Do high-viscosity bulk-fill composites polymerize sufficiently at deep layers?

Firas Saddam Oglah Albaaj
1
,
Iqbal Alshalal
2
,
Mohammed Kassim Gholam
1

  1. College of Dentistry, Mustansiriyah University, Baghdad, Iraq
  2. Training and Workshops Center, University of Technology, Baghdad, Iraq
J Stoma 2023; 76, 1: 37-42
Online publish date: 2023/01/11
Article file
- JoS-00731.pdf  [0.17 MB]
Get citation
 
PlumX metrics:
 

INTRODUCTION

Even though composites present higher failure rates and increased risks of secondary caries development than amalgam [1], the trend for composite restoration placement in posterior teeth has increased dramatically in the last 10 years [2]. The photopolymerization process of light-cured composites forms a rigid cross-linked polymer matrix via reactivity of the monomer’s carbon double bonds [3]. However, some of these carbon bonds remain unreacted (unpolymerized) in the composite restoration [4]. Inadequate polymerization, also referred to as a low degree of conversion (DC) of monomer to polymer, substantially influences mechanical and physical properties of the composite, and decreasing the restoration’s surface micro-hardness [5]. In addition, low DC increases water sorption, solubility [6, 7], and composite discoloration [8].
Curing light intensity and DC decrease, as composite thickness increases [9, 10]. To overcome the consequen­ces of light attenuation and inadequate polymerization in deep posterior cavities, an incremental technique has been indicated. The method involves a maximum of a 2 mm thick increment and 40 seconds light curing time to achieve sufficient polymerization of composite restoration [11]. However, this technique can lengthen placement time and may increase treatment cost. Recently, manufacturers have developed high-viscosity bulk-fill composites, which could be placed in a single increment up to 4-5 mm thick. Manufacturers have claimed that these bulk-fill composites have the advantage of little attenuation effect on the transmitted curing light. Such an advantage may enable a sufficient DC at deep layers even with a shorter curing time (20 seconds). Therefore, the assessment of polymerization behaviors of new bulk-fill composites appears to be essential to guarantee their potential success in clinical applications.

OBJECTIVES

The aim of this in-vitro study was to estimate and compare the DC and micro-hardness (MH) of three commercially available bulk-fill composites at a 2-4 mm increment depth, following 20 and 40 seconds of light curing. The null hypothesis was that the two curing times produce no differences between DC or MH values of the tested composites.

MATERIAL AND METHODS

Three new brands of bulk-fill dental composite were selected for this study, including Beautifil-Bulk (Shofu Inc., Kyoto, Japan), Tetric N-Ceram Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein), and Opus Bulk Fill (FGM, Joinville, SC, Brazil) (Table 1). For each composite, uncured materials were inserted to slightly fill a cylindrical hole mold made of a silicon impression material. The mold comprised two halves of 2 mm height and 8 mm internal diameter assembled on top of each other. At first, the lower half was filled with a composite, followed by the upper half. Care was taken to avoid air entrapment during the composite placement. Three transparent polyester Mylar strips (0.05 mm thick) were placed on the top, bottom, and between mold halves to block the oxygen layer and create a smooth composite surface. The access composite was extruded using a glass slide with firm finger pressure on the top surface. The mold was then irradiated from the top surface (Figure 1) with a new light-emitting diode curing unit (Woodpecker, Guangxi, China) using standard curing mode (1,200 Mw/cm2). The tip of the light cure device was stabilized in direct contact on the Mylar strip. Six samples were prepared for each composite. Three samples were cured for 20 or 40 seconds according to sample grouping. After polymerization, the upper halves of the composite samples were discarded, whereas the lower halves were kept for study assessments. The lower halves were stored dry in a lightproof container at room temperature for one hour before assessments. For each composite, an uncured sample was used as a control for DC estimation.
A Fourier transform infrared spectrometer (FTIR, Bruker, Ettlingen, Germany) was applied to estimate DC. Each sample was mounted on FTIR stage, and an assessment was undertaken using the following setting: a wavelength of 500-4,000 cm-1, 32 scans, and a reso­lution of 6 cm-1. For cured and uncured samples, a ratio of absorbance spectrum peaks for the remaining aliphatic (C = C) and aromatic (C – C) carbon double bonds was estimated at 1,638 and 1,608 cm-1, respectively. DC percentage was then calculated using the following equation:
(1,638 cm-1/1,608 cm-1) cured sample
DC% = 1- x 100
(1,638 cm-1/1,608 cm-1) uncured sample
Following the DC test, the same samples were subjected immediately to surface MH test using Vickers hardness indenter (Laryee, Beijing, China). A diagonal diamond indenter was subjected to a fixed force of 300 g for a 15 s dual time. Three indentations at a 0.5 mm distance were created in the middle of the top and bottom surfaces. The mean Vickers hardness number of the three indentations was recorded as MH values for each surface. SPSS statistics version 21 software (IBM, Armonk, USA) was applied to analyze the data. Shapiro-Wilk test was used to investigate the normality of data distribution, and LSD test was used to compare the significance between means (p < 0.05). Spearman correlation test was applied to reveal the influence of DC% on MH of the top and bottom surfaces.

RESULTS

Data analyses with Shapiro-Wilk test showed that both DC% and MH were normally distributed around their statistical means. The mean DC% for the tested composites are listed in Table 2. Generally, the 40 seconds curing time produced higher DC% values compared with the 20 seconds curing time, but these differences were not significant (p ≥ 0.05). For both the curing times, Tetric N-Ceram composite showed the highest DC%, followed by Beautifil-Bulk and Opus Bulk Fill composites. The differences were statistically significant (Table 3), except for Beautifil-Bulk and Opus Bulk Fill, in which their results revealed non-significant differences (p ≥ 0.05).
The MH means of the top and bottom surfaces are presented in Table 4. Following 40 seconds light curing time, all the composites produced significantly higher MH values compared with 20 seconds light curing time. Among the composites, Beautifil-Bulk had the highest MH values of both surfaces, followed by Tetric N-Ceram and Opus Bulk Fill. The differences were significant, except for a non-significant difference found between the Beautifil-Bulk and Tetric N-Ceram top surfaces. In addition, the composites showed significantly higher MH values of the top surfaces than the bottom surfaces. However, for Beautifil-Bulk, the differences between the top and bottom surfaces were non-significant (Table 3).
Pearson r test revealed a significant (α = 0.042) positive correlation (r = 0.484) between DC and MH of the top surfaces, and a non-significant (α = 0.127) positive correlation (r = 0.374) between DC and MH of the bottom surfaces (Figure 2).

DISCUSSION

To simplify the placement procedure, dental companies produce different brands of high-viscosity bulk-fill composites. Companies have assumed that these composites can be placed in a single increment up to 5 mm thick using 20 seconds of curing light. Due to the limited translucency of composites, previous studies found that an increment of a maximum of 2 mm thick and a minimum of 40 seconds of irradiation time, are clinical requirements for conventional composite restorations [12, 13]. Therefore, the main challenge for the high-viscosity bulk-fill composites is achieving an effective polymerization at a depth greater than 2 mm for a shorter curing time.
This in-vitro study assessed DC% at deep layers of three current high-viscosity bulk-fill posterior composite materials irradiated for 20 and 40 seconds curing times. FTIR analytical tool was used to measure DC%, because this tool provides a direct measurement of the amount of unreacted carbon double bonds in polyme­rized composite [14]. Furthermore, the study also eva­luated the potential change in surface MH of composites relative to changes in DC.
Papadogiannis et al. suggested that a minimum conversion of 55% is required for the successful application of bulk-fill composites [15]. However, none of the tested composites achieved clinically accepted DC% for both curing times. This result agrees with findings of Jain et al. [16]. At deep layers, previous evidence was found of light attenuation that significantly affected the degree of conversion of particular bulk-fill composites [17, 18]. However, the present study results showed that a 40 se­conds curing time produced a significant improvement in DC% compared with 20 seconds curing time. This observation agrees with findings of Ajaj et al., who noted that extending the curing time may permit for more free carbon bonds to be involved in polymerization process [19].
Following 1-hour post-cure, the results of this study revealed a much lower DC% than other studies, which used a 24-hour post-cure time interval [17, 20]. Alshali et al. found that at 24 hours’ post-curing time, DC increased from 15-25% compared with immediately post-cure DC [21]. In the current study, Opus Bulk Fill had the lowest DC%, followed by Beautifil-Bulk, whereas Tetric-N Ceram had the highest DC%. The variation in monomer viscosities of the tested composites can be attributed to the differences in DC%. Monomers with higher viscosities, such as Bis-GMA, have a lower DC% than monomers with lower viscosities, including UDMA and TEGDMA [22, 23]. The low viscosity monomers have more flexible carbon bonds, which increase the monomer reactivity during photopolymerization [23]. Furthermore, the tested composites have different filler types and filler loads. Such differences in filler composition produce a variable influence on the amount of curing light passing through composite samples [24].
We found that extending the curing time from 20 to 40 seconds significantly improved the MH values on both surfaces. In addition, all tested composites showed low mean MH values on the bottom compared with top surfaces, particularly following 20 seconds hotopolymerization (MH range, 11.4-47.5). This observation is consistent with the results of de Mendonça et al. study [25]. The low MH values noted in the present work can be attributed to the low DC values. Previous findings showed that MH is a direct representation of DC [26, 27], because unreacted monomers can negatively affect the strength of composites, as confirmed by the positive correlation between DC and MH found in the current study. The Beautifil Bulk composite showed the highest mean MH values on both surfaces compared with the other two composites. Properties, such as translucency of composite material and matching of refractive indices between monomer and filler contents, positively affect DC and therefore, MH of composite samples [24]. Composites with high translucency and matched refractive indices produce little attenuation and scattering of the transmitted light through polymerizing composite [24, 28]. For clinical relevance, manufacturer claims are not accepted, and the tested high-viscosity bulk-fill composites are not recommended to be placed in a single increment restoration, which is 4 mm thick.

CONCLUSIONS

Following 1-hour post-cure, the tested composites showed insufficient DC and low surface hardness values at 2-4 mm depth when irradiated for 20 and 40 seconds. The extension of curing time to 40 seconds improved the DC and MH values. MH was positively affected by increasing the amount of DC. Tetric N-Ceram showed the highest DC values, whereas Beautifil-Bulk displayed the highest MH values. Moreover, Opus Bulk Fill presented the lowest DC and MH values.

CONFLICT OF INTEREST

The authors declare no potential conflict of interests with respect to the authorship and/or publication of this article.

References

1. Worthington HV, Khangura S, Seal K, et al. Direct composite resin fillings versus amalgam fillings for permanent posterior teeth. Cochrane Database Syst Rev 2021; 8: CD005620. doi: 10.1002/14651858.CD005620.pub3.
2. Alreshaid L, El-Badrawy W, Lawrence H, Santos M, Prakki A. Composite versus amalgam restorations placed in canadian dental schools. Oper Dent 2021; 46: 621-630.
3. Knobloch LA, Kerby RE, Clelland N, Lee J. Hardness and degree of conversion of posterior packable composites. Oper Dent 2004; 29: 642-649.
4. Kincses D, Böddi K, Őri Z, et al. Pre-heating effect on monomer elution and degree of conversion of contemporary and thermo­viscous bulk-fill resin-based dental composites. Polymers 2021; 13: 3599. doi: 10.3390/polym13203599.
5. Fanfoni L, De Biasi M, Antollovich G, Di Lenarda R, Angerame D. Evaluation of degree of conversion, rate of cure, microhardness, depth of cure, and contraction stress of new nanohybrid composites containing pre-polymerized spherical filler. J Mater Sci Mater Med 2020; 31: 127. doi: 10.1007/s10856-020-06464-9.
6. Matheel AR, Johari Y, Mohamad D, et al. Water sorption, solubility, degree of conversion, and surface hardness and topography of flowable composite utilizing nano silica from rice husk. J Mater Res Technol 2021; 15: 4173-4184.
7. Kılıç V, Hurmuzlu F, Ugur Y, Cangul S. Effect of layer thickness on residual monomer release in polymerization of bulk-fill composites. Polym and Polym Compos 2021; 29: S296-S305. doi: https://doi.org/10.1177/0967391121999588.
8. Alkhudhairy F, Vohra F, Naseem M, Owais MM, Amer AHB, Almutairi KB. Color stability and degree of conversion of a novel dibenzoyl germanium derivative containing photo-polymerized resin luting cement. J Appl Biomater Funct Mater 2020; 18: 2280800020917326. doi: 10.1177/2280800020917326.
9. Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology 2016; 104: 291-297.
10. Hasanain FA, Nassar HM, Ajaj RA. Effect of light curing distance on microhardness profiles of bulk-fill resin composites. Polymers (Basel) 2022; 14: 528. doi: 10.3390/polym14030528.
11. de Camargo EJ, Moreschi E, Baseggio W, Cury JA, Pascotto RC. Composite depth of cure using four polymerization techniques. J Appl Oral Sci 2009; 17: 446-450.
12. Lempel E, Őri Z, Kincses D, Lovász BV, Kunsági-Máté S, Szalma J. Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites. Dent Mate 2021; 37: 983-997.
13. Par M, Repusic I, Skenderovic H, Sever EK, Marovic D, Tarle Z. Real-time light transmittance monitoring for determining poly­merization completeness of conventional and bulk fill dental composites. Oper Dent 2018; 43: 19-31.
14. Stansbury J, Dickens SH. Determination of double bond conversion in dental resins by near infrared spectroscopy. Dent Mat 2001; 17: 71-79.
15. Papadogiannis D, Tolidis K, Gerasimou P, Lakes R, Papadogian-nis Y. Viscoelastic properties, creep behavior and degree of conversion of bulk fill composite resins. Dent Mat 2015; 31: 1533-1541.
16. Jain L, Mehta D, Meena N, Gupta R. Influence of light energy density, composite type, composite thickness, and postcuring phase on degree of conversion of bulk-fill composites. Contemp Clin Dent 2018; 9: S147.
17. Lee CI, Yi MD, Gage BM, Yarbrough LN, Kirkwood BJ, Lien W. Post-cure polymerization and depth-of-cure behaviors of dental bulk-fill resin-based composites. Med J (Ft Sam Houst Tex) 2021; PB 8-21-10/11/12: 74-82.
18. Gonçalves F, de Paiva Campos LM, Rodrigues-Júnior EC, et al. A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity. Braz Oral Res 2018; 32. E17. doi: 10.1590/1807-3107bor-2018.vol32.0017.
19. Ajaj RA, Yousef MK, El Naga AIA. Effect of different curing modes on the degree of conversion and the microhardness of different composite restorations. Dent Hypotheses 2015; 6: 109-116.
20. Ahmed D, Abd Al-jabar M. Effect of different storage temperatures on degree of polymerization of bulk fill composite resin – an in vitro study. Al-Rafidain Dent J 2022; 22: 194-202.
21. Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mat 2013; 29: e213-e217.
22. Leprince JG, Palin WM, Hadis MA, Devaux J, Leloup G. Progress in dimethacrylate-based dental composite technology and curing efficiency. Dent Mat 2013; 29: 139-56.
23. Sarosi C, Moldovan M, Soanca A, et al. Effects of monomer composition of urethane methacrylate based resins on the C=C degree of conversion, residual monomer content and mechanical properties. Polymers (Basel) 2021; 13: 4415. doi: 10.3390/polym13244415.
24. Fidalgo-Pereira R, Carpio D, Torres O, et al. The influence of inorganic fillers on the light transmission through resin-matrix composites during the light-curing procedure: an integrative review. Clin Oral Investig 2022; 26: 5575-5594.
25. de Mendonça BC, Soto-Montero JR, de Castro EF, et al. Effect of extended light activation and increment thickness on physical properties of conventional and bulk-filled resin-based composites. Clin Oral Investig 2022; 26: 3141-3150.
26. Marovic D, Panduric V, Tarle Z, et al. Degree of conversion and microhardness of dental composite resin materials. J Mol Struct 2013; 1044: 299-302.
27. Petronijevic Sarcev B, Balos S, Markovic D, et al. Effect of the degree of conversion on mechanical properties and monomer elution from self-, dual-and light-cured core composites. Materials (Basel) 2021; 14: 5642. doi: 10.3390/ma14195642.
28. Supornpun N, Oster M, Phasuk K, Chu T-MG. Effects of shade and thickness on the translucency parameter of anatomic-contour zirconia, transmitted light intensity, and degree of conversion of the resin cement. J Prosthet Dent 2021; S0022-3913(21)00251-1. doi: 10.1016/j.prosdent.2021.04.019.
This is an Open Access journal, all articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.