Introduction
Malignant hilar biliary obstruction (MHBO) is a disorder caused by primary or metastatic hepato-biliary tumours [1–5]. Approximately 70% of patients with MHBO are inoperable due to the advanced tumour stage [6]. Endoscopic or percutaneous biliary stenting has been widely used for patients with inoperable MHBO in order to relieve the symptoms of jaundice [7–10].
Asia-Pacific Working Group recommended that biliary stent should drain more than 50% of the entire liver [7]. Therefore, bilateral stenting is preferred among a majority of researchers [11–17]. There are two commonly used bilateral stenting techniques, which include side-by-side (SBS) and stent-in-stent (SIS) strategies. However, few comparative studies of the two techniques have been performed and they have yielded inconsistent findings [11–17], making the relative superiority of these techniques uncertain [10]. Therefore, a meta-analysis should be performed to detect the comparative results between SBS and SIS techniques.
Aim
This meta-analysis is conducted to investigate the efficacy and safety of SBS and SIS bilateral stenting for MHBO patients.
Material and methods
Study selection
This meta-analysis was performed as per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement [18]. This meta-analysis was registered at INPLASY.COM (No. INPLASY2021100031).
Relevant articles were searched in PubMed, Embase, Cochrane Library, Wanfang, VIP, and CINK using the following strategy: (((side-by-side OR (SBS)) AND ((stent-in-stent) OR (SIS))) AND (((hilar OR (biliary)) OR (Cholangiocarcinoma)). The timeline for the searches was from the establishment of the database to September 2021.
Inclusion criteria included:
type of study: comparative studies,
disease: MHBO,
types of interventions: SBS versus SIS bilateral metal stenting,
languages: all.
Exclusion criteria included:
Data extraction
Two researchers independently extracted the relative data from the included studies, and the bifurcation was solved by a third researcher. The baseline data of each study included first author’s name, publication year, country, types of design, cancer types, stenting approaches, Bismuth types, sample size, age, and gender. The outcomes of each study included technical success, functional success, complication rates, re-obstruction rates, stent patency, and overall survival (OS).
Quality assessment
Potential bias was examined with the Cochrane risk of bias tool for randomized controlled trials (RCTs). The items of Cochrane risk of bias tool include performance, attrition, detection, selection, reporting, and other sources of bias.
Non-RCTs were assessed by the 9-point Newcastle-Ottawa scale (NOS) [19], with studies exhibiting low, intermediate, or high levels of risk receiving scores of ≥ 7, 4–6, and < 4, respectively. The items of NOS include selection (4 points), comparability (2 points), and exposure (3 points).
Endpoints and definitions
Meta-analysis primary endpoints include stent re-obstruction rate and stent patency duration. The secondary endpoints include technical success rates, functional success rates, complication rates, and OS. SBS technique involves parallel stenting using two stents [10], and SIS technique involves placing a second SEMS contralaterally through the first stent mesh [10]. Successful bilateral stent deployment in an appropriate position with the ability of contrast to readily flow through the stent and into the duodenum was used to define technical success [17]. Functional success is defined as at least a 30% reduction in total bilirubin within 2 weeks postoperatively, or 50% within 4 weeks [20]. Stent patency duration is calculated from the stent insertion to stent re-obstruction or death. OS is calculated from the stent insertion to death.
Statistical analysis
RevMan v5.3 and Stata v12.0 were used for this meta-analysis. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) was calculated for dichotomous variables, and continuous variables were calculated by mean differences (MDs) with 95% CIs. Pooled stent patency duration and OS were calculated by hazard ratios (HRs) with 95% CI. Heterogeneity was determined by the I2 statistic and Q test. I2 > 50% was defined as high heterogeneity, and then the random effect model was used; otherwise, fixed effects models were used. Sources of heterogeneity were evaluated by sensitivity and subgroup analyses. Egger test was used to evaluate publication bias. P < 0.05 was the threshold for publication bias significance.
Results
Included studies
A total of 235 studies were initially identified from the databases. Finally, 7 studies fulfilled the inclusion criteria and entered into this meta-analysis (Figure 1). Among these 7 studies (Table I), 199 patients underwent SBS bilateral stenting and 180 patients underwent SIS bilateral stenting. Six studies were retrospective [11–13, 15–17] and one study was RCT [14]. Five studies used the endoscopic approach [11–15] and 2 studies used the percutaneous approach [16, 17]. Two studies included Bismuth I–IV patients [12, 15], 4 studies included Bismuth II–IV patients [11, 13, 16, 17], and one study included Bismuth III–IV patients [14]. The raw data of the treatment outcomes are shown in Table II.
Table I
Study/year/country | Study design | Cancer types | Stent approach | Bismuth types | Groups | Sample size | Age [years] | M/F | NOS |
---|---|---|---|---|---|---|---|---|---|
Ishigaki/2020/Japan [11] | Retrospective | C, G, P, MD | Endoscopic | II–IV | SBS | 24 | 74 | 13/11 | 8 |
SIS | 40 | 72 | 22/18 | ||||||
Kim/2012/Korea [12] | Retrospective | C, G, H, MD | Endoscopic | I–IV | SBS | 19 | 64.2 | 11/8 | 8 |
SIS | 22 | 65 | 17/5 | ||||||
Law/2013/USA [13] | Retrospective | C, other, MD | Endoscopic | II–IV | SBS | 17 | 68 for all | 19/5 for all | 7 |
SIS | 7 | ||||||||
Lee/2019/Korea [14] | RCT | C, G | Endoscopic | III/IV | SBS | 35 | 72.5 | 21/14 | – |
SIS | 34 | 74.5 | 15/19 | ||||||
Naitoh/2012/Japan [15] | Retrospective | C, G, other | Endoscopic | I–IV | SBS | 28 | 72 | 11/17 | 8 |
SIS | 24 | 75 | 14/10 | ||||||
Xu/2021/China [16] | Retrospective | C, G, H, other | Percutaneous | II–IV | SBS | 38 | 63 | 20/18 | 8 |
SIS | 26 | 65 | 11/15 | ||||||
Zhou/2020/China [17] | Retrospective | C, G, H, other | Percutaneous | II–IV | SBS | 38 | 63 | 19/19 | 8 |
SIS | 27 | 65.3 | 10/17 |
Table II
Study | Groups | TS (%) | FS (%) | TC (%) | EC (%) | RO (%) | AT (n) | Patency | OS |
---|---|---|---|---|---|---|---|---|---|
Ishigaki [11] | SBS | 95.8 | 100 | 60.9 | 47.8 | 47.8 | 17 | 205 d | 381 d |
SIS | 100 | 92.5 | 32.5 | 22.5 | 47.5 | 26 | 169 d | 238 d | |
Kim [12] | SBS | NG | 78.9 | 21.1 | 15.8 | 21.1 | NG | 118 d | 146 d |
SIS | NG | 94.1 | 13.6 | 9.1 | 18.2 | NG | 134 d | 225 d | |
Law [13] | SBS | 100 | NG | NG | NG | 52.9 | NG | NG | NG |
SIS | 100 | NG | NG | NG | 42.9 | NG | NG | NG | |
Lee [14] | SBS | 91.4 | 90.6 | 31.3 | 12.5 | 37.5 | 9 | 262 d | 221 d |
SIS | 100 | 94.1 | 23.5 | 11.8 | 44.1 | 9 | 253 d | 209 d | |
Naitoh [15] | SBS | 89.3 | 96.0 | 39.3 | 12.0 | 20.0 | 16 | 155 d | 198 d |
SIS | 100 | 100 | 8.3 | 4.2 | 41.7 | 15 | 104 d | 159 d | |
Xu [16] | SBS | 100 | 92.1 | 21.1 | NG | 18.4 | 20 | 149 d | 155 d |
SIS | 100 | 88.5 | 34.6 | NG | 38.5 | 13 | 75 d | 143 d | |
Zhou [17] | SBS | 100 | 92.1 | 21.1 | NG | 18.4 | 6 | 149 d | 155 d |
SIS | 100 | 88.9 | 33.3 | NG | 37.0 | 4 | 75 d | 143 d |
The included RCT has a high risk of performance bias and unclear risk of detection and other bias (Figure 2). The NOS for the retrospective NOS ranged from 7 to 8 (Table I).
Technical success
Six studies (SBS group: 180; SIS group: 158) reported the technical success rates [11, 13–17]. The pooled technical success rate was significantly higher in the SIS group than in the SBS group (100% vs. 96.1%, p = 0.04, Figure 3 A). The heterogeneity was not significant (I2 = 0%). There was no significant publication bias (Egger test, p = 0.98).
Functional success
Six studies (SBS group: 175; SIS group: 173) reported the functional success rates [11, 12, 14–17]. The pooled functional success rates were comparable between SBS and SIS groups (92% vs. 91.3%, p = 0.79, Figure 3 B). The heterogeneity was not significant (I2 = 0%). No significant publication bias was detected (Egger test, p = 0.50).
Total complication
Six studies (SBS group: 175; SIS group: 173) reported the total complication rates [11, 12, 14–17]. The pooled total complication rates were comparable between SBS and SIS groups (31.4% vs. 25.4%, p = 0.34, Figure 3 C). The heterogeneity was significant (I2 = 62%). The sensitivity analysis found that the significant heterogeneity disappeared (I2 = 49%) after removing Naitoh et al. [15] study. The pooled total complication rates were still comparable between SBS and SIS groups (p = 0.72). There was no significant publication bias (Egger test, p = 0.29).
Early complication
Four studies (SBS group: 99; SIS group: 120) reported the early complication rates [11, 12, 14, 15]. The pooled early complication rate was significantly lower in the SIS group than in the SBS group (13.3% vs. 21.2%, p = 0.04, Figure 3 D). The heterogeneity was not significant (I2 = 0%). There was no significant publication bias (Egger test, p = 0.45).
Re-obstruction
All studies (SBS group: 192; SIS group: 180) reported the stent re-obstruction rates. The pooled stent re-obstruction rate was significantly lower in the SBS group than in the SIS group (28.6% vs. 39.4%, p = 0.04, Figure 3 E). The heterogeneity was not significant (I2 = 0%). There was no significant publication bias (Egger test, p = 0.43).
Stent patency duration
The logHR for stent patency duration could be calculated from 6 studies [11, 12, 14–17]. The pooled logHR indicated that the stent patency duration was significantly prolonged in the SBS group relative to the SIS group (p = 0.01, Figure 3 F). The heterogeneity was significant (I2 = 83%). The sensitivity analysis did not find the source of heterogeneity. There was no significant publication bias (Egger test, p = 0.99).
OS
The logHR for OS could be calculated from 5 studies [11, 12, 14, 16, 17]. The pooled logHR indicated that the OS was comparable between the SBS and SIS groups (p = 0.27, Figure 3 G). The heterogeneity was significant (I2 = 72%). The sensitivity analysis did not find the source of heterogeneity. There was no significant publication bias (Egger test, p = 0.10).
Subgroup analyses
Table III shows the results of subgroup analyses based on different stenting approaches (endoscopic or percutaneous). When performing endoscopic stenting, SIS technique showed the superiorities in terms of technical success rate (p = 0.04), total complication rates (p = 0.007), and early complication rates (p = 0.04). However, when performing the percutaneous stenting, SBS technique showed the superiorities in terms of stent re-obstruction rate (p = 0.02) and stent patency duration (p = 0.0002).
Table III
Table IV shows the results of subgroup analyses based on different Bismuth types (Bismuth I–IV or II–IV). Based on the patients with Bismuth I–IV MHBO, SIS and SBS techniques showed the similar clinical efficacy. Based on the patients with Bismuth II–IV MHBO, SBS technique showed the superiorities in the terms of stent patency duration (p = 0.01) and OS (p = 0.03).
Table IV
Discussion
Metal stenting for patients with MHBO is always challenging because the optimal drainage method is not well known [1]. Many meta-analyses have been conducted to compare the clinical effectiveness between unilateral and bilateral stenting for MHBO [2–4, 20, 21]. Although some meta-analyses indicated that unilateral stenting may provide the equal functional success and long-term patency when compared to bilateral stenting [2, 20], drainage effectiveness was most closely associated with drainage of ≥ 50% of the total liver volume, especially for the patients with Bismuth III–IV MHBO [1]. Therefore, bilateral stenting to achieve drainage of ≥ 50% of the total liver volume may be required for favourable clinical efficacy in patients with MHBO [1].
However, the technical challenges associated with bilateral stenting may preclude its use [1]. Overall technical success rate of SIS and SBS techniques ranges from 73.3% to 100% [1]. Each method has its advantages and disadvantages, and deciding on the optimal technique is still difficult. Therefore, a meta-analysis regarding of SBS versus SIS stenting for MHBO is needed.
This meta-analysis provides a comprehensive evaluation of SBS and SIS bilateral stenting for patients with MHBO. First of all, SIS stenting seemed to provide a better technical success. However, the 2 included studies which used percutaneous stenting showed both 100% technical success rates for SBS and SIS stenting [16, 17]. A previous meta-analysis also showed that percutaneous SBS bilateral stenting and unilateral stenting were similar in technical success [21]. However, the endoscopic stenting revealed technical success rates to be significantly higher for the SIS group. It is not easy to place two stents simultaneously using the endoscopic approach. Although endoscopic biliary stenting is commonly used, percutaneous biliary stenting is of great value when endoscopic procedures are unsuccessful [22].
The functional success of SBS and SIS bilateral stenting was similar no matter what stenting approaches or Bismuth types were involved. These results might be explained since both SBS and SIS bilateral stenting can drain the bilateral intra-hepatic biliary tracts.
SIS bilateral stenting seemed to result in a lower early complication rate when compared to SBS bilateral stenting. Furthermore, when performing the endoscopic stenting, SIS technique may result in both lower total and early complication rates when compared to SBS technique. This phenomenon may be attributed to that the SBS deployment is distal biliary tract and stricture overexpansion by the two stents [10]. However, SBS and SIS techniques resulted in the similar complication rates in the subgroup of percutaneous stenting. When performing the percutaneous biliary stenting, a temporary drainage catheter is usually placed after stent insertion [23–26]. The post-stenting biliary drainage may decrease the early complication rate [8].
Stent re-obstruction and patency duration are the core endpoints of the studies regarding of the stent insertion [27–30]. In this meta-analysis, SBS bilateral stenting showed a significantly lower re-obstruction rate with longer stent patency duration when compared to SIS bilateral stenting. Two possible reasons for these findings can be considered. First, SBS technique provides two spaces for hilar drainage, in contrast to the SIS technique. Second, the hilar region stent mesh is greater in size in the SIS technique relative to the SBS technique, providing more opportunity for tumour ingrowth [15].
The stent patency duration was similar in SBS and SIS groups based on the patients with Bismuth types I–IV. These findings may be influenced by the Bismuth type I patients. Many researchers considered that Bismuth type I patients only require unilateral stenting [31]. In the subgroup of Bismuth types II–IV patients, longer stent duration was still found in the SBS group.
We observed similar OS duration in SBS and SIS groups. This is attributable to the finding that stenting alone has no effect on the tumour itself. Furthermore, the number of patients who received post-operative anticancer therapy was comparable in 2 groups in each included study. In some meta-analyses regarding unilateral and bilateral stenting for MHBO, the OS duration was also not influenced by the stenting techniques [20, 21, 31].
This meta-analysis has some limitations. First, a majority of the included studies are retrospective in nature. Furthermore, each study did not focus on a unique cancer type. These findings increased the risk of bias of this meta-analysis. Second, in these included studies, the anticancer treatments were performed based on the patients’ condition and interventional radiologists’ experience, these findings may further increase the risk of bias, especially for the endpoints of stent patency and OS. Third, a majority of the included studies are from Asia. Further more comprehensive, worldwide study may be possible when the use of stents becomes more widely used by other countries.
Conclusions
When comparing the SBS and SIS bilateral stenting for patients with MHBO, although SIS technique may have the superiorities of technical success and early complication rates, the longer stent patency was achieved by the SBS technique. To reduce the technical failure and complication rates when performing the SBS bilateral stenting, percutaneous stenting can be chosen.