2/2013
vol. 10
CARDIAC SURGERY Early experience with implantation of the new biological Trifecta valve
Kardiochirurgia i Torakochirurgia Polska 2013; 10 (2): 105–109
Online publish date: 2013/07/09
Get citation
PlumX metrics:
Introduction The first biological valves were successfully implanted in 1962 by Ross and Barrat-Boyes, and were called homografts or allografts. Those valves were derived from cadavers, unlike autografts, i.e. autologous grafts from the pulmonary artery, which were successfully implanted for the first time in 1967 [2]. In the 1960s the method of porcine preservation was developed by Carpentier and coworkers. A little later bovine valves were preserved in glutaraldehyde, which was a milestone in the field of bioprostheses. The advantages of all bioprostheses included reduced incidence of thromboembolic complications and no need for anticoagulation treatment. Tissue valve technology has been developed over the past 50 years and includes anticalcification and fixation methods, hemodynamic performance, durability or design. That is why the number of bioprostheses implanted worldwide has risen from 30% to 85% over the past 15 years and the biological stented valves are the main prostheses used for aortic valve replacement (AVR) [3]. This also applies to Poland, where the number of implanted biological stented valves has increased significantly from 32% to 53% over the past 5 years [4].
The study presents early single center experience with the new Trifecta valve (St. Jude Medical, Inc.).Material and methodsThe prospective study included 38 elective patients who underwent aortic valve replacement using the Trifecta valve between March 2011 and December 2012 in the Central Clinical Hospital of the Ministry of Interior in Warsaw. The mean age was 64.4 ±11.7 within 21 male patients (55%). The main patients’ comorbidities were hypertension (63%), diabetes (18.4%), and coronary artery disease (47%). All demographic data are presented in Table I. The main cause of surgical intervention was severe aortic stenosis (71%) and aortic regurgitation due to endocarditis (10.5%) or aortic aneurysm (13.1%). The overall mean aortic gradient was 41.3 ±18.3 mm Hg and overall aortic orifice area was 0.9 ±0.5 cm2. The mean Logistic EuroSCORE was 7.58 ±6.15% and EuroSCORE II 2.56 ±2.08%.
The less invasive technique was the purpose of the surgical access but it depended on the concomitant procedure. Upper mini-sternotomy was preferred for isolated AVR or ascending aortic replacement with AVR. The technique consists of 7-9 cm skin incision and V-shape upper-sternotomy maximally reaching the 4th rib. For better operative area visualization, the vein cannula and vent were protracted through the 2 cm incision under the xiphoid process which was also used for a mediastinal drainage after the procedure. In other cases a classical median sternotomy was performed. A cardiopulmonary bypass and mild hypothermia were applied in combination with cold blood or crystal cardioplegia. The native degenerated aortic valve was removed and the annulus was decalcified. 2-0 Ethibond horizontal mattress stitches with pledgets on the ventricular side were used for supra-annular valve implantation. The sternal closure technique was double criss-cross sternal wiring.
Prior to discharge from hospital, Trifecta valves were examined by transthoracic echo in all patients. Vitamin K antagonists were administered in a 3-month therapy protocol as antithrombotic prophylaxis.
Statistical analysis was performed by means of StatSoft, Inc. (2007) STATISTICA (data analysis software system), version 8.0. Correlations, descriptive statistics, T-test for independent samples and T-test for dependent samples were basic statistical calculations. Results All Trifecta valves were successfully implanted. Upper mini-sternotomy was done in 25 patients (66%) either for isolated AVR (20 patients) or AVR with ascending aorta replacement (5 patients). One patient had a combined procedure that consisted of non-coronary sinus repair with AVR and supra-coronary ascending aorta replacement through upper mini-sternotomy. In addition one Bentall de Bono procedure using a self-made conduit made with Trifecta sewn into the Dacron graft was performed through upper mini-sternotomy (Fig. 2). There was no conversion to full median sternotomy. Other concomitant procedures were coronary artery bypass graft (CABG) (8 patients), mitral valve replacement (3 patients), and tricuspid repair (2 patients) (Table II).
In 1 patient with a narrow aortic root, aorta enlargement using a polytetraflouroethylene (PTFE) patch was needed, which was associated with the relatively high profile of the prosthesis. Another patient had symptomatic PPM (patient prosthesis mismatch) which was the indication for reoperation; the other type of biological aortic prosthesis was replaced with the same size of Trifecta (19 mm) reaching significantly lower gradients and greater EOA (effective orifice area) (Fig. 3).
The mean cardiopulmonary bypass (CPB) time was 133.1 ±50.2 min and the mean ACC time was 93.1 ±35.5 min, strongly influenced by a few complicated procedures in that small cohort. Postoperative total drainage was 605.5 ±83 ml; however, less invasive access correlated with lower bleeding (433.6 ±252.9 vs. 935 ±364.1 ml; p = 0.00003) and lower blood transfusion rate (0.8 ±1.1 vs. 2.0 ±1.7 units; p = 0.01). Mean intubation time was 10.4 ±12.4 hours (Table III).
Postoperative transthoracic echo showed good function of the Trifecta valve and a transvalvular gradient decrease without significant paravalvular leak among all patients. In small roots (Trifecta valve size 19 mm and 21 mm) the mean gradient was 13 ±7.2 mm Hg. Valve size 23 mm or more had single digit mean gradients (Fig. 1).
The observed complications were tamponade (1 patient), wound infection (2 patients), delirium (3 patients), and acute renal insufficiency (1 patient). Total 30-day in-hospital mortality was 5.2% (2 patients). The first patient died due to postoperative stroke complicated by acute pneumonia and sepsis that was treated unsuccessfully with extracorporeal membrane oxygenation (ECMO). The second death was caused by an abdominal complication which did not responded to treatment in a patient after AVR, mitral valve plasty (MVP) and CABG. DiscussionTrifecta is a next-generation stented bovine pericardial heart valve for supra-annular placement with advanced design (Fig. 1). The valve’s unique features include a fatigue-resistant titanium stent with pericardium to reduce the risk of leaflet abrasion and structural valve deterioration (SVD) during the cardiac cycle. Furthermore, minimizing mechanical stress may play a key role in the tissue valve’s ability to resist calcification [5, 6]. To minimize calcification and deterioration, which can occur after implantation due to the presence of phospholipids in the tissue lipid deposits and elevated calcium metabolism, Linx anticalcification (AC) technology has been used. The durability of the Trifecta bioprosthesis was assessed in vitro by means of accelerated lifetime cyclic testing under dynamic conditions. Testing was performed on a valve at 1000 beats per minute with a mean aortic pressure gradient of 120 +20/-0 mm Hg. The results showed freedom from valve failure (reliability %) after 200, 400, 600 million cycles – 99.2% (5 years in vivo), 94.3% (10 years), 82.9 (15 years) respectively, and a fully functional valve after 1.25 billion cycles (approximately 31 years). There is an interesting design detail – the elimination of alignment stitches at the top of commissures – thanks to which the valve gives good hemodynamic performance (large EOA, Fig. 1), which has been demonstrated both in this study and in other available clinical single and multicenter trials.
In a clinical trial with two-year follow-up at the Hospital of the University of Pennsylvania, 100 Trifecta valves were implanted by Dr. Bavaria’s team as part of a prospective Food and Drug Administration (FDA) study between August 2007 and October 2009. Patients scheduled for AVR who met the study eligibility criteria received a Trifecta valve. Echocardiography, New York Heart Association (NYHA) classification and physical examination were used to assess hemodynamic performance and valve durability. The results show good hemodynamics which remained stable 2 years following the procedure. In 23 mm valve size (n = 35), the average mean gradients at discharge, 1 year, and 2 years were 7.9 ±3.8 mm Hg, 7.8 ±3.3 mm Hg, and 6.6 ±4.4 mm Hg, respectively. Measured indexed effective orifice area (EOAI, cm2/m2) remained stable during the study period. For 23 mm valve size (n = 35), EOAIs were 0.97 ±0.18, 0.84 ±0.19, and 0.95 ±0.14. The rate of PPM (EOAI < 0.65) was 3.7% at two years. NYHA classification at 6 months, 1 year, and 2 years after implantation demonstrated notable improvement in quality of life compared with preoperative assessments [7, 8]. These results confirm findings from a multicenter, multi-country (USA, Canada, Europe), prospective, non-randomized observational study with 1,022 Trifecta® valves implanted between June 2007 and November 2009. The most common valve size implanted was 23 mm (n = 335, 33%), preoperatively 49.3% of subjects were NYHA class III or IV, and at 1 year postoperatively 98.9% were NYHA class I or II. The average mean gradients for all sizes (19 mm to 29 mm) were ≤ 10.7 mm Hg at one year postoperatively. Large effective orifice areas EOAIs ≥ 0.85 cm2/m2 across all valve sizes reduce the risk of patient-prosthesis mismatch (PPM). Regurgitation at discharge was none or trivial in nearly all subjects, and 97% of them had either no or trivial regurgitation at one year [9]. In comparison with other bioprostheses in the same one-year follow-up period, the results for Trifecta are encouraging. In a prospective randomized study with Edwards Perimount Magna (EPM) and Medtronic Mosaic (MM) valves (23 mm size), the average mean gradients after 12 months were 10.3 ±3.8 mm Hg (EPM) and 15.8 ±6.2 mm Hg (MM), whereas indexed effective orifice areas (EOAIs) were 1.06 ±0.17 cm2 (EPM), and 0.88 ±0.07 cm2 (MM) [10]. Also in comparison with stentless and sutureless bioprostheses, Trifecta does not differ from the others. In the ASSERT prospective, multicenter, randomized 12-month trial, a stentless Freestyle valve (Medtronic, Inc) was compared with a stented Mosaic valve (Medtronic, Inc). The authors reported average EOAI (cm2/m2) after one year of 0.72 ±0.21 for stented, and 0.96 ±0.32 for stentless valve bioprostheses [11]. Another prospective, randomized, 12-month controlled trial comparing stentless vs. stented valve bioprostheses (Sorin Freedom vs. Sorin More) showed an average EOAI (cm2/m2) of 0.8 ±0.2 for stented and 1.1 ±0.3 for stentless valve bioprostheses [12]. Pillai et al. reported early (2-year trial) clinical results for the 3f Enable sutureless bioprosthesis with an average EOAI (cm/m2) of 1.0 ±0.4 [13]. To conclude, the Trifecta valve has shown good performance among stented bioprostheses, comparable with stentless/sutureless ones.
Implantation of the Trifecta valve requires basically the same standard technique, which can be considered an important advantage especially in the minimally invasive technique. However, due to the relatively high profile it can be difficult in patients with a narrow sino-tubular junction, which needs precaution. In our experience, however, it happened only once and was easily solved with aortic patch plasty.
Hemodynamic parameters both in our study and other Trifecta studies turned out to be very satisfactory. The good hemodynamic results in small valve sizes (19-21 mm) make Trifecta a realistic option for patients with a small annulus. While Trifecta is undoubtedly a promising valve on the bioprosthesis market, it should be noted that further follow-up is needed to assess its long-term durability, hemodynamic performance and adverse event rates. AcknowledgementsThe study was conducted using independent financial resources of the Department of Cardiac Surgery, Central Clinical Hospital MSW, Warsaw, Poland
Adrian Kłapyta is a doctoral student at Warsaw Medical University, formerly working at St. Jude, Inc. Other authors declare no conflict of interest. References1. Faggiano P, Antonini-Canterin F, Baldessin F, Lorusso R, D’Aloia A, Cas LD. Epidemiology and cardiovascular risk factors of aortic stenosis. Cardiovascular Ultrasound 2006; 4: 27.
2. Hopkins R, Louis J, Corcoran P. Ross’ first homograft replacement of the aortic valve. Ann Thorac Surg 1991; 52: 1190-1193.
3. Cremer J, Schöttler J, Petzina R, Hoffmann G. Stented bioprostheses in aortic position. HSR Proc Intensive Care Cardiovasc Anesth 2012; 4: 83-87.
4. Maruszewski B, Tobota Z, Zembala M, Sitko T. Report of the National Register of Cardiac Surgery KROK. Kardiochirur Torakochirur Pol 2012; 9: 283.
5. Schoen F, Levy R. Founder’s Award, 25th Annual Meeting of the Society for Biomaterials, perspectives. Providence, RI, April 28-May 2, 1999. Tissue heart valves: current challenges and future research perspectives. J Biomed Mater Res 1999; 47: 439-465.
6. Liao KK, Li X, John R, Amatya DM, Joyce LD, Park SJ, Bianco R, Bolman RM 3rd. Mechanical stress: An independent determinant of early bioprosthetic calcification in humans. Ann Thorac Surg 2008; 86: 491-495.
7. Bavaria J, Desai N, Burtch K, Vuong D, et al. Two-Year Results of the St. Jude Medical Trifecta Pericardial Aortic Valve Bioprosthesis. Presented at The Society for Heart Valve Disease, Barcelona, 2011.
8. Bavaria J, Szeto W, Burtch K, Moyer EP, Morris RJ, Desal NJ. Early Results of the St. Jude Medical Trifecta Pericardial Aortic Valve Bioprosthesis. Presented at the Heart Valve Society of America 6th Annual Scientific Session, New York 2010.
9. Trifecta Valve – 2011 Clinical Compendium, One Year Data. On-line: http://sjmcentral.sjm.com/sites/PRC/Resources/Trifecta
10. Dalmau MJ, María González-Santos J, López-Rodríguez J, Bueno M, Arribas A, Nieto F. One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study. Interact Cardiovasc Thorac Surg 2007; 6: 345-349.
11. Perez de Arenaza D, Lees B, Flather M, Nugara F, Husebye T, Jasinski M, Cisowski M, Khan M, Henein M, Gaer J, Guvendik L, Bochenek A, Wos S, Lie M, Van Nooten G, Pennell D, Pepper J; ASSERT (Aortic Stentless versus Stented valve assessed by Echocardiography Randomized Trial) Investigators. Randomized comparison of stentless versus stented valves for aortic stenosis: effects on left ventricular mass. Circulation 2005; 112: 2696-2702.
12. Dunning J, Graham RJ, Thambyrajah J, Stewart MJ, Kendall SW, Hunter S. Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial. Eur Heart J 2007; 8: 2369-2374.
13. Pillai R, Ratnatunga C, Soon JL, Kattach H, Khalil A, Jin XY. 3f Prosthesis Aortic Cusp Replacement: Implantation Technique and Early Results. Asian Cardiovasc Thorac Ann 2010; 18: 13-18.
Copyright: © 2013 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska). This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License ( http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
|
|