Ta strona używa pliki cookies, w celu polepszenia użyteczności i funkcjonalności oraz w celach statystycznych. Dowiedz się więcej w Polityce prywatności.
Korzystając ze strony wyrażasz zgodę na używanie plików cookies, zgodnie z aktualnymi ustawieniami przeglądarki.
Akceptuję wykorzystanie plików cookies
eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

1/2025
vol. 17
 
Share:
Share:
abstract:
Original paper

Skin marker for MR-only surface high-dose-rate brachytherapy

Evangelia Kaza
1
,
Phillip M. Devlin
1
,
Desmond O’Farrell
1
,
Ivan Buzurovic
1

  1. Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA
J Contemp Brachytherapy 2025; 17, 1: 43–53
Online publish date: 2025/02/27
View full text Get citation
 
Purpose:
Recent advances in surface high-dose-rate (HDR) brachytherapy imaging indicate that flap applicators, human skin, and fibromatosis can be visualized using MRI. Complete MR-only surface brachytherapy workflows would require skin marker identification to define clinical target edges. However, CT markers are not detected on MR images, and common MR markers are unsuitable for continuous surface target tracing. In this paper, we proposed an alternative skin marker that was evaluated for MRI and CT detectability and contourability using a brachytherapy treatment planning system (TPS).

Material and methods:
Commercially obtained silicone rubber tubes of 2 or 3 mm diameter were taped on the hand of an anthropomorphic phantom, a healthy volunteer, and three palmar fascial fibromatosis patients. Subjects were imaged with an optimized 3D pointwise encoding time reduction with radial acquisition (PETRA) sequence, and a volumetric interpolated breath-hold examination (VIBE) sequence with Dixon reconstruction. Additionally, patients underwent standard CT imaging. Obtained images were reviewed for tube conspicuity, and tubes were tracked on axial views using Oncentra Brachy TPS. Independent tube and muscle reference contours were drawn in MIM for quantitative analysis, considering the three orthogonal imaging planes.

Results and Conclusions:
Silicone rubber tubes were detected with positive signal on PETRA, VIBE, and CT images. Among the MR series, Dixon VIBE fat-only showed the highest contrast against muscle tissue and the best separation from human skin, followed by DIXON opposed-phase. 3 mm diameter tubes were tracked better by TPS than 2 mm diameter ones. Considering MR images in the three orthogonal planes in MIM was more helpful for localizing the entire tube than using axial images only in TPS. All obtained contour shapes generally agreed with the known tube positions. Overall, solid silicone rubber tubes of 3 mm diameter represent a suitable skin marker alternative to CT markers for MR-only surface HDR brachytherapy.

keywords:

MRI, skin HDR brachytherapy, surface markers

 
Quick links
© 2025 Termedia Sp. z o.o.
Developed by Bentus.