Current issue
Archive
Videos
Articles in press
About the journal
Supplements
Editorial board
Reviewers
Abstracting and indexing
Subscription
Contact
Instructions for authors
Publication charge
Ethical standards and procedures
Editorial System
Submit your Manuscript
|
4/2011
vol. 113 abstract:
Original paper
Evaluation of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and standard phacoemulsification through 2.75 mm incision
Michal Wilczynski
1
,
Ewa Supady
1
,
Piotr Loba
1
,
Aleksandra Synder
1
,
Dorota Palenga-Pydyn
1
,
Wojciech Omulecki
1
Klinika Oczna 2011, 113 (4): 314-320
Online publish date: 2011/12/04
View
full text
Get citation
ENW EndNote
BIB JabRef, Mendeley
RIS Papers, Reference Manager, RefWorks, Zotero
AMA
APA
Chicago
Harvard
MLA
Vancouver
Introduction
Improvements in technology connected with cataract surgery have made it possible to decrease significantly the size of corneal incision created during phacoemulsification. Recently, coaxial phacoemulsification through a 1.8 mm microincision (C-MICS) has been introduced. This technique is perceived as the next step in development of phacoemulsification. Purpose: To compare surgically induced astigmatism (SIA) after coaxial 1.8 mm microincision cataract surgery (C-MICS) and standard phacoemulsification through 2.75 mm incision, calculated with three mathematical methods. Material and methods A consecutive, prospective series of 55 eyes of 55 patients who underwent uneventful C-MICS with foldable IOL implantation using 1.8 mm temporal clear corneal incision were included in group 1. Reference group (group 2) included 55 eyes of 55 patients who underwent uneventful phacoemulsification through 2.75 mm temporal clear corneal incision with a foldable IOL implantation. SIA was calculated using three methods. Results All patients had uneventful surgery and were examined before the surgery and one month postoperatively. There was a significant postoperative increase in corrected distance visual acuity in both groups (p<0.01), and the visual outcomes in both groups were similar (p>0.05). In vector analysis, mean SIA was 0.42 ± 0.30 in group 1 and 0.77 ± 0.55 in group 2. In vector decomposition, the mean SIA (C90) in group 1 was 0.24 ± 0.29 and 0.49 ± 0.54 in group 2 (p<0.05). In Naeser’s polar values method, ΔKP-0 was -0.06 ± 0.43 in group 1 and -0.21 ± 0.84 in group 2 (p>0.05). Conclusions 1.8 mm coaxial MICS induces a significantly smaller value of SIA than standard 2.75 mm phacoemulsification. keywords:
Surgically induced astigmatism, microincision, coaxial MICS, standard phacoemulsification |
|