Purpose
Low-dose-rate brachytherapy (LDR-BT) is an effective curative treatment for low- and intermediate-risk localized prostate cancer (PCa) [1], and as salvage radiotherapy with curative intent in localized recurrence [2]. However, the risk of rectal toxicities poses a major challenge to prostate irradiation. This was demonstrated in a large retrospective study, which reported an incidence of 20.57% grade 1 proctitis and 6.4% grade 2 proctitis, following individual or combination BT [3]. Significantly, von Gellekom et al. demonstrated a correlation between increasing rectal D2cc with an increasing incidence of rectal toxicity [4]. Snyder et al. also reported a reduced rate of ≥ grade 2 rectal toxicity, if V100 to the rectum was minimized to < 1.3 cc [5]. Peters et al. further recommended minimizing D2cc to less than 100 Gy in whole gland salvage iodine-125 (125I) BT prostate permanent implant to minimize severe gastrointestinal (GI) toxicities [6]. Furthermore, Veccia et al. demonstrated that reducing post-LDR-BT implant rectal V100 (RV100) to ≤ 0.5 cc, yielded improved acute and chronic rectal function and patient’s quality of life [7]. All current literature demonstrated a need to minimize both rectal dose and rectal volume receiving maximum irradiation in order to avoid severe GI complications.
The use of a bio-degradable recto-prostatic spacer has been widely studied over the past decade and examining its’ utility to increase the distance between prostate and rectum and thus, minimizing radiation dose received by the rectum. Currently available options for recto-prostatic spacer include hyaluronic acid (HA), implanted balloons [8], collagen implants [9], and polyethylene glycol hydrogel (HS). Hyaluronic acid, HS, and bio-degradable implanted balloons all demonstrated promising preliminary results in reducing rectal dosimetry [10-13] and decreasing rates of acute and chronic rectal toxicities [14, 15].
Both HS and HA rectal spacers present as cost-effective [16], safe, and effective recto-prostatic spacers. Current evidence suggests a significant reduction in radiation dose to the rectum in HS patients undergoing LDR-BT with or without external beam radiotherapy (EBRT), when compared to patients without hydrogel injection [17-20]. Furthermore, HS is associated with minimal post-operative complications and low rates of grade ≥ 3 acute or late rectal toxicities [13, 21-25]. Despite the promising findings from the literature, there have been a lack of large scale prospective clinical trials conducted for HS or HA rectal spacers in LDR-BT. As a result, this retrospective multi-institutional cohort study aims to report the rectal dosimetry and toxicity outcomes in men with PCa treated with LDR-BT with or without HS or HA rectal spacer (RS) insertion.
Material and methods
Study design, setting, and ethics
This retrospective case-control cohort study, assessing a prospective database, was performed to evaluate the efficacy and safety of HS or HA RS in LDR-BT for patients with clinically localized low-risk and intermediate-risk PCa at a private radiation oncology center (Genesis Care) in Melbourne, Australia. Ethics approval was sourced from the above institution on March 5, 2018. Between October 2017 and July 2019, 70 consecutive patients were enrolled into this study. LDR-BT prescription was 145 Gy modified peripherally loading (MPD) using 125I as monotherapy or with downsizing androgen deprivation therapy (ADT). The use of HS or HA RS was based on the preference of treating physician (i.e., urologist) only. HS RS (SpaceOAR®, Boston Scientific, MA, USA) was exclusively used for insertion prior to 2020, whilst HA RS (Barrigel®, Palette Life Sciences, Stockholm Sweden) was preferred following 2020, as it became commercially available in Australia.
All patients were initially assessed with a thorough medical history, examination, and serum prostate specific antigen (PSA) level. A digital rectal examination (DRE) was performed to evaluate patient’s clinical T-stage (cT). Transperineal ultrasound-guided biopsy (TPUS) was performed and assessed by an accredited general pathologist to produce pathological staging with either Gleason score or International Society of Urological Pathology (ISUP) score. All patients with Gleason score > 7 was staged with computerized tomography (CT) scan of abdomen and pelvis, magnetic resonance imaging (MRI) prostate, and/or whole-body bone scan (WBBS).
Prostate cancer stratification was calculated based on D’Amico classification [26]. Low-risk PCa was defined as Gleason score ≤ 6, PSA ≤ 10 ng/ml, and stage cT1-cT2a; favorable and unfavorable intermediate-risk PCa were defined as Gleason score of 7 (favorable intermediate-risk group was defined as Gleason 3+4 grade group 2, whilst unfavorable risk group was defined as Gleason 4+3 grade group 3), and/or stage cT2b PCa. Patients without a specified cT2 sub-stage but with Gleason score ≤ 6 and PSA < 10, were reclassified as low-risk rather than left unclassified.
Gastrointestinal and genitourinary (GU) toxicities were assessed using common terminology criteria for adverse events (CTCAE) version 4.0. Acute GI and GU toxicities were defined as symptom occurrence within 3 months post-treatment, whilst late toxicities were described as symptom occurrence after 3 months post-treatment. Immediate or delayed post-operative complications following RS insertion, including, but not limited to, rectal tear, rectal perforation, rectal ulceration, rectal bleeding, infection, allergic reactions, and urinary retention were recorded in electronic medical records and/or on patient’s progress note at their first post-treatment follow-up with radiation oncologist. Assessing physicians were not blinded to the use of RS.
Planning and treatment
This study implemented the same volume study, treatment planning, and treatment techniques as previously reported by Chao et al. [27].
Any patient who underwent a pre-implant TURP had limited resection with only 3-5 grams of tissue removed. If an intravesical median lobe was present, the lobe was resected down to prostatic capsule. In some cases, patients also had a transurethral incision of the prostate (TUIP). Patients did not proceed to their implant until at least 3 months after their TURP, with urodynamic tests and cystoscopy performed to confirm resolution of outlet obstruction and urethral healing.
Rectal spacer insertion with either HS (SpaceOAR®, Boston Scientific, MA, USA) or HA (Barrigel®, Palette Life Sciences, Stockholm, Sweden) was performed at the end of an implant via transrectal ultrasound guidance by the treating radiation oncologist or urologist. 10 cc of Space-OAR© hydrogel spacer, or 9 cc of Barrigel© hyaluronic acid gel was introduced into the recto-prostatic space. RS insertion was performed at the end of the implant, as the use of RS could degrade the images of the prostate, therefore interfere with the implant of brachytherapy rods. It could also potentially elevate the prostate anteriorly and cause pubic arch obstruction.
Patients were admitted overnight with an indwelling catheter (IDC) and discharged after a successful trial of void in the following morning. All patients attended a follow-up with the urologist at 2 weeks post-implantation as well as a follow-up with the radiation oncologist at 4 weeks post-implantation for post-implant dosimetry using CT/MRI to verify for post-procedural complications. Placement of RS and the resultant prostate-rectum separation was characterized using MRI.
The patients were then followed-up every 3 to 4 months for the first year by the treating radiation oncologist, and every 6 months for the next 5 years. PSA testing was performed for at least first 4 years of follow-up, with biochemical failure defined as PSA nadir + 2 ng/l, following implant and exclusion of PSA bounce according to Phoenix definition [28].
Statistical analyses
Descriptive statistics were performed to evaluate characteristics of the patients demographics, disease, treatment features, and post-treatment toxicities, and test for differences between groups. Continuous variables were presented as mean ± standard deviation or median (interquartile range) for normal and non-normal variables, respectively, using Student’s t-test and Mann-Whitney test for differences between the two groups. Categorical variables were presented as counts and percentage frequencies, with chi-square or Fisher’s exact test applied to evaluate differences in distribution between the groups. Analysis of the association between RV100 with acute and late GI toxicities included categorizing RV100 based on thresholds of ≤ 0.5, > 0.5, ≤ 1.3, and > 1.3 as per previously published dose constraints [5, 7, 29, 30]. Evaluations of association between pre- and post-implant rectal D1cc and D2cc relations with GI toxicities included consideration of medians and/or thresholds, as determined by utilization of receiver operating curve (ROC) analysis. Potential confounding effects of RV100, D1cc, and D2cc values on the association between RS and late GI toxicity was explored using multi-variable logistic regression analysis. Multi-variable analysis could not be explored for acute GI toxicity due to no acute GI toxicity events in the RS cohort. Statistical analysis was conducted using Stata version 15.1 (StataCorp, College Station, Texas, USA), with statistical significance defined as p-value < 0.05.
Results
Patients’ characteristics
The mean age of the study population was 66.1 years (SD = 6.8) (Table 1). Of the 70 men enrolled in the study, 28 patients (40%) received RS insertion and 42 men (60%) did not receive RS. The median follow-up was 23.5 months (IQR = 20.75 months). It was 26.5 months (IQR = 17.5 months) for the patients who did not receive RS, and 13 months (IQR = 20.5 months) for the patients who received RS. There were 19 men (27%) with low-risk PCa, 49 (70%) with favorable intermediate-risk PCa, and 3 cases (4%) with unfavorable intermediate-risk PCa, with a statistically significant difference in cT-stages in patients with RS vs. patients without RS insertion (p = 0.025). Overall, 43 men (61%) underwent TURP prior to LDR-BT, whilst 9 men (13%) received downsizing ADT, with no statistically significant differences between the cohorts. The high volume of TURP was attributed to poor urinary flow and was performed at the discretion of the treating urologist with small volume resection (3-5 grams of tissues removed) for patients with poor flow.
Table 1
There was no statistically significant difference in the mean pre-radiotherapy (RT) PSA in patients treated with RS vs. non-RS group (5.0, SD = 2.6; 4.9, SD = 2.4; p = 0.91), or distribution in Gleason score (p = 0.53) or ISUP grading (p = 0.53).
There was no statistically significant difference in the number of patients treated with RS vs. patients not treated with RS (staging scan performed for almost all patients), who underwent MRI imaging (p = 0.64), CT staging (p = 1.00), WBBS (p = 1.00), or downsizing androgen deprivation therapy (ADT) (p = 1.00).
No PSA relapse was recorded in any men. The median follow-up PSA was 0.3 (IQR, 0.1-0.6) for men treated without RS, and 0.6 (IQR, 0.3-1.0) for men treated with RS (p = 0.019).
Dosimetry results
The mean prostate volume was 37.7 cc (SD = 9.1) (Table 2), with no statistically significant difference in the mean prostate volume recorded between men with RS vs. men without RS (p = 0.15; Table 2). The mean number of seeds inserted was 70.7 (SD = 7.9), with no differences between men with RS vs. men without RS (p = 0.42). No post-procedural insertion complications were recorded.
Table 2
No statistically significant difference was recorded for the mean urethral D20, D5, and D1 for men without RS insertion vs. men with RS insertion: 130.8% vs. 129.4% (p = 0.20), 137.1% vs. 135.5% (p = 0.22), and 145.0% vs. 141.5% (p = 0.061), respectively. Similarly, no statistically significant difference was recorded amongst the two groups for pre-RS insertion prostate D90, V100, V150, and V200, with 119.6% vs. 119.4% (p = 0.62), 98.6% vs. 98.6% (p = 0.42), 55.5% vs. 55.4% (p = 0.90), and 23.1% vs. 22.7% (p = 0.48), respectively, as well as for post-RS insertion prostate D90, V100, V150, and V200, with 98.5% vs. 99.6% (p = 0.66), 88.6% vs. 88.7% (p = 0.93), 50.3% vs. 48.9% (p = 0.58), and 23.6% vs. 22.0% (p = 0.61), respectively.
The median recto-prostatic separation, as measured from midline of the prostate, was 10 mm (IQR = 3.25 mm) in the patients who underwent RS. There was significantly reduced rectal dosimetry in men with RS vs. men without RS, i.e., RV100 = 0 cc (IQR = 0-0.0 cc) vs. RV100 = 0.4 cc (IQR = 0.1-1.1 cc), p < 0.001. Also, there was significantly reduced D1cc and D2cc in men with RS vs. men without RS. D1cc in men with RS was 52.4% vs. 84.2% in men without RS (p < 0.001). D2cc was 45.7% in men with RS vs. 70.0% in men without RS (p < 0.001).
Immediate and late GI and GU toxicities
There was a statistically significant difference in acute GI toxicity of 24% to 0% (p = 0.004) and in late GI toxicity of 33% to 4% (p = 0.003) in the non-RS vs. RS cohorts (Table 3). The only late GI toxicity in the RS cohort was observed in one patient with rectal bleeding. As shown in Table 3, the most common late GI toxicities observed in the non-RS cohort were grade 1 diarrhea, proctitis, and rectal bleeding. No acute or late grade 2 or higher GI toxicities were observed in either group.
Table 3
Table 4 demonstrates further analyses of the association between RV100, D1cc, and D2cc with acute and late GI toxicities. There was a statistically significant difference observed between patients with post-implant RV100 ≤ 0.5 and > 0.5 and late GI toxicity (15% vs. 39%, p = 0.049). As there were no pre-implant RV100 values beyond 1.3, no assessment of association with acute GI toxicity could be performed. Rates of acute GI toxicity were higher in post-implant RV100 values > 1.3 compared to ≤ 1.3 (29% vs. 13%) and for late GI toxicity (29% vs. 21%), but neither comparison was statistically significant (p = 0.26 and 0.64, respectively).
Table 4
Based on ROC analysis, acute GI toxicity was higher for patients with post-implant rectal D1cc values > 67.45 (25% vs. 3%, p = 0.014), with late GI toxicity also higher (36% vs. 6%, p = 0.003). Similarly, acute GI toxicity rates were higher for post-implant rectal D2cc values > 53.89 (23% vs. 3%, p = 0.035), with a cut-point > 54.81 maximizing the differential in late GI toxicity (35% vs. 6%, p = 0.003).
Univariate logistic regression analysis provided odds ratio of 0.07 (95% CI: 0.01-0.60%, p = 0.15) for log odds of late GI toxicity in the RS cohort, when compared to the non-RS cohort. After adjusting for post-implant RV100 > 0.5, statistical significance was maintained with a slightly higher odds ratio (OR = 0.09; 95% CI: 0.01-0.80%; p = 0.030). When adjusting for post-rectal D1cc and D2cc in separate models, statistical significance was not retained. Although, ORs were all in the order of < 0.2 (D1cc: OR = 0.19, 95% CI: 0.01-2.70%, p = 0.22; D2cc: OR = 0.16, 95% CI: 0.01-1.80%, p = 0.14), indicating that the association between RS and late GI toxicity was only marginally affected by confounding, and a strong association between RS and late GI toxicity remained.
Discussion
Safety analyses
This retrospective multi-institutional study demonstrated that RS insertion with HA or HS spacers were safe, with no post-operative complications identified. This remained consistent with safety analysis performed by Heikkilä et al. and Prada et al. for HS and HA spacer injections, respectively, with both studies showing no post-operative complications [17, 31]. Furthermore, a systematic review performed by Miller et al. showed a 97% success rate with HS insertion and a low rate of procedural complication (0-10% of patients), which were mild and transient in nature [32].
RS distance
The median distance of separation achieved in this cohort remained consistent to that reported in the literature. Similar recto-prostatic separations were described in intensity-modulated radiation therapy (IMRT) [19], LDR-BT, and HDR-BT using either HS or HA insertions [14, 21, 22, 33]. Significantly two systematic reviews have established similar prostate-rectum separation with HS insertion in EBRT, BT, and combination RT (11.2 mm) [32] as well as in LDR-BT and HDR-BT (10 mm) with that of the current study [25].
Dosimetry outcomes
The present study showed comparable prostate and urethral dosimetry measures for the cohort treated with RS and that not treated with RS. The post-implant constraints and dose goals were consistent with guidelines laid out by the American Association of Physicists in Medicine (AAPM) and the American Brachytherapy Society [29, 34]. Most significantly, rectal dosimetry measures were significantly reduced in the RS cohort when compared to the non-RS cohort. As outlined above, there was a significant reduction in RV100 post-RS insertion (0.4 cc in the non-RS cohort vs. 0.0 cc in the RS cohort; p < 0.001). The mean rectal D1cc and D2cc were both significantly reduced in patients with RS compared to the non-RS cohort (52.4% vs. 84.2% for D1cc, and 45.7% vs. 70.0% for D2cc; p < 0.001).
Reduced rectal dosimetry following RS insertion was widely reported in high-dose-rate brachytherapy (HDR-BT), including Chao et al. study, who demonstrated reduced rectal dose volumes from rectal V30 to rectal V80 following HS insertion [33,35]. Strom et al. observed that HS insertion in patients treated with HDR-BT with or without IMRT, demonstrated significantly reduced mean rectal D2 ml (47 ±9%) when compared to those without HS insertion (60 ±8%), with values similar to those reported in this study [36]. Significantly, Taggar et al. showed reduced D1cc and D2cc values for HS insertion in patients treated with LDR-BT with palladium-103 as monotherapy, with EBRT, or as salvage monotherapy, when compared to patients not treated with HS [13]. HA insertion was demonstrated to reduce rectal dosimetry in HDR-BT with EBRT and HDR-BT in gynecological cancers [31, 38]. In the setting of IMRT, a phase 3 multicenter randomized clinical trial has been performed with HS insertion, yielding a significant reduction in rectal V70 post-spacer insertion [39-41]. Another clinical trial by van Gysen et al. was demonstrated a significant reduction in rectal doses (V30 to V80) post-HS insertion in 10 patients treated with volumetric modulated arc therapy (VMAT) [42]. These findings suggest that HS insertion produces a consistent reduction in rectal dosimetry across different radiotherapy settings.
Placement of HS in patients treated with 125I LDR-BT was demonstrated by Morita et al., showing reduced RV150 and RV100 compared with those not treated with HS [43]. Furthermore, a systematic review, which included 12 studies of HS insertion in the setting of LDR-BT and HDR-BT with or without EBRT, VMAT, or IMRT demonstrated that rectal doses were reduced across all these different settings [25]. Further studies by Kahn et al., Butler et al., Patel et al., Taggar et al., Zhang et al., and Liu et al. all showed improvements in rectal dosimetry post-HS insertion for patients treated with LDR-BT with or without EBRT [13, 44-49]. As such, the reduced rectal dosimetry post-RS insertion in the present study were comparable to, and reaffirming findings from, current literature on LDR-BT.
Toxicity outcomes
There was no statistically significant difference in acute or late grade 1 to 3 GU toxicities between the RS group and the non-RS group (Table 3). No acute or late grade 4 GU toxicities were recorded in this study. Similar incidence of GU toxicities were reported by Uhl et al., where HS cohort experienced 41.7% acute grade 1, 35.4% grade 2, and 2.1% grade 3 GU toxicities, and 17% late grade 1 and 2.1% late grade 2 GU toxicities [50]. Chao et al. reported no statistically significant difference in acute or late GU toxicities between group treated with HS and group not treated with HS in HDR-BT with or without EBRT [33]. This study showed that RS insertion did not increase the incidence of acute or late ≥ grade 1 GU toxicities, with reported incidences comparable to the current literature.
The present study demonstrated a statistically significant reduction in acute and late GI toxicities post-RS insertion, which were supported by findings of the literature. Wilder et al. showed that HA insertion yielded an incidence of 0% acute grade 1 to 3 acute diarrhea in 10 treated patients following IMRT and HDR-BT, when compared to an incidence of 29.7% in patients who did not receive HA [51]. Taggar et al. reported an incidence of 9.5% grade 1 rectal discomfort or rectal bleeding post-HS insertion for LDR-BT with or without EBRT [13]. A systematic review performed by Vaggers et al. on HS use in prostate brachytherapy described an acute grade 1 or 2 GI toxicity rate of 33.7% and a low-rate of grade 3 or 4 GI complications (0.22%) [52]. In the Australian setting, Chao et al. reported a statistically significant reduction in acute ≥ grade 1 GI toxicity in HS patients treated with HDR-BT and EBRT compared to non-HS group [33]. Low rates of late grade 1 GI toxicity in both groups were reported (0% in HS group and 7.7% in non-HS group, p = 0.11). A systematic review and meta-analysis by Miller et al., who included patients treated with BT, EBRT, or combination therapy, showed that reduced rectal dosimetry in HS-treated group translated to a significant reduction in late grade 2 or above GI toxicities as well as significant improvement in bowel-related quality of life at late follow-up [32]. Another systematic review by Ardekani et al. focused on patients treated with LDR-BT or HDR-BT also demonstrated a reduction in acute and late GI toxicities post-HS insertion [25]. Furthermore, several other research have also reported significant reduction in acute and late rectal toxicities post-RS insertion in LDR-BT as monotherapy, or as combination therapy [13, 45, 46, 53] in HDR-BT [25, 32, 35, 37, 54, 55], and particularly in the settings of IMRT in large-scale multi-institutional randomized clinical trial [39-41].
Statistical analyses presented in Tables 4 and 5 further support a strong correlation between the reduction of rectal dosimetry (RV100, rectal D1cc and D2cc) and the reduction in acute or late GI toxicities. Significantly, reducing RV100 to ≤ 0.5 yielded a lowered rate of late GI toxicity, when compared to the cohort of patients who received RV100 > 0.5. This was consistent with findings from Veccia et al. who reported improvements in acute and late rectal functions when post-implant RV100 was restricted to ≤ 0.5 [7]. Similarly, Shiraishi et al. also reported a reduction in rates of grade 2 rectal bleeding in patients treated with 125I BT combined with EBRT, when RV100 was ≤ 0.5 ml [30]. Furthermore, reduction of rectal D1cc and D2cc (below ROC values) also demonstrated a significant reduction in acute and late GI toxicities. Adjusting for these confounding effects through multi-variable analysis maintained the reduced acute and late GI toxicity rates for patients with RS insertion, further supporting evidence from the current literature [4-6, 22, 27].
Table 5
Therefore, the reported reduction in acute and late GI toxicities following RS insertion in this study reaffirms the results of current literature and strengthens understanding in the setting of 125I LDR-BT monotherapy.
Study strength and limitations
The patients’ demographics and underlying pathological features of diseases for the two investigated cohorts in this study were comparable in nature, except for cT stage, where a higher proportion of T2a patients were present in the non-RS cohort. However, there was no indication that cT stage was associated with a higher likelihood of GI toxicity, which minimized the probability of difference in cT stage as a strong confounding variable impacting on identified statistically significant difference in acute and late GI toxicities.
One significant advantage of this study was its’ demonstration of association between reduced rectal dosimetry and acute and late GI toxicities. Furthermore, the statistical analyses allowed for an assessment of association between the effect of RS on GI toxicity outcomes, adjusting for rectal dosimetry values. This provided a new insight into the efficacy of RS in LDR-BT, which currently lacks sufficient evidence. Although, one limitation of this study was its’ relatively small sample size, reducing the power of the study, and inability to detect statistically significant associations between RS and GI toxicities after adjusting for post-rectal D1cc and D2cc values, despite the positive effect of RS on reducing late GI toxicity, as shown by the magnitude of odds ratios from multi-variable analysis.
This multi-institutional approach used in this study, involving multiple community-based private radiation oncology centers, provided a larger sample size with a diverse, yet comparable patients’ population, which allowed the data to be easily interpreted and applied by a wider variety of medical practitioners in their clinical practice. It also minimized issues of bias surrounding clinical practice, accessed barriers, and selection bias in single-institutional studies. Significantly, clinical practice, involving patient workup, imaging choice, and treatment modality, remained consistent across different campuses involved in this community-based study.
Despite efforts to minimize selection bias, the risk of bias still exists in this study due to the nature of its’ design, which could be further minimized with a randomized clinical trial. The discretion of spacer implantation and choice of RS by the treating urologist was another major limitation of this study, which could be minimized with a blinded study with a 1 : 1 case-control randomization. The RS cohort had a shorter median follow-up duration when compared to the control cohort, which could contribute to the observed reduction in late GI toxicity outcomes. As such, a study with a longer duration of follow-up could further establish the effect of RS on late GI toxicity.
Conclusions
This Australian community-based retrospective study demonstrated that RS insertion with either HS or HA gel for treatment of low-risk and intermediate-risk PCa patients using 125I LDR-BT was safe and effective in reducing rectal dosimetry as well as decreasing early GI toxicity. Our early data suggests that reduction in rectal dosimetry may translate to lower long-term GI toxicity. This approach also maintained comparable prostate dosimetry and similar rates of acute and late GU toxicities, when compared to patients not treated with a RS insertion. A randomized clinical trial could help further appreciate and quantify the risks and benefits of RS insertion in this clinical setting.