eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
4/2018
vol. 14
 
Share:
Share:
Original paper

Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation

Sebastian Góreczny
,
Paweł Dryżek
,
Tomasz Moszura
,
Maciej Łukaszewski
,
Michał Podgórski
,
Sarah Nordmeyer
,
Titus Kuehne
,
Felix Berger
,
Stephan Schubert

Adv Interv Cardiol 2018; 14, 4 (54): 413–421
Online publish date: 2018/12/11
Article file
- magnetic.pdf  [0.30 MB]
Get citation
 
 

Summary

Until recently two-dimensional (2D) angiography was the mainstay guidance of percutaneous pulmonary valve implantation (PPVI). Introduction of three-dimensional rotational angiography enabled utilization of three-dimensional (3D) reconstruction to exclude coronary compression during balloon testing and/or to guide stent/valve placement. However, the specific C-arm setup and the need to process the three-dimensional dataset during the study may increase the procedure length. Direct 2D–3D fusion of pre-registered magnetic resonance (MR) or computed tomography (CT) datasets allows for shortening of the diagnostic phase of the procedure and facilitates PPVI. Initial data show that utilization of CT-derived roadmaps may lead to lower contrast exposure and shorter procedural time, whereas application of MRI datasets may lead to lower radiation exposure.

Introduction

Over the recent years percutaneous pulmonary valve implantation (PPVI) has dramatically gained in popularity [1–3]. Promising results in patients with dysfunctional surgically placed grafts encouraged application of this treatment in those with native or patched right ventricular outflow tracts (RVOT) [4–7].
Moreover, new devices and refined techniques of implantation have been introduced to extend PPVI to patients previously deemed unsuitable [8, 9]. Despite these improvements, several potentially fatal complications, such as coronary artery compression, conduit rupture, valve or stent dislocation, are inherent to this treatment and require extensive pre- and intra-procedural imaging [10–12]. Attempts have been made to select patients at risk of complications on the basis of non-invasive imaging; however, until recently two-dimensional (2D) angiography was the mainstay of procedural guidance [1–14]. Even in typical cases, this technique requires repeated contrast administration to visualize the RVOT and pulmonary arteries, in order to position the stent(s) for a “landing zone” (pre-stenting) as well as assess the outcome. Multiplane visualization of the coronary arteries is indispensable before and during expansion of the “landing zone” particularly to rule out coronary compression. This relies on multiple filmed projections used to identify the left or right coronary course, which increases radiation and examination time. Introduction of three-dimensional rotational angiography (3DRA) has enabled the three-dimensional (3D) reconstruction to exclude coronary compression during simultaneous balloon testing and/or to guide stent/valve placement [15]. In the past, exposure to a relatively large contrast volume and higher radiation was the major drawback of this imaging modality. However, with use of modified study protocols and optimization of imaging settings the degree of exposure has been alleviated to some extent [16–18]. Unfortunately, the specific C-arm setup and the need to process the 3D dataset during the study may increase the procedure length.
Recent advances in fusion software have enabled easy application of pre-intervention imaging, including computed tomography (CT) and magnetic resonance imaging (MRI) scans, to create a reliable roadmap for manipulating through complex cardiac anatomy [19–22]. This strategy has the potential to reduce the need for diagnostic angiographies while providing reliable guidance of stent/valve implantation without the need for repeated contrast injections. Moreover, it promises improvement of visualization, as well as a reduction of total contrast and radiation exposure.

Aim

In this report we describe an initial 9-month, two-center experience with novel image fusion software for live guidance of PPVI with MRI- and CT-derived 3D roadmaps.

Material and methods

We have performed a prospective study of PPVIs guided with VesselNavigator (Philips Healthcare) at two reference centers since its introduction in the last quarter of 2015. Inclusion criteria were as follows: availability of cardiac CT or MRI dataset, which was performed for clinical purposes only and according to the centre’s or external radiology protocol, and use of VesselNavigator with integration of the CT or MRI dataset. Table I presents collected data according to the study protocol.
Application of VesselNavigator included four steps: segmentation, planning, registration and live guidance (Figure 1) [23]. DICOM data from the contrast CT or the 3D whole heart or angiographic sequence MRI were uploaded into the VesselNavigator (Figure 2). The 3D image fusion software had been installed into the Allura XPer or Clarity (Philips Healthcare) platform on a separate computer. Segmentation of desired vessels was performed by highlighting and selecting the structures on automatically created 3D reconstructions or on one of the three orthogonal planes. The next steps consisted of placing marking rings/points, performing measurements and selecting the best angulations for the planned intervention.
The final stage before live guidance, and the first step requiring the patient to be prepared in the catheterization laboratory, is fusion of live fluoroscopy and the 3D roadmap. This is possible with 3D–3D or, a unique feature of this software, direct 2D–3D registration. The former requires a 3D data set derived from rotational spin, whereas the latter utilizes internal markers or 2D angiography as a reference.
Internal markers are mostly used for fusion of CT-derived 3D roadmaps. Easily visible bony structures such as the spine, vertebrae and sternum or calcifications, commonly encountered in patients undergoing PPVI, serve as reference points for the alignment. Previously placed devices, for example mechanical valves, occluders or stents, also aid in the marking process [21–23]. This technique of registration included stored fluoroscopy in two projections, manual alignment, preferably with several reference structures, on the two planes, and utilization of “auto fade” and “boost bone” tools to enhance precision of the alignment.
For angiographic registration two acquisitions were needed with a minimum 30° difference in angulation of the anterior-posterior plane (Figure 2 D). This can be achieved by right ventricle, aortic or pulmonary artery angiography, which is routinely performed prior to PPVI in the majority of patients. These angiographies can also be performed by utilizing manual (10 ml total) injections, an approach aimed at reducing the total quantity of dye exposure. Apart from the use of dye, the catheter in the aorta can, itself, be used to help register the overlay properly.
Finally, live guidance of the intervention is performed with the 3D roadmap or sole marking rings/points overlaid on the fluoroscopy in an AP plane (Figure 3). The roadmap follows C-arm (A plane) and table movement; however, care must be taken not to move the patients on the table as this would result in misalignment of the 3D reconstruction.

Statistical analysis

Data analysis was performed using GraphPad InStat software (GraphPad Software, Inc., San Diego, CA, USA). Data are presented as frequency with percentage of the total, median with range, or mean ± standard deviation, as appropriate. Student’s t-test or the Mann-Whitney test, where indicated, was used for analysis. The level of statistical significance was set at p ≤ 0.05.

Results

Patients and interventions

Fusion imaging with VesselNavigator was applied in 24 patients for planning (n = 4), suitability testing (n = 7) or live guidance during PPVI (n = 15) (Figure 4 A). In two patients VesselNavigator was used twice, during two separate sessions: for 3D guided RVOT balloon testing and PPVI respectively. The median age was 15.9 (4.9–64) years and median weight was 46 (16.5–116) kg. Twenty-one (87.5%) patients had previous surgery with implantation of a right ventricle-to-pulmonary artery conduit and the remaining 3 (12.5%) patients had a patch repair for correction of a tetralogy of Fallot.

Pre-catheterization imaging and segmentation

A 3D roadmap was created either from existing contrast MRI (n = 14) or CT (n = 8) data sets (Figure 4 B). The imaging studies were performed at a median interval of 92 days (0–58 months) before catheterization or treatment planning with VesselNavigator.
In the case of MRI data sets either a 3D whole heart sequence (n = 8), contrast enhanced angiography (n = 3) or a 2D cine sequence (n = 1) was utilized. In three patients suboptimal quality of the 3D datasets limited the desired segmentation. In two patients MRI scans were performed elsewhere and 3D data were too fragmented for importing to VesselNavigator. In 1 patient with only 2D cine sequences available, an acceptable quality roadmap was obtainable in the corresponding projections, whereas all others presented poor resolution.
Two CT scans were of suboptimal quality for segmentation of the target structures. In one patient the scan was focused on the RVOT, resulting in poor visualization of coronary arteries. In another patient, poor contrast opacification of the RVOT led to suboptimal visualization of the graft and pulmonary arteries. The median dose length product for the CT scan and the median contrast volume injected were 92.5 (39–469) mGy·cm and 40 (20–80) ml or 0.9 (0.5–1.9) ml/kg, respectively.

Registration

During all 22 catheterizations successful 2D–3D registration was performed (Figure 4 B). For fusion of the overlay, fluoroscopy images were acquired in 2 projections with test angiography (n = 16), calcifications (n = 8), spine/vertebrae (n = 8) or a previously placed artificial valve (n = 2) serving as reference points for orientation of the 3D roadmap against live fluoroscopy. Accurate initial overlay, confirmed with soft wire and catheter movement within the borders of the 3D roadmap, was achieved in 21 (95%) patients. In 1 patient suboptimal manual alignment of the roadmap and a low volume contrast injection required readjustment at the beginning of the procedure.

Live guidance

3D guidance was utilized during 22 catheterizations including RVOT balloon sizing (n = 7) or PPVI (n = 15). In the former group four patients were disqualified due to a large RVOT (n = 3) or coronary compression (n = 1). Two patients underwent PPVI in separate sessions and one awaits a custom made stent.
Six (27%) patients required intra-procedural readjustment of the 3D roadmap due to distortion of the anatomy after introduction of a stiff wire or sheath. One patient with bifurcation graft stenosis required repeat contrast injections due to significant distortion of the anatomy by large delivery sheath and balloon/stent assembly. The procedure, including graft and right pulmonary artery stenting with subsequent Melody valve implantation, was successfully finished with traditional 2D guidance. Prestenting was performed in all patients followed by implantation of a Melody (n = 10) or Sapien valve (n = 5) within the same session. Excluding one PPVI finished with 2D imaging, the remaining 21 (95%) interventions were successful with no complications related to 3D guidance.

CT vs. MRI 3D guidance

Comparison of demographic data showed no difference between patients guided with CT- or MRI-derived 3D roadmaps (Table II). Patients in the CT group received less absolute and weight indexed contrast volume, yet the differences were not statistically significant. The absolute and weight adjusted dose area product was lower in the MRI group, with the latter being statistically significant. There were no differences in absolute and weight adjusted fluoroscopy time between the two groups. The total study time was shorter in the CT group, but without statistical significance.

Discussion

Pre-catheterization imaging with either MRI or CT is mandatory in patient qualification for PPVI [24, 25]. Despite variances among centers regarding the optimal imaging method, the size of the RVOT and the location of coronary arteries must be evaluated. In addition to the commonly used multiplanar reconstructions, 3D reconstructions or even 3D printed models allow better understanding of the anatomy and simulation of the intended intervention [26, 27]. Recently, several centers introduced 3DRA for balloon testing as a means to exclude coronary artery compression and/or to guide stent implantation to the RVOT [15–18]. Despite the availability of these 3D modalities, in the majority of catheterization laboratories the traditional 2D imaging remains the gold standard for PPVI guidance.
There is a growing body of literature evaluating the use of fusion imaging with CT or MRI datasets for congenital and structural interventions [28–32]. Most of the protocols rely on 3D–3D registration, which requires two sets of 3D data including the pre-intervention scan and a rotational spin. The latter may be performed without contrast administration and with low radiation exposure to reduce the burden for the patient. However, a specific setup of the C-arm is mandatory and data processing is performed during the study, adding to its length.
We utilized a simple 2D–3D registration protocol, which requires stored fluoroscopy in two projections, similar to setting up an isocenter at the beginning of the study with traditional 2D guidance [23]. A recent study compared this protocol of integration of CT datasets with 2D angiography and 3DRA for guidance of PPVI [33]. Application of pre-catheterization imaging led to reductions in contrast and radiation exposure and study time as compared with 2D guidance, and contrast usage as compared with 3DRA.
In this study we successfully applied this direct 2D–3D registration protocol for incorporation of MRI and CT datasets. Where available we used bony structures, calcifications and previously placed devices as reference points. Although we have not yet objectively tested our theory, we feel that combination of all available reference structures improves the accuracy of the initial alignment. With such calibration it is possible to carry out the diagnostic phase of the procedure and, in select patients, even stent implantation to the RVOT, without angiography [34]. This is more likely with integration of the CT dataset. For fusion of the MRI dataset, angiography in two projections is necessary, as bony structures are not adequately visualized. This might be either routine pump injection or preferably low volume hand injection aimed only at delineating vessel borders. The latter approach allows reduction of the amount of dye, which may be further decreased when diluted contrast is used. Alternatively, some authors have reported utilization of airways for registration of MRI-derived 3D datasets [35, 36]. Typically, these protocols require specific MRI sequences to enhance visualization of the airways and are not routinely performed in current practice.
With the traditional 2D guidance the landmarks for stent implantation are typically set virtually with serial angiography. 3DRA may enhance positioning of the stent but comes with several disadvantages as previously mentioned. Application of fusion imaging allows highlighting of crucial structures or regions with marking rings or points. We commonly use marking rings for guidance of stent placement, as presented in Figures 2 and 5.
The offline pre-planning process costs additional time yet it brings overall benefits, as stent length, balloon diameter and potential pitfalls can be better assessed before starting the procedure. During the catheterization, continuous visualization of the stents’ landing zone marked with colored rings may limit or, according to the confidence of the operator, exclude the need for angiography during positioning of the stent. In our experience, segmentation and registration of MRI and CT datasets did not greatly differ and required similar time and effort. Similarly, live guidance with 3D roadmaps obtained from different types of pre-catheter imaging modalities provided the same level of confidence for the operators. The only significant difference, inherent to our protocol, was the need for contrast injection to fuse the MRI-derived 3D roadmaps. This may partially explain higher contrast utilization and longer study time in those guided with MRI. However, these differences were not statistically significant. With growing experience, we have adapted to using just a catheter position in the aorta or pulmonary artery for registration, which seems to prevent additional contrast exposure to the patients. This will be further analyzed in a recently established multicenter international registry of catheterizations guided with VesselNavigator.
The weight-adjusted dose area product was significantly lower in the MRI group. The majority of patients (9/14) in this group underwent catheterization with the AlluraClarity low X-ray dose system, in contrast to all patients in the CT group, who were treated with the older Xper angiographic system.
Due to the limited patient population we did not analyze subgroups of patients treated with different imaging platforms, different type of valves, or those with additional interventions. Further studies are warranted to explore the full benefits of the latest fusion imaging platform, especially with regard to the type of non-invasive imaging utilized.

Conclusions

With intuitive segmentation and direct 2D–3D fusion of MRI and CT datasets, VesselNavigator facilitates PPVI. Our initial data show that utilization of CT-derived roadmaps may lead to lower contrast exposure and a shorter procedural time, whereas application of MRI datasets may lead to lower radiation exposure. Further studies are warranted to explore the full benefits of the latest fusion imaging platform.

Acknowledgments

To Ms. Alexandra Hul (Science Circle for Congenital Heart Disease, Polish Mother’s Memorial Hospital) for editing the manuscript.

Conflict of interest

The German Heart Center Berlin holds a research contract for the use and assessment of the VesselNavigator image fusion software and acts as a reference center for Philips, The Netherlands.

References

1. Demkow M, Biernacka EK, Spiewak M, et al. Percutaneous pulmonary valve implantation preceded by routine prestenting with a bare metal stent. Catheter Cardiovasc Interv 2011; 77: 381-9.
2. Eicken A, Ewert P, Hager A, et al. Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients. Eur Heart J 2011; 32: 1260-5.
3. Biernacka EK, Rużyłło W, Demkow M, et al. Transcatheter pulmonary valve implantation in patients with right ventricular outflow tract dysfunction: early and mid-term results. J Invasive Cardiol 2015; 27: E82-9.
4. Fiszer R, Dryżek P, Szkutnik M, et al. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation. Cardiol J 2017; 24: 604-11.
5. Boshoff DE, Cools BL, Heying R, et al. Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label? Catheter Cardiovasc Interv 2013; 81: 987-95.
6. Haas NA, Moysich A, Neudorf U, et al. Percutaneous implantation of the Edwards SAPIEN(™) pulmonic valve: initial results in the first 22 patients. Clin Res Cardiol 2013; 102: 119-28.
7. Demkow M, Rużyłło W, Biernacka EK, et al. Percutaneous Edwards SAPIEN(™) valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch. Catheter Cardiovasc Interv 2014; 83: 474-81.
8. Promphan W, Prachasilchai P, Siripornpitak S, et al. Percutaneous pulmonary valve implantation with the Venus P-valve: clinical experience and early results. Cardiol Young 2016; 26: 698-710.
9. Jalal Z, Malekzadeh-Milani S, Hofbeck M, et al. A new percutaneous pulmonary valve implantation technique for complex right ventricular outflow tracts: the “folded melody valve”. Catheter Cardiovasc Interv 2015; 85: 604-10.
10. Tanase D, Grohmann J, Schubert S, et al. Cracking the ring of Edwards Perimount bioprosthesis with ultrahigh pressure balloons prior to transcatheter valve in valve implantation. Int J Cardiol 2014; 176: 1048-9. 
11. Morray BH, McElhinney DB, Cheatham JP, et al. Risk of coronary artery compression among patients referred for transcatheter pulmonary valve implantation: a multicenter experience. Circ Cardiovasc Interv 2013; 6: 535-42.
12. Fraisse A, Assaidi A, Mauri L, et al. Coronary artery compression during intention to treat right ventricle outflow with percutaneous pulmonary valve implantation: incidence, diagnosis, and outcome. Catheter Cardiovasc Interv 2014; 83: E260-8.
13. Goreczny S, Eicken A, Ewert P, et al. A new strategy to identify potentially dangerous coronary arterial patterns before percutaneous pulmonary valve implantation. Postep Kardiol Interw 2014; 10: 294-7.
14. Malone L, Fonseca B, Fagan T, et al. Preprocedural risk assessment prior to PPVI with CMR and cardiac CT. Pediatr Cardiol 2017; 38: 746-53.
15. Pockett CR, Moore JW, El-Said HG. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes. Neth Heart J 2017; 25: 82-90.
16. Peters M, Krings G, Koster M, et al. Effective radiation dosage of three-dimensional rotational angiography in children. Europace 2015; 17: 611-6.
17. Haddad L, Waller BR, Johnson J, et al. Radiation protocol for three-dimensional rotational angiography to limit procedural radiation exposure in the pediatric cardiac catheterization lab. Congenit Heart Dis 2016; 11: 637-46.
18. Nguyen HH, Balzer DT, Murphy JJ, et al. Radiation exposure by three-dimensional rotational angiography (3DRA) during trans­catheter melody pulmonary valve procedures (TMPV) in a pediatric cardiac catheterization laboratory. Pediatr Cardiol 2016; 37: 1429-35.
19. Stangenberg L, Shuja F, Carelsen B, et al. A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg 2015; 62: 448-55.
20. Goreczny S, Dryzek P, Moszura T. Use of pre-intervention imaging with a novel image fusion software for guidance of cardiac catheterisation in a patient with pulmonary atresia and major aortopulmonary collaterals. Cardiol Young 2016; 26: 1438-40.
21. Goreczny S, Dryzek P, Moszura T. Novel 3-dimensional image fusion software for live guidance of percutaneous pulmonary valve implantation. Circ Cardiovasc Interv 2016; 9: e003711.
22. Goreczny S, Dryzek P, Moszura T. Stent implantation to ductus arteriosus in a patient with interrupted aortic arch guided by CT image overlay. Cardiol Young 2017; 27: 1229-31.
23. Goreczny S, Dryzek P, Morgan GJ, et al. Novel three-dimensional image fusion software to facilitate guidance of complex cardiac catheterization. Pediatr Cardiol 2017; 38: 1133-42.
24. Biernacka EK, Rużyłło W, Demkow M. Percutaneous pulmonary valve implantation – state of the art and Polish experience. Adv Interv Cardiol 2017; 13: 3-9.
25. Ansari MM, Cardoso R, Garcia D, et al. Percutaneous pulmonary valve implantation: present status and evolving future. J Am Coll Cardiol 2015; 66: 2246-55.
26. Vukicevic M, Mosadegh B, Min JK, Little SH. Cardiac 3D printing and its future directions. JACC Cardiovasc Imaging 2017; 10: 171-84.
27. Valverde I. Three-dimensional printed cardiac models: applications in the field of medical education, cardiovascular surgery, and structural heart interventions. Rev Esp Cardiol 2017; 70: 282-91.
28. Glöckler M, Halbfaβ J, Koch A, et al. Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 2013; 82: 436-42.
29. Tacher V, Lin M, Desgranges P, et al. Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion. J Vasc Interv Radiol 2013; 24: 1698-706.
30. Kliger C, Jelnin V, Sharma S, et al. CT angiography-fluoroscopy fusion imaging for percutaneous transapical access. JACC cardiovasc Imaging 2014; 7: 169-77.
31. Goreczny S, Dryzek P, Moszura T, et al. 3D image fusion for live guidance of stent implantation in aortic coarctation – magnetic resonance imaging and computed tomography image overlay enhances interventional technique. Adv Interv Cardiol 2017; 13: 269-72.
32. Sandoval JP, Aristizabal G, Zabal-Cerdeira C. Aortic stent implantation using live 3-dimensional image fusion guidance. Rev Esp Cardiol 2018; 71: 750.
33. Goreczny S, Moszura T, Dryzek P, et al. Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: a comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 2017; 25: 91-9.
34. Goreczny S, Moszura T, Lukszewski M, et al. Three-dimensional image fusion of precatheter ct and mri facilitates stent implantation in congenital heart defects. Rev Esp Cardiol 2018; https://doi.org/10.1016/j.rec.2018.05.013.

35. Dori Y, Sarmiento M, Glatz AC, et al. X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization. Circ Cardiovasc Imaging 2011; 4: 415-24.
36. Fagan TE, Truong UT, Jone PN, et al. Multimodality 3-dimensional image integration for congenital cardiac catheterization. Methodist Debakey Cardiovasc J 2014; 10: 68-76.
Copyright: © 2018 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.