eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

3/2016
vol. 8
 
Share:
Share:
abstract:
Original paper

Highly conformal CT based surface mould brachytherapy for non-melanoma skin cancers of earlobe and nose

Łukasz Kuncman
,
Sławomir Kozłowski
,
Andrzej Pietraszek
,
Malwina Pietrzykowska-Kuncman
,
Justyna Danielska
,
Janusz Sobotkowski
,
Jolanta Łuniewska-Bury
,
Jacek Fijuth

J Contemp Brachytherapy 2016; 8, 3: 197–202
Online publish date: 2016/07/01
View full text Get citation
 
Purpose: Brachytherapy (BT), due to rapid dose fall off and minor set-up errors, should be superior to external beam radiotherapy (EBRT) for treatment of lesions in difficult locations like nose and earlobe. Evidences in this field are scarce. We describe computed tomography (CT) based surface mould BT for non-melanoma skin cancers (NMSC), and compare its conformity, dose coverage, and tissue sparing ability to EBRT.

Material and methods: We describe procedure of preparation of surface mould applicator and dosimetry parameters of BT plans, which were implemented in 10 individuals with NMSC of nose and earlobe. We evaluated dose coverage by minimal dose to 90% of planning target volume (PTV) (D90), volumes of PTV receiving 90-150% of prescribed dose (PD) (VPTV90-150), conformal index for 90 and 100% of PD (COIN90, COIN100), dose homogeneity index (DHI), dose nonuniformity ratio (DNR), exposure of organs. Prospectively, we created CT-based photons and electrons plans. We compared conformity (COIN90, COIN100), dose coverage of PTV (D90, VPTV90, VPTV100), volumes of body receiving 10-90% of PD (V10-V90) of EBRT and BT plans.

Results: We obtained mean BT-DHI = 0.76, BT-DNR = 0.23, EBRT-DHI = 1.26. We observed no significant differences in VPTV90 and D90 between BT and EBRT. Mean BT-VPTV100 (89.4%) was higher than EBRT-VPTV100 (71.2%). Both COIN90 (BT-COIN90 = 0.46 vs. EBRT-COIN90 = 0.21) and COIN100 (BT-COIN100 = 0.52 vs. EBRT-COIN100 = 0.26) were superior for BT plans. We observed more exposure of normal tissues for small doses in BT plans (V10, V20), for high doses in EBRT plans (V70, V90).

Conclusions: Computed tmography-based surface mould brachytherapy for superficial lesions on irregular surfaces is a highly conformal method with good homogeneity. Brachytherapy is superior to EBRT in those locations in terms of conformity and normal tissue sparing ability in high doses.
keywords:

brachytherapy, ear, mould, nose, skin cancer

 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.