3/2014
vol. 9
Short communication
Interactive 3D imaging technologies: application in advanced methods of jaw bone reconstruction using stem cells/
pre-osteoblasts in oral surgery
Videosurgery Miniinv 2014; 9 (3): 441–448
Online publish date: 2014/05/29
Get citation
PlumX metrics:
Introduction
The inventor of digital radiography, Dr Francis Mouyen, used to say that a dentist without radiological diagnosis is like a luxury car driver with his eyes covered [1]. At present, it is difficult to imagine comprehensive treatment planning without considering radiological diagnosis [2–8]. Single dental X-rays, panoramic images and cephalometric radiographs until recently represented the standard of treatment planning in the maxillofacial area. The main disadvantage of these images is their 2-dimensionality. Cone beam computed tomography (CBCT), also known as digital volumetric tomography, was developed in the late 1990s and has proved to be a useful tool in many aspects of oral and maxillofacial surgery as well as in implant dentistry [3]. Due to the fact that it is a 3-dimensional examination it excludes the problem of overlapping anatomical structures, as in the case of conventional 2-dimensional radiography. During the examination the arm rotates around the patient’s head by performing a series of projections. Data obtained during one rotation of the device in less than 1 minute allow one to obtain images that formerly required the implementation of a number of X-rays. Detectors record images of various parts resulting in a 3-dimensional image that can be processed in an infinite number of ways. Dental cone beam scans offer invaluable information about maxillofacial structures and are currently used in all fields of dentistry including endodontics and orthodontics. Currently produced CBCT scanners seek to eliminate the radiation dose absorbed by the patient during the test.
Cone beam computed tomography has created a specific revolution in maxillofacial imaging, facilitating the transition of dental diagnosis from 2D to 3D, and expanded the role of imaging from diagnosis to the possibility of actual planning. There are many varieties of CBCT related software available, from basic DICOM viewers to very advanced planning modules, such as InVivo Anatomage, and SimPlant (Materialise Dental). Through the use of these programs scans could be processed into 3-dimensional high-quality simulation, which enables one to plan the overall treatment.
Aim
In this article methods of visualization are demonstrated and compared, in the example of advanced cases of jaw bone defect reconstruction using tissue engineering.
Material and methods
Three-dimensional radiological diagnosis was performed in the Department of Oral Surgery, Medical University of Warsaw among 30 patients treated due to large jaw bone defects of different etiology. Interactive visualization technologies were used during planning and monitoring a novel method of bone defect treatment consisting of an advanced method of tissue engineering (allogenic bone blocks infiltrated with autologous pre-osteoblasts proliferated and differentiated in vitro (4-week culture) from stem cells taken from the bone marrow aspiration biopsy). The procedure was applied in generally healthy patients (detailed inclusion/exclusion criteria). In each case CBCT (Gendex) was performed to visualize the shape and length of the bone defect in order to achieve precise treatment planning and preparation of an adequate bone graft by using piezosurgery (Mectron Piezosurgery Touch) and rotation saws (W&H). Allogenic bone blocks were prepared according to the standards at the Central Tissue Bank, MUW. The CBCT data were subsequently processed through InVivo Anatomage and SimPlant (Materialise Dental) software. In the first stage the data obtained from classical CBCT, InVivo Dental Anatomage and SimPlant (Materialise Dental) were used for preliminary diagnosis of bone defects, planning of the complex treatment and selecting the surgical approach. At a later phase of treatment scans and 3D visualizations enabled control of graft remodeling, its incorporation to the recipient bone site and assessment of early mineralization sites at the present scaffold. In cases requiring tooth replacement advanced 3-dimensional imaging software enabled simulation of dental implant installation. A description of the procedures is presented below in the example of two different bone defects.
Congenital bone defect – deficient quantity of bone accompanying congenital lack of lower central incisors
Congenital absence of upper lateral incisors was recently compensated orthodontically, when the place for implants in the midline of the lower jaw was prepared. The CBCT scans (Gendex) revealed insufficient residual bone volume in the area of lower central incisors for implant placement (Photo 1). For more detailed assessment of quality and quantity of the alveolar bone a 3D visualization was done using InVivo Anatomage (Photo 2) and SimPlant (Materialise Dental) software (Photo 3). Based on a detailed analysis of the images bone augmentation was planned before the installation of dental implants. The congenital bone defect was filled with the graft (allogenic bone block + 40 × 106 pre-osteoblasts) and stabilized by 2 micro-screws (Medartis). Control CBCT was performed to visualize the graft (Photo 4). For better imaging, scans were converted and 3D reconstructions were performed (Photos 5, 6). Early implant placement was planned using InVivo and SimPlant programs (Photos 7, 8).
Post-cystectomy bone defect – periapical cyst located in the anterior part of the maxilla
The CBCT (Gendex) scans showed an osteolytic defect extending from the upper right central incisor to the upper left canine through the width of the maxilla from the buccal to the palatal site (Photo 9). The surgical bone defect treatment was planned using the methodology described above. The cyst was completely removed. Root resection of left upper incisors was performed. The bone defect was filled with allogenic bone block, which was ex tempore saturated with autologic preosteoblasts and then fixed with a miniplate for osteosynthesis (Medartis). Control CBCT was performed to visualize the graft. For more accurate imaging scans were converted and 3D reconstructions were performed (Photos 10, 11).
Results
Application of 3-dimensional imaging technologies (InVivo Anatomage, SimPlant (Materialise) have enabled wide and precise diagnosis, reducing operative time, possibility of monitoring the patients treated using advanced methods of tissue engineering, early implant treatment planning and consequently higher operator self-confidence and greater safety for the patient.
Discussion
Implant treatment has become increasingly popular and accessible [9–12]. One of the basic conditions for successful implant rehabilitation is an adequate alveolar bone base. In practice, frequently observed deficient bone quantity becomes a challenge for the surgeon. The most precise method allowing an accurate assessment of osseous conditions is 3-dimensional computed tomography. The examination enables the detection of various bone defects, such as age-related atrophies, pathological lesions, injuries, congenital disorders and systemic diseases. In many cases, these defects could not be detected or adequately diagnosed on conventional 2D radiographs. The alveolar bone quantity influences a number of factors in the overall implant treatment plan: bone augmentation, implant type, implant length, and implant installation angle [9]. Assessment of the quality of the bone comprises the thickness of cortical bone and characteristics of trabecular bones, which is an important factor because it contributes to implant stability [13–19]. Modern 3-dimensional visualization software allows in addition spatial evaluation of maxillofacial structures and virtual installation of dental implants. Such a pre-surgical procedure allows for the later noninvasive installation of dental implants in the appropriate place without damaging the anatomical structures. Furthermore, 3D visualization is a useful tool to explain and illustrate the treatment plan to the patient. A visible image of the planned rehabilitation raises the patient’s confidence and benefits the patient-doctor cooperation [20, 21].
InVivo Anatomage and SimPlant (Materialise) programs are useful tools in monitoring patients after treatment of jaw bone defects using tissue engineering techniques. In the presented method allogenic bone blocks are highly visible on the controlled scans and exhibit characteristics of incorporation into residual bone. InVivo Dental Anatomage is easy to use and quickly visualizes transparent hard tissue, detailed bone profile, soft tissues, sinus anatomy, airways and skin profiles. The program offers fast implant planning, after which a dynamic simulation of the virtual surgery could be played in front of the patient. Additionally, these simulations can be captured as videos and saved for records or used at subsequent appointments.
The SimPlant software allows a precise assessment of the patient anatomical structures and allows one to simulate implant placement and bone augmentation procedures. It provides an esthetic visualization of the implants. The program offers a library with more than 8000 different implants and abutments, a 3D transparency tool for investigation of the position of the nerve towards the implants, and precise assessment of bone density.
Conclusions
Modern, interactive visualization software allows one to precisely plan the treatment, to control its course and to specify its effects. Programs such as InVivo Anatomage and SimPlant (Materialise) are useful tools in comprehensive treatment of the maxillofacial area.
References
1. Grochowina A. Rentgenodiagnostyka w endodoncji. In: Współczesna endodoncja w praktyce. Arabska-Przedpełska A, Pawlicka H. Bestom DENTOnet.pl, Łódź 2011; 107-26.
2. Frank S, Jodko M, Wojtowicz A. Comparative assessment of primary dental implant stability. Dental Forum 2012; 1: 75-81.
3. Horner K, Jacobs R, Schulze R. Dental CBCT equipment and performance issues. Radiation Protection Dosimetry 2013; 153: 212-8.
4. Hatcher DC. Operational principles for cone-beam computed tomography. JADA 2010; 141 (Suppl 3): 3-6.
5. Scarfe WC, Allan G, Farman AG. What is cone-beam CT and how does it work? Dent Clin N Am 2008; 52: 707-30.
6. Wang WH, Zhu J, Deng JY, et al. Three-dimensional virtual technology in reconstruction of mandibular defect including condyle using double-barrel vascularized fibula flap. J Craniomaxillofac Surg 2013; 41: 417-22.
7. Hu KS, Choi DY, Lee WJ, et al. Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers. J Periodontal Implant Sci 2012; 42: 39-44.
8. Roberts JA, Drage NA, Davies J, Thomas DW. Effective dose from cone beam CT examinations in dentistry. Br J Radiol 2009; 82: 35-40.
9. Frei C, Buser D, Dula K. Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry. Clin Oral Implants Res 2004; 15: 490-7.
10. Tyndall DA, Brooks SL. Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology. Oral Surg Oral Med. Oral Pathol Oral Radiol Endod 2000; 89: 630-7.
11. Hanazawa T, Sano T, Seki K, Okano T. Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Implants Res 2004; 15: 226-32.
12. Al-Ekrish AA, Ekram M. A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011; 40: 67-75.
13. Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implants 2004; 19: 228-31.
14. Van de Velde T, Glor F, De Bruyn H. A model study on flapless implant placement by clinicians with a different experience level in implant surgery. Clin Oral Implants Res 2008; 19: 66-72.
15. Kaing L, Grubor D, Chandu A. Assessment of bone grafts placed within an oral and maxillofacial training programme for implant rehabilitation. Austral Dental J 2011; 56: 406-11.
16. Tonelli P, Duvina M, Barbato L, et al. Bone regeneration in dentistry. Clin Cases Miner Bone Metab 2011; 8: 24-8.
17. Suomalainen A, Vehmas T, Kortesniemi M, et al. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 2008; 37: 10-7.
18. Kim KD, Jeong HG, Choi SH, et al. Effect of mandibular positioning on preimplant site measurement of the mandible in reformatted CT. Int J Periodontics Restorative Dent 2003; 23: 177-83.
19. Sforza NM, Franchini F, Lamma A, et al. Accuracy of computed tomography for the evaluation of mandibular sites prior to implant placement. Int J Periodontics Restorative Dent 2007; 27: 589-95.
20. Cavalcanti MG, Haller JW, Vannier MW. Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: experimental validation in vitro. J Oral Maxillofac Surg 1999; 57: 690-4.
21. Araki K, Maki K, Seki K, et al. Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties. Dentomaxillofac Radiol 2004; 33: 51-9.
Received: 11.12.2013, accepted: 26.01.2014.
Copyright: © 2014 Fundacja Videochirurgii This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
|
|