS, Smith LR, Muhlbaier LH, Harrell FE Jr, Reves JG, Hinohara T, Califf RM, Pryor DB, Rankin JS. Current prognosis of ischemic mitral regurgitation: implications for future management. Circulation 1988; 78 (Suppl 1): I51-I59.

3. Lamas GA, Mitchell GF, Flaker GC, Smith SC Jr, Gersh BJ, Basta L, Moyé L, Braunwald E, Pfeffer MA. Clinical significance of mitral regurgitation after acute myocardial infarction. Survival and Ventricular Enlargement Investigators. Circulation 1997; 96: 827-833.

4. Okura H, Takada Y, Kubo T, Asawa K, Taguchi H, Toda I, Yoshiyama M, Yoshikawa J, Yoshida K. Functional mitral regurgitation predicts prognosis independent of left ventricular systolic and diastolic indices in patients with ischemic heart disease. J Am Soc Echocardiogr 2008; 21: 355-360.

5. Kim YH, Czer LS, Soukiasian HJ, De Robertis M, Magliato KE, Blanche C, Raissi SS, Mirocha J, Siegel RJ, Kass RM, Trento A. Ischemic mitral regurgitation: revascularization alone versus revascularization and mitral valve repair. Ann Thorac Surg 2005; 79: 1895-1901.

6. Shuhaiber J, Anderson RJ. Meta-analysis of clinical outcomes following surgical mitral valve repair or replacement. Eur J Cardiothorac Surg 2007; 31: 267-275.

7. Reul RM, Cohn LH. Mitral valve reconstruction for mitral insufficiency. Prog Cardiovasc Dis 1997; 39: 567-599.

8. Tahta SA, Oury JH, Maxwell JM, Hiro SP, Duran CM. Outcome after mitral valve repair for functional ischemic mitral regurgitation. J Heart Valve Dis 2002; 11: 11-19.

9. McGee EC, Gillinov AM, Blackstone EH, Rajeswaran J, Cohen G, Najam F, Shiota T, Sabik JF, Lytle BW, McCarthy PM, Cosgrove DM. Recurrent mitral regurgitation after annuloplasty for functional ischemic mitral regurgitation. J Thorac Cardiovasc Surg 2004; 128: 916-924.

10. Kongsaerepong V, Shiota M, Gillinov AM, Song JM, Fukuda S, McCarthy PM, Williams T, Savage R, Daimon M, Thomas JD, Shiota T. Echocardiographic predictors of successful versus unsuccessful mitral valve repair in ischemic mitral regurgitagtion. Am J Cardiol 2006; 98: 504-508.

11. Gillinov AM, Cosgrove DM, Lytle BW, Taylor PC, Stewart RW, McCarthy PM, Smedira NG, Muehrcke DD, Apperson-Hansen C, Loop FD. Reoperation for failure of mitral valve repair. J Thorac Cardiovasc Surg 1997; 113: 467-473.

12. Calafiore AM, Gallina S, Di Mauro M, Gaeta F, Iacò AL, D’Alessandro S, Mazzei V, Di Giammarco G. Mitral valve procedure in dilated cardiomyopathy: repair or replacement? Ann Thorac Surg 2001; 71: 1146-1153.

13. Braun J, Bax JJ, Versteegh MI, Voigt PG, Holman ER, Klautz RJ, Boersma E, Dion RA. Preoperative left ventricular dimensions predict reverse remodeling following restrictive mitral annuloplasty in ischemic mitral regurgitation. Eur J Cardiothorac Surg 2005; 27: 847-853.

14. Hung J, Papakostas L, Tahta SA, Hardy BG, Bollen BA, Duran CM, Levine RA. Mechanism of recurrent mitral regurgitation after annuloplasty: continued LV remodeling as a moving target. Circulation 2004; 110: 1185-1190.

15. Bax JJ, Braun J, Somer ST, Klautz R, Holman ER, Versteegh MI, Boersma E, Schalij MJ, van der Wall EE, Dion RA. Restrictive annuloplasty and coronary revascularization in ischemic mitral regurgitation results in reverse left ventricular remodeling. Circulation 2004; 110 (11 Suppl 1): II103-II108.

16. Di Donato M, Dabic P, Castelvecchio S, Santambrogio C, Brankovic J, Collarini L, Joussef T, Frigiola A, Buckberg G, Menicanti L; RESTORE Group. Left ventricular geometry in normal and post-anterior myocardial infarction patients: sphericity index and ‚new’ conicity index comparisons. Eur J Cardiothorac Surg 2006; 29 Suppl 1: S225-S230.
Copyright: © 2013 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska). This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.