eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2017
vol. 13
 
Share:
Share:
abstract:
Original paper

Mesh-covered (Roadsaver) stent as a new treatment modality for symptomatic or high-risk carotid stenosis

Roman Machnik
,
Piotr Paluszek
,
Łukasz Tekieli
,
Karolina Dzierwa
,
Damian Maciejewski
,
Mariusz Trystuła
,
Andrzej Brzychczy
,
Krzysztof Banaszkiewicz
,
Robert Musiał
,
Piotr Pieniążek

Adv Interv Cardiol 2017; 13, 2 (48): 130–134
Online publish date: 2017/05/30
View full text Get citation
 
Introduction: Prevention of periprocedural stroke has a crucial role in carotid artery stenting (CAS) procedures.

Aim: To assess retrospectively 30-day safety and effectiveness of 41 procedures of internal and common carotid artery stenting using the Roadsaver double nitinol layer micromesh stent in 40 non-consecutive patients with symptomatic or high-risk carotid artery stenosis.

Material and methods: The patients were men (n = 31) and women (n = 9); mean age was 67.8 ±7.9 years. Femoral access was used in 39 cases, whereas radial access was used in 2. Proximal (n = 27) or distal (n = 14) embolic neuroprotection was used.

Results: The Roadsaver stents (nominal diameter 7, 8 or 9 mm, length 25 or 30 mm) were implanted successfully in all cases. One minor stroke occurred after common carotid artery intubation with a guiding catheter (before stent deployment) and one transient postprocedural ischemic attack (TIA) of the ipsilateral cerebral hemisphere was observed. Internal/common carotid artery stenosis severity was evaluated by duplex Doppler. Maximal peak systolic velocity (PSV) before CAS was in the range: 2.0–7.0 m/s, mean: 3.9 ±1.0 m/s, at 24–48 h after stenting mean PSV was 1.1 ±0.4 m/s (p < 0.05), and at 30 days 1.1 ±0.3 m/s (p < 0.05). Maximal end-diastolic velocity (EDV) was 0.85–3.5 m/s, mean 1.4 ±0.5 m/s, at 24–48 h after stenting mean EDV was 0.3 ±0.1 m/s (p < 0.05), and at 30 days 0.4 ±0.1 m/s (p < 0.05). No restenosis or thrombosis was observed. Angiographic stenosis decreased from 82.9 ±9.1% (range: 61–97%) to 19.3 ±7.3% (range: 0–34%) (p < 0.05).

Conclusions: The CAS using the Roadsaver stent seems to be safe and effective. Further studies involving larger patient populations and longer follow-up are needed.
keywords:

carotid artery stenting, Roadsaver stent, carotid artery disease, nitinol double-layer mesh stent