eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2018
vol. 14
 
Share:
Share:
abstract:
Image in intervention

Melody valve implantation pre-procedural planning using custom-made 3D printed model of the region of interest

Robert Sabiniewicz
,
Jarosław Meyer-Szary
,
Piotr Potaż
,
Dariusz Jagielak
,
Tomasz Moszura

Adv Interv Cardiol 2018; 14, 2 (52): 210–211
Online publish date: 2018/06/19
View full text Get citation
 
Recent years have shown exponential growth in interest in 3D printing techniques in the field of medicine. One of the last specialties to adopt this novelty is cardiology, owing to the complexity of the cardiovascular system. Over the last year our team has gained a great deal of experience by adopting 3D printed heart models in daily clinical practice in all its fields – student education, patient counselling and pre-procedural planning and simulation [1]. We present an exemplary case of such 3D printed model application.
Melody valve implantation is considered one of the most complex procedures in structural interventions. We were challenged with a case of a 34-year-old man born with tetralogy of Fallot (TOF) palliated with B-T shunt at the age of 3 and 6 years, and treated with a homograft at the age of 8 years. Due to homograft stenosis, the patient underwent balloon angioplasty twice – at the ages of 18 and 33. In the most recent cardiac catheterization the right ventricular systolic pressure (RVSP) was 85 mm Hg with a trans-homograft pressure gradient of 64 mm Hg, and due to the recoil the balloon angioplasty did not provide a lasting effect; thus the patient was qualified for Melody valve implantation.
The complexity and the variability of homograft anatomy of post-TOF patients (Figure 1 A) makes every Melody valve implantation procedure a distinct challenge [2]. For that reason, we prepared a 3D model of the region of interest encompassing the right ventricular outflow tract (RVOT), homograft and pulmonary branches. The imaging modality was MRI 1.5T, contrast enhanced TWIST sequence on 1.9 mm slice thickness. For post-processing we used commonly available software including Osirix, Meshmixer, Meshlab and a printer dedicated Z-suite slicer to prepare the print. The model was printed with the fused deposition modelling (FDM) technique using Zortax desktop 3D printer available at our department. The image analysis and post-processing took 3 h, printing time was 7 h. Next the model was taken to the cath-lab for simulation (Figures 1 B–C) to better plan the procedure and shorten the total procedure time, fluoroscopy time and failure rate similarly to the experience of others [3].
The Melody valve implantation on a patient, preceded by double pre-stenting using 20 atm pressure, was carried out uneventfully on the next day (Figure 1 D). The procedure outcome was assessed to be excellent with good device position and stability, no stent...


View full text...