Image in intervention

Marking wire technique for zero-contrast percutaneous coronary interventions

Jerzy Sacha

Adv Interv Cardiol 2018; 14, 2 (52): 204–205
Online publish date: 2018/06/19
View full text Get citation
 
Zero-contrast percutaneous coronary intervention (PCI) is a new and promising approach in the prevention of contrast-induced nephropathy [1, 2]. It has been previously shown that by using this technique even PCI of the left main stem can be done [3]. However, one of its biggest challenges is the precise positioning of stents according to landing zones determined by intravascular ultrasound (IVUS). Performed in a case of right coronary artery stenosis (Figure 1 A), a new technique is presented which significantly facilitates stent implantation without contrast administration.
In order to establish both distal and proximal landing zones as well as to determine the stent length, two guidewires should be inserted through a double Y connector and a 7 Fr guiding catheter. The operating wire is inserted via the main port of the connector but the marking wire via its side port (Figure 1 B) – the marking wire is intended to guide the intervention. The distal landing zone is determined by IVUS and subsequently marked with the tip of the marking wire, i.e. by pulling back the wire to the level of the landing zone (Figure 1 C). Then, the position of the marking wire is secured by tightly screwing the connector’s side port and additionally a torquer is attached to prevent any displacement of the wire (Figure 1 B). Subsequently, the proximal landing zone and the stent length are determined by IVUS (Figure 1 D). Finally, the stent is located according to the position of the marking wire (Figure 1 E) and after removal of the wire it can be implanted. In the presented case, after balloon post-dilation and IVUS examination, one single injection of 5 ml of contrast was performed to document the PCI result and lack of complications (Figure 1 F).
This simple technique may significantly facilitate stent implantation and reduce the stent length, which is usually longer in PCI without contrast.

Conflict of interest

The author declares no conflict of interest.