eISSN: 2299-0054
ISSN: 1895-4588
Videosurgery and Other Miniinvasive Techniques
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2009
vol. 4
 
Share:
Share:
Original paper

Influence of operative technique on recurrence rate in Lichtenstein hernioplasty using partially absorbable lightweight mesh

Polish Hernia Study Group

Videosurgery and other miniinvasive techniques 2009; 4 (1): 10–15
Online publish date: 2009/03/27
Article file
- 03_Influence.pdf  [0.11 MB]
Get citation
 
 
Introduction
A unified theory of hernia formation based on experimental and clinical studies on aetiology was published by Bendavid in 2005. According to a concept of congenital metabolic anomalies in connective tissue, hernia seems to be a manifestation of systemic collagen disease [1]. Understanding the mechanisms of hernia formation also has clinical implications. Tension methods widely applied in the 20th century seem insufficient, as they employed deficient host tissue to reinforce the posterior wall of the inguinal canal. Amid has stated that, as he understands this theory, not to use the mesh in hernioplasty is against basic rules of surgery [2]. The theoretical superiority of mesh hernioplasty was confirmed in a meta- analysis of the EU Hernia Trialists Collaboration conducted during 1999-2002 [3]. In the last decades of the 20th century many tension-free methods were described and numerous synthetic implants were introduced to the market, yet Lichtenstein hernioplasty is accepted as a “gold standard” and is most frequently employed and assessed in clinical trials. Recently this method has also been recommended in national standards in the UK, the Netherlands, USA and Poland [4-7]. Mechanical characteristics and inflammatory reaction caused by implants applied in hernia repair are extensively discussed in the literature. Targeted to decrease acute and chronic postoperative pain in the groin, minimization of mesh weight has led to the invention of lightweight and composite meshes. In some clinical studies however, increased recurrence rate up to 5% was noted [8, 9]. The authors concluded that this group of meshes, due to their mechanical values, may call for a different implantation technique [9]. This paper gives a detailed description of a modified Lichtenstein technique for composite mesh implantation and addresses its influence on recurrence rate.

Material and methods
Between 2002 and 2004, six hundred patients were evaluated and randomized in the trial. Patients 20-75 years old, diagnosed with primary inguinal hernia were eligible to participate in the study. Patients were recruited and operated on in 15 hospitals in Poland (12 regional and 3 univer-sity-based). All patients gave their informed consent. The study was approved by the Ethical Committee of the Medical University of Gdansk for all the participating centres, in accordance with Polish legal regulations. Patients were followed for two years on six in- and outpatient visits (hospital stay, 7 days, 3 and 6 months, one and two years). Hernia characteristics and timing of its occurrence were assessed before surgery. All visits were conducted in a hospital-based setting. Post-operative physical examination was done by a blinded surgeon who was not involved in the surgery. Recurrence was a primary endpoint of the study and was diagnosed on physical examination performed by a surgeon blinded to the type of mesh used. Presence of recurrence was assessed on every visit scheduled in the study flow chart. Additionally, during the hospital stay and until 3 months later, data on perioperative complications (haematoma, seroma, nerve damage), urinary retention, need for urinary catheter placement and wound infection rate were collected. Three months after the randomization had ended, audit visits in all centres were conducted by the supervising committee members. Data were double checked: case report files vs. hospital documentation and vs. random patient’s personal reports (visits or telephone interview). In cases of a serious violation of study protocol, e.g. uncompleted CRFs (for reasons other than loss from follow-up) or where incompatibility of the data exceeded 1% (identification of patients not possible, patient does not confirm control visits, lost or lacking original hospital documentation, loss of patient’s entire documentation or doubts about the blinding and/or randomization process) the centre was excluded from the trial. In those cases, all of the CRFs from a given hospital were not taken into consideration and were excluded from statistical analysis. Disapproval of the whole centre’s documentation was chosen to avoid bias in the trial and in statistical analysis. After audit visits, seven hospitals (208 patients) were excluded from the study.

Operative technique
An operative technique based on the description by Amid was applied [2]. Briefly, the hernia sac was explored and invaginated into the abdominal cavity without opening. Only large scrotal hernia or incarceration with suspicion of ischaemic bowel required opening, ligation and dissection of the hernia sac. All three nerves in the inguinal canal were identified and thoroughly preserved, and the cremaster muscle was not resected. In the control group, a heavyweight polypropylene mesh was implanted (PROLENE, Ethicon GMbH, Hamburg, Germany). In the study group, a lightweight partially absorbable mesh of 7.5 ´ 15 cm composed from poliglecaprone and polypropylene (Ultraproâ, Ethicon GMbH, Hamburg, Germany) was used for the repair. Due to the absorption of poliglecaprone, the mesh weight decreases by about 50% in 3 months. We noticed that after shaping the mesh, the pores on the margins seemed to be closed (Figure 1). Suturing and extension can unravel such pores and rip the suture. These findings, and characteristic mesh elasticity, led us to implement three suturing modifications to the basic Lichtenstein technique. A larger suture margin (minimum four pores of mesh) and about half the distance between ‘steps’ (maximum 1 cm) were used for running sutures on the inguinal ligament. An extra suture was placed to fix the mesh bone between the pubic tubercle and the middle line to prevent mesh overlap from protruding above the pubic bone.

Statistical analysis
Statistical calculations were performed using Statistica 7.1 PL (Polish version) software (StatSoft, Inc, Tulsa, USA). Descriptive statistics were used for characterization of patient groups; mean (standard deviation) or median values (range of values) were given, depending on the type of data and their normal distribution on the interval scale. Normal distribution was verified with the Shapiro-Wilk W test. The data were compared using Student’s t-test or the Mann Whitney U test as appropriate. Repeated mea-surements were analyzed using a two-way ANOVA test for repeated measurements, with following analysis of significant differences using the post-hoc method (Tukey’s HSD test) when appropriate. Categorical data are presented as percentage values and 95% confidence intervals and compared using a c2 test, with Yates correction when necessary. The significance level of p < 0.05 was adopted.

Results
After the internal audit, of all randomized patients 215 in the Ultrapro (UP) group and 177 in the polypropylene (PP) group were included in the trial database. Randomization data for both groups are presented in Table I. No statistical differences between the groups were seen. Of these patients, 3, 6, 12 and 24-month follow-ups were reached by 100%, 98.02% (4 patients lost), 97.8% (12 patients lost) and 97.8% respectively. The incidence of recurrence was slightly higher in the UP group (1.86%) than in the PP group (0.56%), but statistical significance was not achieved (p = 0.493). All recurrences occurred solely in male patients. Analysis of recurrence location showed no correlation of hernia type and site of recurrence. In 3 patients recurrence happened after direct hernia repair (Rutkow type 4) and in 2 after indirect one (Rutkow type 2). In all recurrent cases no local complications or other factors which might have promoted recurrence (concomitant diseases) were present. In most patients, recurrence was found between the pubic bone at the mesh margin. Intraoperatively too small margin of the mesh on the pubic bone (2 cases) or mesh lifted from the bone (2 cases) were found. In one case from the UP group, recurrence occurred at the site of the deep inguinal ring through insufficient mesh closure. A detailed description of patients with recurrence is summarized in Table II.

Discussion
The introduction of tension-free methods in recent decades has revolutionized inguinal hernia repair so profoundly that new evaluation methods were needed to properly assess the results of the treatment. Traditionally in tension methods, due to long convalescence and difficult operative technique, recurrence rate was the usual primary endpoint of treatment and was seen in more than 10% of patients [10]. Introduction of the synthetic mesh decreased the recurrence rate to 1-3% [3]. Yet, some observations published in recent years demonstrated that implanted mesh causes a chronic inflammatory reaction [11]. Additionally, dense heavyweight poly-propylene mesh creates a firm scar, a non-elastic structure surrounded by connective tissue, shrinking in the late postoperative period [12]. To solve this problem, large-pore lightweight meshes were introduced to clinical practice. Experimental studies confirmed decreased inflammatory reaction and showed the spatial character of the scar. A soft scar should theoretically decrease the foreign body sensation and pain in the groin. Less mesh shrinkage should also prevent recurrence [12]. Lately, clinical trials were conducted to confirm the theoretical advantage of lightweight implants in inguinal hernioplasty. Some investigators in prospective randomized studies comparing lightweight with heavyweight mesh have observed decreased pain. However, another two studies could not confirm this observation [6, 7, 12]. Moreover, potentially increased risk of recurrence (over 5%) was noted for partially absorbable mesh (Vypro II) in one study [6]. These results clearly do not match many other cohort studies of heavyweight mesh in the Lichtenstein technique, which constantly reported recurrence rate of less than 1% even in 5-year follow-up [3, 13-15]. The authors of the study suspected that lightweight mesh elasticity might affect recurrence and recommended a modification of the implantation technique [9]. In our study, we applied additional sutures to avoid recurrence, but still this modification does not affect the classical Lichtenstein repair procedure and does not change its principles. Additional sutures were not applied in the proximity of the nerves; thus they should not influence post-operative pain either. Elasticity of the mesh requires additional fixation on the pubic tubercle and allows flat implantation (without dome-shaped relaxation). Suture margin on the inguinal ligament was a consequence of mesh properties noticed while cutting the mesh edges (unravelled pores). In this modified suturing technique, mesh will be folded on the margin but in our opinion large pores and flexibility of the material should prevent “dead space” formation. During two years’ follow-up we did not observe any late infections or purulent fistulas in the UP group, which seems to confirm this hypothesis.
In the presented study the recurrence rate was higher in the Ultrapro group, although a statistical difference was not achieved. This supports our hypothesis that the modification we applied prevents early recurrence biased by the operative technique. The recurrences seen in the study occurred in the area of the pubic tubercle, which corresponds with the results noted by other authors [16]. Whether recurrence is caused by deficiency of surgical technique (too small mesh margin) or by material properties is a question that definitely calls for consideration. Further observation, planed for 5 years, will answer the question of influence of the material on late recurrence rate. So far, introduced modification of the operative technique did not increase the recurrence rate and the results are comparable with other published cohorts. The described modification was also used to create the guidelines (Table III) for centres involved in the trial and is now used routinely, which should enable it to be assessed in large clinical material in the near future.

Acknowledgments
The authors thank Andrzej Floriańczyk for support of the study idea. The study was supported by a minor grant by Ethicon Poland to cover the costs of workshops and trialists’ meetings. Neither physicians nor patients were reimbursed. None of the authors has any direct or indirect financial interest in the product.

References
1. Bendawid R. The unified theory of hernia formation. Hernia 2004; 8: 171-6.
2. Amid P. Lichtenstein tension-free hernioplasty: Its inception, evolution and principles. Hernia 2004; 8: 1-7.
3. EU Hernia Trialists Collaboration. Mesh compared with non-mesh methods of open groin hernia repair: systematic review of randomized controlled trials. Br J Surg 2000; 87: 845-59.
4. SimonsMP. “Richtlijn Behandeling van de liesbreuk” Commissie Richtlijn Liesbreuk Netherlands 2003. Available at: (online) www.richtlijnonline.nl.
5. Metzger J, Lutz N, Laidlaw I. Guidelines for inguinal hernia repair in everyday practice. Ann R Coll Surg Engl 2001; 83: 209-14.
6. Smietañski M, Bigda J (ed). Polski Standard Leczenia Przepuklin Pachwiny. Wydawnictwo AMG, Gdañsk 2003.
7. Kingsnorth A. PIER. Hernia. Available at: www.pier.acponline.org/ physisians/diseases/d107/d107.html.
8. Post S, Weiss B, Willer M, et al. Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 2004; 91: 44-8.
9. O’Dwyer PJ, Kingsnorth AN, Molloy RG, et al. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 2005; 92: 166-70.
10. Jess P, Hauge C, Hansen CR. Long-term results of repair of the internal ring for primary inguinal hernia. Eur J Surg 1999; 165: 748-50.
11. Klinge U, Klosterhalfen B, Muller M, Schumpelick V. Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 1999; 165: 665-73.
12. Cobb WS, Kercher KW, Heniford BT. The argument for lightweight polypropylene mesh in hernia repair. Surg Innovation 2005; 12: 63-9.
13. Butters M, Radecke J, Koeninger J. Long-term results of a randomized clinical trial of Shouldice, Lichtenstein and transabdominal preperitoneal hernia repairs. Br J Surg 2007; 94: 562-5.
14. Bisgard T, Bay-Nielsen M, Christensen IJ, Kehlet H. Risk of recurrence 5 years or more after primary Lichtenstein mesh and sutured inguinal hernia repair. Br J Surg 2007; 94: 1038-49.
15. Bay-Nielsem M, Kehlet H, Strand L, et al. Quality assessment of 26304 herniorrhapies in Denmark: a prospective nationwide study. Lancet 2001; 358: 1124-8.
16. Amid P. The Lichtenstein repair in 2002: an overview of causes of recurrence after Lichtenstein tension-free hernioplasty. Hernia 2003; 7: 13-6.

Appendix:
The Polish Hernia Study Group consists of:
• project leader – Śmietański M (Gdańsk),
• steering – Bigda J (Gdańsk), Łukasiewicz J (Gdańsk), Łukiański M (Gdańsk), Witkowski P (New York, USA),
• scientific advisory board – Matyja A (Kraków), Śledziński Z (Gdańsk), Śmietańska IA (consultant in anaesthesiology, Gdańsk), Owczuk R (consultant statistician, Gdańsk),
• trialists – Bierca J (Warszawa), Bury K (Gdańsk), Dideńko W (Warszawa), Gąsiorowski A (Zgorzelec), Gebuza A (Wrocław), Gumela P (Gdańsk), Jędrasiak D (Warszawa), Kamiński Z (Biała Podlaska), Kątny T (Bydgoszcz), Kniaź M (Wrocław), Kostewicz W (Warszawa), Kurzyński M (Zgorzelec), Kwiatkowski A (Warszawa), Leszczyszyn J (Wrocław), Łebski I (Wrocław), Malińska K (Środa Wlkp.), Mazur A (Kędzierzyn-Koźle), Olejarz A (Bydgoszcz), Orłowski P (Warszawa), Paradowski T (Bydgoszcz), Paśko K (Wrocław), Perczyński W (Warszawa), Piotrowski R (Koszalin), Ryll P (Środa Wlkp.), Sachanbinski T (Opole), Sawicki M (Warszawa), Skoczylas M (Wrocław), Solecki R (Kraków), Szczepanowski A (Kędzierzyn-Koźle), Timler D (Łodź), Trojanowski P (Warszawa), Wiśniewski W (Warszawa).
Copyright: © 2009 Fundacja Videochirurgii This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
  
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.