eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2020
vol. 16
 
Share:
Share:
abstract:
Image in intervention

Uncommon complication of common procedure. Embolization of multichambered radial artery pseudoaneurysm

Wojciech Stecko
1
,
Piotr Wańczura
1
,
Mateusz M. Wiśniowski
1
,
Andrzej Ochała
2

  1. Invasive Radiology Department, Hospital of the Ministry of the Interior and Administration, Rzeszow, Poland
  2. Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
Adv Interv Cardiol 2020; 16, 2 (60): 221–223
Online publish date: 2020/06/23
View full text Get citation
 
An 82-year-old woman with a history of hypertension, type 2 diabetes mellitus, myocardial infarction, ischaemic stroke and amputation of both lower extremities was admitted with the symptoms of evolving anterior wall myocardial infarction (STEMI). Coronary angiography performed with a right radial approach revealed critical stenosis in the mid-portion of the left descending coronary artery (LAD) and 75% lesion in the right coronary artery (RCA). The attempt of crossing the culprit lesion in the LAD was unsuccessful due to the calcified and tortuous anatomy of the vessel. In the next hours the chest pain subsided and ST segment elevation in ECG resolved. Two days later the second attempt of crossing the LAD lesion was made. The patient had been diagnosed with Leriche syndrome, so the procedure was performed by right brachial access – a right radial approach was rejected because of haematoma and a small tumour found at the site of previous puncture of that artery. Using the Fielder XT-R wire, microcatheter and rotational atherectomy, successful treatment of LAD/D1 with one drug-eluting stent (DES) implantation was done. The next day after the procedure Doppler ultrasonography of the forearm was carried out and revealed pseudoaneurysm of the radial artery. It was atypical and had unusual anatomy – it consisted of three connected cavities. The first one, 17.7 × 10.2 mm, was located exactly in the site of the artery puncture and was communicated by a narrow, 5 mm long “neck” with the artery and at the opposite side to the next chamber, 13.7 × 24.2 mm, located more proximately in the forearm. The third in the chain, 28 × 9 mm, beam-shaped chamber was connected to the second one and showed no flow. The two “last” chambers were partially occluded by the organizing clot. The peripheral blood flow in the radial artery was not disturbed and the vessel remained patent. Moderate haematoma of the forearm was present and it seemed to increase over the days. Apart from the tumour, a murmur in the area of artery puncture was heard. Because of favourable anatomy (tight “neck” between the cavity and artery) we injected in local anaesthesia 400 IU of thrombin into the first chamber of the pseudoaneurysm. This resulted in effective flow stop in the whole chain of cavities. The embolization procedure was monitored with Doppler technique and did not cause any ischaemic complications in the hand. Follow-up examinations repeated in the following days showed normal flow in all...


View full text...
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.