Introduction
Pancreatic neuroendocrine tumours (pNETs) are a distinct group of neoplasms arising from cells in the diffuse neuroendocrine system, located in the cells of Langerhans. Its incidence reaches 0.5 per 100,000 population [1]. This type of neoplasm might cause the presentation of overt clinical syndromes, based on the type of the hormone they secrete. Active peptides like insulin, gastrin, glucagon, somatostatin, and VIP produced by pNETs are responsible for the development of clinical symptoms, which is the case in functional tumours like insulinoma, gastrinoma, glucagonoma, somatostatinoma, and VIPoma [2]. Interestingly, most of these neoplasms (70%) do not produce distinct clinical syndromes, secreting minimal amounts of active peptides or no hormones at all [3, 4].
Because of the small size and indolent nature of pNETs, physicians and surgeons frequently face a huge clinical challenge during localization work-up either preoperatively or even intra-operatively [5]. Therefore, after biochemical confirmation of their presence, a variety of imaging techniques is nowadays utilized in order to successfully confirm their exact location within the pancreatic gland [6]. Computed tomography is the most commonly used modality, with a mean sensitivity for pNETs of 82%, while magnetic resonance imaging (MRI) has a similar mean sensitivity of 79%, being at the same time more sensitive for the detection of liver metastases [7, 8]. Finally, endoscopic ultrasound EUS and fine-needle aspiration is a useful extra imaging tool that is currently considered the most sensitive test for localizing small pNETs based on recent scientific data [9].
Recently, Indium-111 somatostatin receptor scintigraphy and gallium-68 positron emission tomography, both of which use radiolabelled somatostatin analogues to localize pNETs have brought a revolution in the localization process of pNETs, with the latter becoming the functional imaging modality of choice with sensitivity and specificity for the diagnosis to be 93% and 91%, respectively [10]. In spite of that, when these imaging modalities are used, pre-operative and intraoperative detection rates are successful in 92% of cases, whereas localization of tumours less than 2 cm remains difficult even during surgery [5, 11]. Intraoperative ultrasound seems to be beneficial in such cases, and recently fluorescence-guided (FG) surgery has emerged as a novel intraoperative modality to assist surgeons to localize such tumours, sentinel lymph nodes, and adjacent vital structures in real time [12]. The aim of this study is to investigate whether FG localization techniques with indocyanine green (ICG) can be utilized as a detection tool in cases of pNETs, especially when conventional imaging studies fail, along with any other clinical implications of this technique.
General principles of indocyanine green-fluorescence imaging
A growing body of scientific data have reported that near-infrared (NIR) fluorescence imaging is a promising technique able to facilitate intraoperative, real-time, visual information in many different surgical operations [13, 14]. Contrast agents that target tumour-specific characteristics are considered prerequisite in order to detect tumours using NIR fluorescence [15, 16]. Despite that, these novel tumour-specific agents are under development and are not clinically available yet. The only agent currently in use approved by the US Food and Drug Administration is ICG [17]. Although this is not tumour specific, the enhanced permeability and retention (EPR) effect of this agent can be used to obtain accumulation in tumours [18]. Newly formed, more porous blood vessels in cases of malignant tissue growth allow ICG to accumulate in the surrounding tissues. Concurrently, poorly developed lymphatics in the tumour area result in an increased retention of this agent [16].
Fluorescence imaging using ICG as a fluorophore has been applied in cases when it is necessary to assess coronary artery bypass graft patency, visualize cancerous lymph nodes, and identify sentinel lymph nodes during breast and gastric cancer surgeries [19]. Indocyanine green enters hepatocytes and is excreted into bile. Therefore, the technique was initially utilized in hepatobiliary surgery, able to visualize malignant liver lesions, bile ducts during cholecystectomy, and hepatic arterial/portal blood flow [20, 21]. Two separate studies have demonstrated the efficacy in visualization of pancreatic lesions, including 13% of pancreatic adenocarcinomas and 100% of pNETs [16, 22].
As far as the basic principles of ICG administration are concerned, ICG is usually administered intravenously before the beginning of the surgical procedure and in various time intervals intraoperatively. This dye becomes fluorescent when excited by light with specific wavelength in the near-infrared radiation (NIR) spectrum. A variety of fluorescence imaging systems exist, able to overlay fluorescence imaging on background colour images by visualizing visible and near-infrared rays [23, 24]. For open surgery the camera imaging head is usually manually positioned approximately 30 cm above the pancreas, and interpretation of the exact tumour location and the appropriate resection margins is feasible after intraoperative administration of ICG in non-toxic doses [19].
Usefulness of indocyanine green fluorescence imaging for real-time visualization of pancreatic neuroendocrine tumours
Scientific data have demonstrated that visualization of the liver perfusion status using ICG fluorescence imaging is feasible, highlighting the fact that liver regions without hepatic artery or portal vein flow do not demonstrate fluorescence [25, 26]. More specifically, Kawaguchi et al. [26] studied 21 consecutive patients who underwent liver resection with excision of major hepatic veins and were evaluated using ICG fluorescence imaging after clamping veins and injecting ICG. They concluded that ICG fluorescence imaging with hepatic vein clamping visualized non-veno-occlusive, veno- occlusive, and ischaemic regions, emphasizing the role of this technique in guiding liver transection by intraoperative navigation. The same team of authors hypothesized that hypervascular lesions such as pNETs can exhibit strong fluorescence images because their vascularity is richer than that of the surrounding parenchyma [19].
To evaluate and support their hypothesis Shirata et al. [19] tried to assess and compared the fluorescence intensity (FI) of pancreatic lesions and the surrounding parenchyma in a group of 23 patients based on the types and vascularity of pancreatic. A fluorescence imaging system (PINPOINT; Stryker, San Jose, CA) was used for open and laparoscopic surgery, while 1 ml of ICG (2.5 mg) was administered intravenously, placing a 30˚ near-infrared camera 30 cm above the surgical field. Five patients underwent distal pancreatic resection for neuroendocrine hypervascular tumours that ranged in size between 9.0 and 45.1 mm. They found that the FI values were significantly higher in pNETs compared with those in the surrounding pancreatic parenchyma, determining the exact location of resection line in order to obtain negative margins. Given the fact that the vascularity of pNETs is richer than that of the surrounding pancreatic parenchyma, pNETs exhibited 1.99 times higher FI than the surrounding tissues, making them identifiable in 100% of cases.
Paiella et al. [22] aimed to explore the results of the application of NIR in the laparoscopic resection of pNETs in a group of 10 patients with ages ranging from 39 to 66 years, who underwent laparoscopic pancreatic surgery (PS) for pNETs. The near-infrared system used in this study was the D-Light P (Karl Storz GmbH e Co. KG, Tuttlingen, Germany), and patients received ICG 25 mg given in 5 boluses of 5 mg each. Indocyanine green-fluorescence imaging identified all 10 pNETs. Nine laparoscopic distal pancreatectomies with splenectomy and 1 laparoscopic enucleation were performed. Eight non-functioning pNETs and 2 insulinomas were found in the final histological specimen. Ninety per cent of the lesions were detected after the second ICG bolus with a mean latency time of 80 sec, while the peak of tumour fluorescence was reached 20 min after the last bolus. In the case of enucleation, a fluorescent signal was identified at the bed of the initial resection, and therefore a further resection was performed in order to achieve negative margins. Thus, they concluded that NIR with ICG can play a role in laparoscopic pancreatic resection of pNETs. Table 1 summarizes the results of the aforementioned studies.
Table 1
Authors | Patients | Gender | Age | Histology | Fluorescence or defect | Indocyanine green – dose detection | Latency time (sec) |
---|---|---|---|---|---|---|---|
Shirata et al. [19] | 1 | F | 77 | NET | Fluorescence | N/R | N/R |
2 | M | 47 | NET | Fluorescence | N/R | N/R | |
3 | M | 70 | NET | Fluorescence | N/R | N/R | |
4 | M | 39 | NET | Fluorescence | N/R | N/R | |
5 | F | 34 | NET | Fluorescence | N/R | N/R | |
Paiella et al. [22] | 1 | M | 44 | NF-pNET | Fluorescence | 2 | 70 |
2 | M | 66 | NF-pNET | Fluorescence | 3 | 130 | |
3 | M | 59 | NF-pNET | Fluorescence | 2 | 75 | |
4 | F | 45 | Insulinoma | Fluorescence | 2 | 70 | |
5 | F | 43 | NF-pNET | Fluorescence | 2 | 70 | |
6 | M | 41 | Insulinoma | Fluorescence | 2 | 80 | |
7 | F | 39 | NF-pNET | Fluorescence | 2 | 80 | |
8 | F | 53 | NF-pNET | Fluorescence | 2 | 70 | |
9 | M | 43 | NF-pNET | Fluorescence | 2 | 75 | |
10 | F | 59 | NF-pNET | Fluorescence | 2 | 70 |
Discussion
Pancreatic neuroendocrine tumours are rare tumours with indolent growth and a propensity to metastasize. There is vast heterogeneity on how they appear; some of them present with debilitating hormonal syndromes and bulky liver metastatic burden, whereas others may be asymptomatic, incidentally discovered via imaging studies [6]. Surgery remains the cornerstone of treatment, and as far as patients with localized disease are concerned, resection may be curative. Even patients with large metastatic liver deposits seem to benefit, in terms of symptom control and survival, after debulking surgical operations [27].
Computed tomography and MRI have been employed with varying success rates depending on the tumour subtype. Although these imaging modalities have a very high rate of detection for larger tumours, the results for smaller tumours are not optimal [28]. Visual inspection, manual palpation, and intraoperative ultrasound are utilized nowadays in order to identify pancreatic lesions and their borders intraoperatively. Nonetheless, a significant proportion of pNETs are not identifiable with the conventional imaging techniques. Failure to localize pNETs occurs in up to 30% of patients with gastrinoma and 10% with insulinoma [5].
In this direction, ICG fluorescence imaging may facilitate the efforts of surgeons to identify occult pancreatic neuroendocrine lesions [19]. Invisible NIR fluorescent light, capable of penetrating millimetres into living tissue, is advantageous because it offers no change to the naked eye appearance of the surgical field, high-resolution images, and no significant increase in time of surgical operation. Newer imaging systems have been developed such as the FLARE™ system, which is also capable of displaying surgical anatomy with 2 independent channels of NIR fluorescence simultaneously [29].
This imaging modality might further help in the identification of resection margins and in cases of R1 resections, it could guide surgeons to operate further, as reported by Paiella et al. [22]. Newton et al. [17] concluded that NIR with ICG may provide meaningful tumour demarcation that correlates with tumour margins. Moreover, they reported that this technology may also be a promising way to assess the response to neoadjuvant treatment. Several studies also reviewed the use of NIR with ICG to assess its role within the sentinel node mapping; such studies are required in order to justify its use in these cases. Furthermore, the common bile duct and biliary anastomoses can easily be visualized during ICG-fluorescence study in cases of pancreatic resections [30]. Therefore, these imaging strategies could also be beneficial during PS in cases where the surgical anatomy is difficult to identify [16].
Yokoyama et al. [31] reported successful intraoperative detection of liver metastatic lesions (of at least 1.5 mm of diameter) in up to 16% of patients undergoing pancreatic resection without preoperative identifications of metastatic disease. Also, several preclinical studies have proven the efficacy of ICG fluorescence in the identification of pancreatic tumours in animal models [32, 33]. Based on the available scientific data, pNETs were visualized because they are hypervascular lesions when compared to the surrounding parenchyma [19, 22]. Thus, the correct timing of ICG administration seems to be intraoperative, because there are no influx and efflux transporters in the pancreatic tissues and lesions [34].
Conclusions
Indocyanine green fluorescence might play a pivotal role in PS for pNETs. However, further large-scale clinical studies are needed to assess the optimal dosage time of administration of ICG in order to maximize the positive results. The broad utilization of this technique, by increasing negative margin specimens and by leading surgeons to proceed to adequate lymphadenectomy during pancreatic resections, might affect long-term survival of these patients.