eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

1/2015
vol. 7
 
Share:
Share:

Original paper
Influence of zonal dosimetry on prostate brachytherapy outcomes

Cheng William Hong
,
Chandana A. Reddy
,
Allan Wilkinson
,
Eric A. Klein
,
Jay P. Ciezki

J Contemp Brachytherapy 2015; 7, 1: 17-22
Online publish date: 2015/02/04
Article file
- Influence of zonal.pdf  [0.41 MB]
Get citation
 
 

Purpose

Prostate brachytherapy is commonly used for the definitive treatment of prostate cancer. Brachytherapy using permanent implantation of low-dose-rate (LDR) seeds alone for clinically localized prostate cancer can be achieved in a single outpatient visit. It allows for a higher dose of radiation to be given to the prostate while minimizing radiation exposure to the surrounding normal structures, and has similar efficacy to radical prostatectomy or external beam radiation therapy [1-3]. However, brachytherapy requires accurate placement of radioactive seeds and is more operator-dependent than external beam radiation therapy (EBRT), and implant quality can impact long-term outcome [4,5].
Quality assurance mandates a post-implant computed tomography (CT) scan to ensure proper implant positioning, and dosimetric parameters such as the D90 and V100 of the whole prostate (WP) are used to assess treatment adequacy [6]. The majority of prostate cancers, however, occur in the peripheral zone, and the WP dosimetric parameters do not account for the zonal anatomy of the prostate nor capture the heterogeneity in dose distribution within the prostate [7,8]. Herein, the influence of zone-specific dosimetry on rates of biochemical failure and toxicity is described.

Material and methods

Study design

This was an Institutional Review Board (IRB) approved retrospective review of 416 patients treated between 1996 and 2003 at our institution. All patients were treated according to the American Brachytherapy Society (ABS) guidelines for I-125 permanent prostate implantation (PI) (target dose of 144 Gy to the prostate), and no patient was excluded from therapy based on pre-operative urinary function or prostate volume. None of our patients were included in the RTOG 98-05 study.

Brachytherapy technique

Transrectal ultrasound (TRUS) images of the prostate were obtained at 0.5 cm intervals using the brachytherapy stepper (Amertek Medical Inc, Singer Island, FL, USA). Intra-operative physics planning was done with a 0.5 cm radial margin at the apex and base, ensuring that the urethra did not overlap with the 150% isodose line, and V100% of the rectum was less than 1 cm3 (VariSeed 8.0, Varian Medical Systems, Palo Alto, CA) [9]. Rapid strands were placed peripherally and loose seeds were placed centrally; needles were placed beginning with the position furthest from the ultrasound probe to minimize image distortion.

Evaluation of dosimetric quantifiers and clinical variables

The volumes of the whole prostate were already contoured on post-implant CT scans as part of the standard quality assurance process and calculation of D90 and V100 for clinical purposes. As the contours by treating physicians were used as a reference for contouring the transitional zone (TZ) and peripheral zone (PZ), the WP was not re-contoured for this study. The TZ was contoured as an area of similar shape to the WP but extending to approximately half of the anterio-posterior diameter of the prostate on axial CT slices (Fig. 1). The PZ was defined to be the remainder of the previously contoured prostate that was not included in the TZ. This method was chosen in order to yield zonal volumes that are consistent with known relative sizes of each zone of the prostate [10,11]. Urethral dose was not quantified as imaging was performed without catheter placement. Post-implant dosimetric analysis was performed according to ABS guidelines, and D90, D100, V100, V150, V200, V300, and V400 were calculated for the WP, TZ, and PZ. Pairwise t-tests comparing V100 (as a percentage of the zone volume) and D90 (in Gy) between zones of the prostate were done.
Clinical and treatment characteristics were examined as well, including the duration of androgen deprivation therapy (ADT), race, clinical stage, initial prostate-specific antigen (PSA), Gleason score, National Comprehensive Cancer Network risk stratification, and post PI PSA measurements (Table 1). Biochemical failure was defined using the Phoenix criteria (increase in 2.0 ng/ml over nadir PSA) [12]. Five-year and 10-year rates for biochemical recurrence-free survival, distant metastasis-free survival, and prostate cancer-specific mortality were computed. Only patients with three or more PSA measurements were included in the analysis of biochemical recurrence-free survival, as two PSA measurements are required for the definition of biochemical recurrence, and a third is needed to rule out
PSA bounce. Toxicity data was collected during clinical follow-up visits, and analyzed retrospectively. Toxicity was scored according to Common Terminology Criteria for Adverse Events (CTCAE) version 4.0 criteria, and descriptive statistics for late genitourinary (GU) and gastrointestinal (GI) toxicity was tabulated [13]. Five-year and 10-year rates for grade 3 or higher late GU and GI toxicity were computed using Kaplan-Meier analysis.

Statistical analysis

Statistical analysis was performed using SAS 9.2 and JMP 9.0 software (SAS Institute, Cary, NC, USA). Cox proportional hazards regression was used to assess clinical and dosimetric parameters as predictors for biochemical failure and late toxicity. Variables found to be significant on univariate analysis and were included in multivariable analysis. All t-tests were performed as two-tailed analyses, and a significance level of 0.05 was used for all statistical testing.

Results

Population characteristics

The median age and initial PSA was 68 years (range: 45-87 years) and 6.1 ng/ml (range: 0.4-33.9 ng/ml), respectively. The median follow-up time for the study population was 8.8 years (range: 0.2-15.1 years) with a median number of 9 post PI PSA measurements (range: 0-41). The characteristics of the study population are as described in Table 1, and dosimetric measurements and implant characteristics are described in Table 2. Dosimetric parameters are compared between the WP, TZ, and PZ (Table 5). As intended by peripheral loading of sources, the TZ received lower doses of radiation than the WP (p < 0.0001), which in turn received lower doses than the PZ (p < 0.0001).

Biochemical failure

The 5-year and 10-year rates for biochemical recurrence-free survival were 92.4% (95% CI: 89.6-95.3%) and 82.4% (95% CI: 77.2-87.7%) (Fig. 2). The 5-year and 10-year rates for distant metastasis-free survival were 97.8% (95% CI: 96.2-99.4%) and 92.4% (95% CI: 88.4-96.5%). The 5-year and 10-year rates for prostate cancer-specific mortality were 0.58% (95% CI: 0-1.37%) and 0.97% (95% CI: 0-2.08%).
On univariate Cox proportional hazards regression analysis, initial PSA, Gleason 7+ disease, duration of ADT, WP V100, TZ V100, TZ D90, PZ V100, length and width of the prostate, and PSA frequency were significant predictors for the presence/absence of biochemical failure (Table 4). As PSA frequency is associated with biochemical failure, it was included in the multivariable analysis so that its effect can be adjusted for. On multivariable analysis of these variables, only initial PSA, Gleason 7+ disease, and PSA frequency remained significant (Table 5).

Toxicity

Thirty-six patients (8.7%) developed late grade 3 or higher GU toxicity, whereas 7 patients (1.7%) developed late grade 3 or higher GI toxicity (Table 6). The 5-year and 10-year rates of grade 3 or higher GU toxicity was 6.1% (95% CI: 3.7-8.6%) and 10.9% (95% CI: 7.0-14.7%). The 5-year and 10-year rates of grade 3 or higher GI toxicity was 1.8% (0.5-3.2%) and 1.8% (0.5-3.2%). Genitourinary toxicity was classified as obstructive or irritative, and the grade 3 or greater GU toxicity was predominately because of the need to relieve urinary obstruction (94.4%). On univariate Cox proportional hazards regression, only V200 and V300 in the TZ was significantly associated with grade 3 or higher late GU toxicity (Table 7). Age, race, duration of ADT, activity, prostate volume, length, width, height, TZ D90, TZ V100, TZ V150, TZ V400, TZVolume, BMI, and history of diabetes were not. Due to the low event rate, Cox proportional hazards regression to identify factors predictive of late grade 3 or higher GI toxicity was not performed.

Discussion

Although there are established guidelines for PI target dosage, this study demonstrates that radiation dose delivered to the prostate is not uniform. At our institution, the peripheral distribution of sources is intended to reduce radiation dose delivered to the urethra within the constraints of whole prostate dosimetry guidelines.
Based on target dosimetric parameters for the whole prostate, the TZ appears to be underdosed. Yet, on multivariable analysis, neither WP nor zone-specific dosimetry was significantly associated with biochemical failure, suggesting that overall, lower TZ dose is not necessarily associated with worse outcomes. In the absence of significant benign prostate hypertrophy, the PZ constitutes the majority of prostate [14]. The majority of prostate cancers arise from the PZ, which tends to receive a higher treatment dose, using the technique described here, than WP dosimetry would suggest. In this analysis, the 10-year rates of late grade 3 or higher GU and GI toxicity was 10.9% and 1.8%. In addition, the TZ volume, which receives particularly high doses, as characterized by V200 and V300, may be associated with increased late GU toxicity, a finding which has been consistently observed in HDR brachytherapy studies having less follow-up than this series [15-17]. This is likely due to islands of high dose that are in close proximity to the urethra. High-dose-rate brachytherapy has the technical advantage of control over post-implant dosimetry, although it is much more invasive than LDR brachytherapy [18]. While there is some evidence to suggest that prostate length is associated with late GU toxicity likely due to greater medial lobe size and correspondingly higher doses to the bladder neck, presumably due to backscatter from the medial lobe to the bladder neck, our data did not demonstrate such a relationship [19-21].
The rates of long-term biochemical failure and late toxicities following the use of brachytherapy for prostate cancer with or without EBRT have been investigated in RTOG 00-19 and RTOG 98-05 [22,23]. In RTOG 00-19, which combined brachytherapy with EBRT, there was a 15% rate of grade 3 or higher GU/GI toxicities after four years, even though the target dose of PI was lowered to 108 Gy to account for the addition of EBRT [22]. In contrast, the rate of late (beyond 9 months) grade 3 toxicities was 3.2% in RTOG 98-05 using the same protocol management as RTOG 00-19 [23]. The high degree of variation in toxicity may be due to the oversimplification of treating the whole prostate as a single homogenous organ. It is also possible that the grading of toxicity can be highly subjective and that patient selection may play a role. In our series, a simple urethral dilation was graded as a grade 3 GU toxicity as was a TURP or similar procedure, in which prostate tissue was removed to relieve obstruction. We also had no pre-treatment selection bias relative to urinary function while RTOG 98-05 required all patients to have an AUA voiding score of < 18. Even if V100 and D90 are similar for two patients, there can be substantial differences in dose distributions, suggesting that standard dosimetric parameters may not be fully representative of the implant quality and dose distribution [24]. It is interesting to note that shorter width and length were significant predictors of biochemical failure on univariate analysis, as the TZ is closer to the PZ, and these glands would be more difficult to implant.
Given the learning curve of prostate brachytherapy, in RTOG 00-19 it would not be unusual that centers with less accrual would deliver higher treatment doses based on dosimetric quantifiers than centers with more experience, as a higher treatment dose is not necessarily a superior treatment [25,26]. An even distribution of seeds results in uneven dose distributions, with the central region receiving a higher dose, and an overtreatment of the urethra, as well as surrounding organs may also contribute to higher than expected genitourinary toxicity [27]. In contrast to EBRT, which delivers a relatively homogenous treatment dose to the tissues within the beam, the advantage of brachytherapy is the ability to deliver a higher dose to the prostate as a whole, while being able to manipulate the dose distribution within the prostate to account for zonal anatomy by judicious placement of sources. As such, attention to dose painting is critical for tumor control and limiting toxicities. This is especially important for patients at higher risk of significant toxicity, such as those with a history of TURP [28].
Limitations of this study include its retrospective nature, as well as the reflection of outcomes at a single tertiary-care referral center. As prostate zonal anatomy is not clearly visualized on CT, there may be significant variability in contouring, although a standardized method was used in order to minimize this effect [29].

Conclusions

In conclusion, dose distribution within the prostate can be heterogeneous and standard whole prostate dosimetric parameters based on a prescription dose may not be fully representative of implant quality [30]. Acceptable clinical outcomes can be obtained even when the TZ systematically receives a lower radiation dose than the rest of the prostate to spare the urethra. Increased awareness of zonal anatomy of the prostate during treatment planning may reduce late toxicities without sacrificing efficacy.

Acknowledgements

The work has been presented as a poster at the 56th ASTRO 2014 Annual Meeting.

Disclosure

Authors report no conflict of interest.

References

1. Ciezki JP, Klein EA, Angermeier K et al. A retrospective comparison of androgen deprivation (AD) vs. no AD among low-risk and intermediate-risk prostate cancer patients treated with brachytherapy, external beam radiotherapy, or radical prostatectomy. Int J Radiat Oncol Biol Phys 2004; 60: 1347-1350.
2. Shapiro EY, Rais-Bahrami S, Morgenstern C et al. Long-term outcomes in younger men following permanent prostate brachytherapy. J Urol 2009; 181: 1665-1671; discussion 1671.
3. Vicini FA, Martinez A, Hanks G et al. An interinstitutional and interspecialty comparison of treatment outcome data for patients with prostate carcinoma based on predefined prognostic categories and minimum follow-up. Cancer 2002; 95: 2126-2135.
4. Zelefsky MJ, Kuban DA, Levy LB et al. Multi-institutional analysis of long-term outcome for stages T1-T2 prostate cancer treated with permanent seed implantation. Int J Radiat Oncol Biol Phys 2007; 67: 327-333.
5. Potters L, Morgenstern C, Calugaru E et al. 12-year outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer. J Urol 2008; 179: S20-24.
6. Nag S, Beyer D, Friedland J et al. American Brachytherapy Society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer. Int J Radiat Oncol Biol Phys 1999; 44: 789-799.
7. Nasser NJ, Wang Y, Borg J et al. Sector analysis of dosimetry of prostate cancer patients treated with low-dose-rate brachytherapy. Brachytherapy 2014; 13: 369-374.
8. Spadinger I, Morris WJ, Keyes M et al. Quadrant dosimetry as a predictor of biochemical relapse in 125I prostate brachytherapy. Brachytherapy 2011; 10: 87-97.
9. Wilkinson DA, Lee EJ, Ciezki JP et al. Dosimetric comparison of pre-planned and or-planned prostate seed brachytherapy. Int J Radiat Oncol Biol Phys 2000; 48: 1241-1244.
10. McNeal JE. The zonal anatomy of the prostate. Prostate 1981; 2: 35-49.
11. McLaughlin PW, Troyer S, Berri S et al. Functional anatomy of the prostate: implications for treatment planning. Int J Radiat Oncol Biol Phys 2005; 63: 479-491.
12. Roach M 3rd, Hanks G, Thames H Jr et al. Defining biochemical failure following radiotherapy with or without hormonal therapy in men with clinically localized prostate cancer: recommendations of the RTOG-ASTRO Phoenix Consensus Conference. Int J Radiat Oncol Biol Phys 2006; 65: 965-974.
13. National Institutes of Health, National Cancer Institute. Common Terminology Criteria for Adverse Events (CTCAE) Version 4.0 [Internet], 2010 [cited 2014 May 30]. Available from: http://evs.nci.nih.gov/ftp1/CTCAE/About.html
14. McNeal JE, Redwine EA, Freiha FS et al. Zonal distribution of prostatic adenocarcinoma. Correlation with histologic pattern and direction of spread. Am J Surg Pathol 1988; 12: 897-906.
15. Akimoto T, Katoh H, Noda S et al. Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity. Int J Radiat Oncol Biol Phys 2005; 63: 472-478.
16. Ghadjar P, Keller T, Rentsch CA et al. Toxicity and early treatment outcomes in low- and intermediate-risk prostate cancer managed by high-dose-rate brachytherapy as a monotherapy. Brachytherapy 2009; 8: 45-51.
17. Ghadjar P, Matzinger O, Isaak B et al. Association of urethral toxicity with dose exposure in combined high-dose-rate brachytherapy and intensity-modulated radiation therapy in intermediate- and high-risk prostate cancer. Radiother Oncol 2009; 91: 237-242.
18. Skowronek J. Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options. J Contemp Brachytherapy 2013; 5: 33-41.
19. Elshaikh MA, Angermeier K, Ulchaker JC et al. Effect of anatomic, procedural, and dosimetric variables on urinary retention after permanent iodine-125 prostate brachytherapy. Urology 2003; 61: 152-155.
20. Pinkawa M, Fischedick K, Treusacher P et al. Dose-volume impact in high-dose-rate Iridium-192 brachytherapy as a boost to external beam radiotherapy for localized prostate cancer – a phase II study. Radiother Oncol 2006; 78: 41-46.
21. Pal RP, Bhatt JR, Khan MA et al. Prostatic length predicts functional outcomes after iodine-125 prostate brachytherapy. Brachytherapy 2011; 10: 107-116.
22. Lee WR, Bae K, Lawton C et al. Late toxicity and biochemical recurrence after external-beam radiotherapy combined with permanent-source prostate brachytherapy: analysis of Radiation Therapy Oncology Group study 0019. Cancer 2007; 109: 1506-1512.
23. Lawton CA, Hunt D, Lee WR et al. Long-term results of a phase II trial of ultrasound-guided radioactive implantation of the prostate for definitive management of localized adenocarcinoma of the prostate (RTOG 98-05). Int J Radiat Oncol Biol Phys 2011; 81: 1-7.
24. D’Souza WD, Thames HD, Kuban DA. Dose-volume conundrum for response of prostate cancer to brachytherapy: summary dosimetric measures and their relationship to tumor control probability. Int J Radiat Oncol Biol Phys 2004; 58: 1540-1548.
25. Lee WR, deGuzman AF, Bare RL et al. Postimplant analysis of transperineal interstitial permanent prostate brachytherapy: evidence for a learning curve in the first year at a single institution. Int J Radiat Oncol Biol Phys 2000; 46: 83-88.
26. Lee WR, Bae K, Lawton CA et al. A descriptive analysis of postimplant dosimetric parameters from Radiation Therapy Oncology Group P0019. Brachytherapy 2006; 5: 239-243.
27. Wallner K, Roy J, Harrison L. Tumor control and morbidity following transperineal iodine 125 implantation for stage T1/T2 prostatic carcinoma. J Clin Oncol 1996; 14: 449-453.
28. Salembier C, Rijnders A, Henry A et al. Prospective multicenter dosimetry study of low-dose Iodine-125 prostate brachytherapy performed after transurethral resection. J Contemp Brachytherapy 2013; 5: 63-69.
29. Lee WR, Roach M 3rd, Michalski J et al. Interobserver variability leads to significant differences in quantifiers of prostate implant adequacy. Int J Radiat Oncol Biol Phys 2002; 54: 457-461.
30. Aronowitz JN, Rivard MJ. The phylogeny of permanent prostate brachytherapy. J Contemp Brachytherapy 2013; 5: 89-92.
Copyright: © 2015 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.