eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2016
vol. 12
 
Share:
Share:
abstract:

Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device

Robert Sabiniewicz
,
Tomasz Królak
,
Lidia Woźniak
,
Szymon Budrejko
,
Grzegorz Raczak

Adv Interv Cardiol 2016; 12, 3 (45): 285–286
Online publish date: 2016/08/19
View full text Get citation
 
Percutaneous device closure is a well-established treatment of atrial septal defects (ASD) and the method of stroke prevention in a selected group of patients with patent foramen ovale (PFO). However, in case of drug-refractory atrial fibrillation (AF), when catheter ablation of pulmonary veins (PV) is required, the access to the left atrium is more difficult due to the ASD/PFO closure device.
We report a case of a 58-year-old man with PFO closure performed due to recurrent stroke (Nit-Occlud PFO device 30 mm in diameter). 3.8 years after the successful procedure the patient suffered from frequent, symptomatic episodes of drug-refractory AF. Before the pulmonary vein isolation (PVI) procedure a computed tomography scan was obtained to access the PV anatomy and to visualize the device position (Figure 1 A).
During PVI four venous accesses were obtained: two in the right and two in the left femoral veins. Diagnostic catheters were placed in coronary sinus and His bundle position. Left atrial access was obtained with a double transseptal puncture under both fluoroscopic and transesophageal echocardiography (TEE) guidance (Vivid q). Two 8.5-Fr transseptal sheaths were advanced over a guide wire to the superior vena cava. Then a transseptal needle was introduced into the sheath, and the whole unit was withdrawn under the fluoroscopic antero-posterior view and TEE guidance. The typical “jump” of the needle could not be observed due to device presence. The optimal site of the transseptal puncture was determined mostly on TEE guidance. In the bicaval view the correct position in the vertical axis was fixed. In the short axis view the position of the puncture needle was corrected in the anterior-posterior (A-P) axis (Figure 1 B). The transseptal system was positioned in relation to the interatrial septum, visualized by TEE and directed to the thinner part of the septum, below and posterior to the occluder device. When the transseptal unit was placed in the desired location, the position was confirmed by the typical tenting of the septum caused by the transseptal unit, and the needle was advanced through the septum. Effectiveness of the puncture was confirmed by saline injection to the left atrium and assessed by TEE (Figure 1 C). Finally, the transseptal sheath was advanced over the wire to the left atrium. A second transseptal puncture was performed using a similar technique, slightly inferior to the first access.
The ablation strategy consisted...


View full text...
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.