twitter
en POLSKI
eISSN: 2719-3209
ISSN: 0023-2157
Klinika Oczna / Acta Ophthalmologica Polonica
Current issue Archive Videos Articles in press About the journal Supplements Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2005
vol. 107
 
Share:
Share:
abstract:
Experimental research

Flicker­ Perimetry­ (CFF)­ in ­patients­ with ­lens­ opacities­ - ­first ­report

Re­na­ta­ Ki­nasz
1
,
Iza­be­la Za­woj­ska
1
,
An­drzej­ Du­dziń­ski
1
,
Do­ro­ta Wy­glę­dow­ska­-Pr­omie­ńska
1

  1. Katedra i Klinika Okulistyki Śląskiej Akademii Medycznej w Katowicach
Klinika Oczna 2005, 107(1-3): 31-35
Online publish date: 2005/03/15
View full text Get citation
 
Introduction
Comparison of standard W/W and CFF perimetry in patients with cataract and lens opacities.

Material and methods
Visual field was measured on Octopus 301 perimeter with option „flicker perimetry”. W/W and CFF perimetry (Program G1 in TOP strategy) was performed in 44 eyes with cataract and lens opacities.

Results
Defects in visual field with CFF perimetry were found in 24% of cases but with W/W perimetry in 100% of cases.

Conclusions
Perimetry CFF is a new tool for early detection and follow up of visual field defects in patients with cataract and lens opacities.

keywords:

visual field, CFF perimetry, cataract

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.