eISSN: 2299-0054
ISSN: 1895-4588
Videosurgery and Other Miniinvasive Techniques
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2016
vol. 11
 
Share:
Share:
abstract:
Original paper

Midline lumbar fusion using cortical bone trajectory screws. Preliminary report

Mateusz Bielecki
,
Przemysław Kunert
,
Marek Prokopienko
,
Arkadiusz Nowak
,
Tomasz Czernicki
,
Andrzej Marchel

Videosurgery Miniinv 2016; 11 (3): 156-163
Online publish date: 2016/09/12
View full text Get citation
 
PlumX metrics:
Introduction: Midline lumbar fusion (MIDLF) using cortical bone trajectory is an alternative method of transpedicular spinal fusion for degenerative disease. The new entry points’ location and screwdriving direction allow the approach-related morbidity to be reduced.

Aim: To present our preliminary experience with the MIDLF technique on the first 5 patients with lumbar degenerative disease and with follow-up of at least 6 months.

Material and methods: Retrospective analysis was performed on the first 5 patients with foraminal (4) or central (1) stenosis operated on between December 2014 and February 2015. Three patients were fused at L4–L5 and two at the L5–S1 level.

Results: No intra- or post-operative complications occurred with this approach. An improvement regarding the leading symptom in the early postoperative period (sciatica 4/4, claudication 1/1) was achieved in all patients. The mean improvements in the visual analogue scale for low back and leg pain were 2.2 and 4.8 respectively. The mean Oswestry Disability Index scores were 52% (range: 16–82%) before surgery and 33% (range: 12–56%) at 3-month follow-up (mean improvement 19%). At the most recent follow-up, 4 patients reported the maintenance of the satisfactory result. The early standing and follow-up X-rays showed satisfactory screw placement in all patients.

Conclusions: In our initial experience, the MIDLF technique seems to be an encouraging alternative to traditional transpedicular trajectory screws when short level lumbar fusion is needed. Nevertheless, longer observations on larger groups of patients are needed to reliably evaluate the safety of the method and the sustainability of the results.
keywords:

pedicle screw, midline lumbar fusion, cortical bone trajectory, minimally invasive spine surgery, lumbar degenerative disease

  