abstract:
Letter to the Editor

Neointima development in externally stented saphenous vein grafts. External stents are bad for the patient: why not use an undamaged saphenous vein for coronary artery bypass graft?

Michael R. Dashwood
,
Andrzej Loesch

Adv Interv Cardiol 2017; 13, 1 (47): 90–91
Online publish date: 2017/03/10
View full text Get citation
 
In their recent article, “Neotinima development in externally stented vein grafts”, Węglarz et al. assessed the effect of placing an external Dacron stent on lumen volume, neointima formation and the outer border of vein grafts using intravascular ultrasonography in coronary artery bypass graft (CABG) patients [1]. Over the period studied, the reduction in lumen volume was greater in stented versus normal grafts and, although there was no change in plaque volume in controls, stented grafts exhibited a significant increase in plaque size. Based on these results, they concluded, “saphenous vein grafts covered with an external elastic Dacron stent seem to be inferior to traditional ones”. It is not clear, from the methods, how the saphenous vein was harvested. The term “traditional” suggests that conventional harvesting was used, where the vein is stripped of its surrounding tissue. What other treatments were used? Were veins distended and what storage solution was used? It is surprising that the previous “Extent” study, by the Bristol group and published 10 years ago [2], was not cited in this article, since the approach used is virtually identical. In the Extent study two groups of patients undergoing CABG were randomized to have an Extent placed on a right or left coronary system target graft. The results were disappointing as, at follow-up angiography, all 17 Extent grafts were thrombosed, whereas all left internal thoracic artery and non-Extent vein grafts were patent. Given the detrimental effects of external Dacron stents, ethical considerations arise in continuing this form of treatment. Do the latest data from Węglarz et al. suggest this approach should be abandoned?
According to the details provided from the Bristol, Extent, trial “The stent was so designed... to prevent migration or kinking of the vein graft’’ and, in the Polish trial, “This extravascular stent is very resistant to bending”. Since the main aim of the external stent is to provide mechanical support and prevent the graft from kinking, had either group considered no-touch saphenous vein harvesting? Slower progression of atherosclerosis in no-touch compared with traditional saphenous vein grafts has been shown using angiography and intravascular ultrasound [3] with recent results showing that such grafts maintain a 16-year patency rate comparable to the internal thoracic artery [4]. When using this technique the saphenous vein is removed with minimal trauma and with its cushion...


View full text...