eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

1/2021
vol. 13
 
Share:
Share:
Original paper

Venezia applicator with oblique needles improves clinical target volume coverage in distal parametrial tumor residue compared to parallel needles only

Manon Kissel
1
,
Nathalie Fournier-Bidoz
2
,
Olivier Henry
2
,
Sophie Bockel
1
,
Tamizhanban Kumar
1
,
Sophie Espenel
1
,
Cyrus Chargari
1

  1. Radiation Therapy Department, Gustave Roussy, Villejuif, France
  2. Medical Physics Department, Gustave Roussy, Villejuif, France
J Contemp Brachytherapy 2021; 13, 1: 24–31
Online publish date: 2021/02/18
Article file
Get citation
 
 

Purpose

External beam radiation therapy (EBRT) with concurrent platinum-based chemotherapy, followed by brachytherapy is the standard treatment of locally advanced cervical cancer. In the last decades, major advances have been made in the field of brachytherapy, with image-guided brachytherapy development (2D, 3D, then magnetic resonance imaging (MRI)-based) or standardized delineation and dose prescription [1,2]. The interstitial adjunct to intracavitary brachytherapy in large tumors has been shown to improve local control of 2-3% per each Gray delivered [3,4,5], and to be the best modality to treat parametrial extent. EBRT parametrial boosts have been shown to increase severe bowel morbidity and deliver inferior doses than brachytherapy, therefore they should be definitely abandoned in routine practice [6,7,8].
Patients with a distal parametrial residue after radiochemotherapy have a dismal prognosis, partly because dose escalation is quite difficult in such cases, even with brachytherapy. This kind of tumors is classified as group 5 in an analysis of EMBRACE (image-guided intensity-modulated external beam radiochemotherapy and MRI-based adaptative brachytherapy in locally advanced cervical cancer) prospective cohort, corresponding to poor response. This group was characterized by a significantly lower dose to high-risk clinical target volume (HR-CTV) (mean D90, 88.4 Gy in this group versus > 90 Gy in groups 1 to 3, corresponding to small tumors with good or moderate response, p < 0.001). Recent data from the EMBRACE study show that this situation is not infrequent: 16% of patients have a distal parametrial residue after radiochemotherapy [9]. Furthermore, retrospective data suggest that tumors with poor volumetric response after EBRT (< 90%) require higher doses to be eradicated, as compared to tumors with good shrinkage [10]. Distal parametrial extension is a true challenge for brachytherapists. Historically, free-hand needles’ insertion or perineal templates were used to implant needles in the outer third of parametria. Perineal templates, such as Syed-Neblett or MUPIT (multiple site perineal applicator), seem superior to intracavitary brachytherapy alone to treat the most lateral part of parametria [11]. However, parallelism is usually maintained only in the proximal part of the needles, there is a risk of divergence or convergence when these kinds of templates are used to treat the parametrium, especially its upper part, because of the distance between the template and the region of interest [12]. Using free-hand technique, one has no possibility to precisely control clinically the path of needle. Fluoroscopy may be helpful in the left-right direction, but not in the anterior-posterior direction [12]. Furthermore, distal parametrial regions are characterized by proximity of fragile structures, such as uterine arteries, ureters, rectum, and bladder, which are not visible on fluoroscopy. Peroperative MRI or ultrasound guidance in this context seem to be precise, but are not yet a routine practice in all centers [13,14,15]. The risks of vascular or bowel injuries, though relatively low, need to be also considered [16].
While reducing the distance between the point of insertion and the target, the use of a vaginal applicator to implant parametrial regions seems to be particularly relevant. Some commercial hybrid applicators have been developed in this perspective, combining intracavitary and interstitial components, where the interstitial component originated from vaginal fornixes, the two major ones used in clinical practice being the ViennaTM and the UtrechtTM applicators. The ViennaTM applicator is a ring applicator allowing for insertion of at most 9 parallel needles through the ring acting as a template [4]. The UtrechtTM applicator is a Fletcher design-based tandem, where each ovoid is a template for three to five needles in one or two parallel planes [5]. Both applicators allow for parallel needles only and may treat inner third to half of the parametria. The recently developed VeneziaTM advanced gynecological applicator (Elekta©, Stockholm, Sweden) combines two lunar-shaped ovoids, forming a ring through which, parallel and oblique interstitial needles can be inserted (22 mm ring diameter: up to 6 parallel and 6 oblique needles, 26 mm and 30 mm ring diameters: up to 8 parallel and 8 oblique needles) [17]. The divergent needles span out and may treat a larger part of the parametria. Here, we report five cases of VeneziaTM use as a way to treat distal parametrial extensions with brachytherapy.

Material and methods

Plans of the first five patients treated with the VeneziaTM applicator using oblique needles at our institution were reviewed. Patients were considered for inclusion if they had a distal parametrial residue after radiochemotherapy for a locally advanced cervical cancer. At 40-45 Gy, all patients had a clinical examination, and 4 patients additionally underwent MRI to guide the choice of applicator. The VeneziaTM applicator with a 26 mm diameter ring was used, combined with blunt-end plastic tubes (ProGuide round needles, 6F × 294 mm, Nucletron) inserted through straight holes and oblique holes angled at 20°. The number, position, and depth of needles were determined by a radiation oncologist considering the size and shape of residual tumor after radiochemotherapy. For each patient, MRI was performed with the applicator in situ for delineation and dosimetry (Figure 1). HR-CTV, intermediate-risk CTV (IR-CTV), rectum, bladder, sigmoid colon, and small intestines were delineated on MRI according to Groupe Européen de Curiethérapie – the European Society for Radiotherapy and Oncology (GEC-ESTRO) recommendations, using Oncentra Brachy treatment planning software (version 4.6.0, Elekta) [2]. Pulsed-dose-rate (PDR) brachytherapy was exclusively used. Total prescription dose including EBRT was 85 Gy (EQD210) to HR-CTV. Brachytherapy prescription dose to IR-CTV was 15 Gy. The number of pulses depended on the dose delivered per hour, constrained by the limitation of 0.6 Gy/h on organs at risk (OARs). The equivalent dose in 2 Gy fractions (EQD2) sum of brachytherapy and EBRT was calculated, assuming α/β value of 10 Gy for target volume and α/β value of 3 Gy for OARs, according to linear quadratic model and considering repair halftime of 1.5 h for PDR [18].
For each patient, we performed a comparative dosimetry using the parallel needles only (Vienna plan) and both the parallel and oblique needles (Venezia plan). In order to do so, the Venezia plan was duplicated and all activation in the oblique needles was shut down. The contours and number of pulses were unaltered between both plans for each patient. Then, manual dwell time optimization was made jointly by experienced pair of radiation oncologist (MK) and physicist (NF). Dwell time positions could be increased on the tandem, on the parallel needles, and on the free-hand needles (in some cases free-hand needles were inserted besides the applicator) in the way deemed to be optimal. Optimization was made in the fairest conditions possible, aiming to deliver the maximum possible dose to the target, while respecting a classical repartition for PDR in terms of needle contribution relative to total activation. The portion of the needles remaining inside the vagina was not activated, since vaginal caps cannot be used with oblique needles in the Venezia applicator. The most proximal dwell position was always above the superior plane of the ring to avoid any overdosage at the vaginal mucosa level. For both plans, the optimization process was halted when HR-CTV EQD210 D90 reached 90 Gy, when a hard constraint on OARs was reached according to the EMBRACE II protocol (D2cc bladder ≥ 90 Gy, D2cc rectum ≥ 75 Gy, D2cc sigmoid ≥ 75 Gy, D2cc bowel ≥ 75 Gy) [19], or when dose-rate on an OAR exceeded 0.6 Gy/h [20]. Conformation number (CN) was calculated for each plan using the following formula: where VRI is the volume encompassed by the prescription isodose, HR-CTV is the HR volume in cc, and HR-CTV RI is the target volume covered by the prescription isodose [21]. We considered the EQD210 85 Gy isodose as the prescription dose. The CN evaluated how well the prescription isodose line matches the HR-CTV volume, with “1” representing the best possible match and “0” indicating no overlap. In order to obtain a graphic representation of dosimetric comparison between plans, Raystation® treatment planning software (RaySearch Laboratories, Stockholm, Sweden) was used. Dose comparison between the two sets of plans for each patient was performed by Student’s t-test for matched data. A p value of 0.05 was considered significant. Statistical analyses were performed using R software, version 4.0.2. The present study was conducted in accordance with the ethical principles of the Declaration of Helsinki, and did not require further ethical committee approval.

Results

Five patients were retrospectively included in the present study. All patients had a locally advanced cervical cancer, staged as T3b or T4a disease at diagnosis, and had at least a unilateral distal parametrial residue at brachytherapy. All patients had received radiochemotherapy with weekly cisplatin 40 mg/m². EBRT doses were 45 Gy in 25 fractions for all but one patient (50.4 Gy in 28 fractions delivered in Kuwait), who was referred to our institution for a brachytherapy boost. An EBRT boost on involved nodes was delivered when appropriate, up to EQD210 dose of 60 Gy, taking into consideration the planned brachytherapy dose [22]. Patients’ and treatments’ characteristics are reported in Table 1.
A median of 6 parallel needles and 7 oblique needles were inserted. Additional free-hand needles were implanted in three patients to cover para-vaginal or peri-urethral invasion. No complication occurred during or following the procedures. Median HR-CTV volume was 64 cc, and median distance between tandem and outer lateral contour of HR-CTV was 40 mm. Median follow-up was 3 months. One patient developed an asymptomatic rectal ulceration, which was found during clinical examination 3 months after brachytherapy. No grade 2 or higher toxicity occurred to last follow-up date. At last follow-up, three patients achieved complete response and one patient achieved good partial response (one patient had not been re-evaluated yet).
For the five patients, HR-CTV D90 EQD210 was superior in the plan using the oblique needles, with a median difference of 6.5 Gy (range, 1.7-8.5 Gy) (Table 2). Median D90 HR-CTV was significantly higher in the VeneziaTM plans, with 85.9 Gy (range, 83.2-90.3 Gy) vs. 81.5 Gy in the ring plans (range, 77.4-84 Gy), p = 0.006 (Table 2 and Figure 2). Median IR-CTV D90 was also significantly superior in the VeneziaTM plans, with 68.7 Gy (range, 66.3-72.3 Gy) vs. 67 Gy (range, 64.3-69.1 Gy), p = 0.006. For one patient (Pt No. 2), the gain on HR-CTV with oblique needles was lower because there was a large part of residual tumor lying in the upper and posterior part of the uterine body, invading the myometrium almost up to serosa, and the maximum dose to bowel was quickly reached. There were no significant differences in the dose to OARs (Table 2). In the ring plans, median EQD23 D2cc to rectum, bladder, sigmoid, and bowel were 68.1 Gy, 83.7 Gy, 56.9 Gy, and 72.7 Gy, respectively. In the VeneziaTM plans, median D2cc to rectum, bladder, sigmoid, and bowel were 72.5 Gy, 80.8 Gy, 57.2 Gy, and 73.6 Gy, respectively (p = 0.20, 0.89, 0.62, and 0.37, respectively). Median total reference air-kerma (TRAK) was 2.55 cGy/m2 in the ring plans, and 2.64 cGy/m2 in the VeneziaTM plans (p = 0.17).
The dose to CTV was definitely numerically superior with VeneziaTM but dose distribution was quite different between the plans with oblique needles and the ones without. For most patients, in the plans using only the parallel needles, ring activation had to be markedly increased to compensate for the absence of oblique needles, and still attempting to cover the inferior part of parametria (Figure 3). As a consequence, the vaginal/TRAK ratio was statistically higher in the plans with parallel needles only (34% vs. 28% in the Venezia plans, p = 0.01), and in two cases exceeding the recommended 40%, as a secondary objective in the EMBRACE II protocol (Table 2). Moreover, all plans using parallel needles only had cold spots in the distal parametrial area compared with the plan with oblique needles. The oblique needles “extended” the dose to the side, thus allowing to treat correctly very asymmetrical tumors, provided a correct implantation (Figure 3). Median conformation number was 0.52 in the ring-like plans and 0.58 in the VeneziaTM plans. The difference was at the limit of significance (p = 0.09).

Discussion

As recently reported in literature, we showed that VeneziaTM applicator is a safe way to increase CTV coverage while maintaining dose to OARs [23]. Our study demonstrated a clinically meaningful gain of more than 6 Gy in terms of HR-CTV coverage with oblique needles in patients with distal parametrial residue after radiochemotherapy. Moreover, a crucial advantage on the topographic repartition of the dose in the distal parametrial areas was observed.
The association of intracavitary and interstitial (IC/IS) approach has already been shown to improve local control by 10% in “large” (> 30 cm3) or poorly responding tumors with acceptable toxicity [24]. Here, we report on 5 patients with very large tumors; in our cases (Tables 1 and 2), HR-CTVs were at least twice or even three times larger than 30 cm3. In the literature, the addition of interstitial component escalated target coverage without increasing doses to OARs, and enhanced a therapeutic window by an average of 4 to 8 Gy EQD2 [4,5,25]. This has been confirmed recently in the large prospective trial EMBRACE I, where for a HR-CTV volume of 60 cm3, which is comparable to the patients included in our study, mean HR-CTV D90% was 5.4 Gy (95% CI: 2.7-8.1) higher for ovoids-IC/IS compared with ovoids-IC centers, and 8.9 Gy (95% CI: 7.0-10.7) higher for ring-IC/IS compared with ring-IC centers [26].
The Utrecht applicator is widely appreciated for its ability to treat parametrial involvements, especially when large ovoids can be used. Indeed, ovoids ≥ 20 mm allow for two planes of parametrial needles, but both remaining generally in the proximal parametrium. Ring applicators were shown to have better target dose and dose conformity than ovoids applicators [26]. If 95% of tumors are estimated to be correctly covered by ViennaTM-type applicator [27], the remaining 5% of patients will require an oblique implant to reach acceptable target coverage. The first published report on a commercially available applicator with transvaginal oblique implants was the modified ViennaTM ring applicator described by Berger et al. in 2010 [28]. A specially designed removable semi-template bearing clockwise oblique holes could be fixed to the ring. This applicator was tested in 6 patients with distal parametrial disease at the time of brachytherapy. Needle loading was maximum 20% of intracavitary contribution. With HR-CTVs of mean 50 cm3, mean EQD210 D90 was 86 Gy. Mean EQD23 D2cc for OARs were 79 Gy, 61 Gy, and 67 Gy for bladder, rectum, and sigmoid, respectively. Aarhus also published their experience with oblique transvaginal implants in 2012, where a 3D-printed needle cap was attached to a commercially available tandem-ring applicator [29,30]. A good coverage was achieved with this technique in patients with large tumors. For example, in 27 patients with a mean HR-CTV volume of 53 cc, a mean D90 HR-CTV of 87 ±6 Gy was delivered [29]. In another publication, in 23 patients with a mean HR-CTV volume of 48 cc, a mean D90 HR-CTV of 89 ±3.4 Gy was reported [6]. The largest experience ever reported was with the Vienna II applicator, which is a ViennaTM applicator with an add-on cap allowing for additional oblique needles into the distal parametrium [31]. Mean distance between tandem and outer contour of HR-CTV was 38 mm, and mean HR-CTV (±SD) volume was 69 ±32 cm3, which is comparable to the patients in our cohort. Among 69 patients with distal parametrium residue after radiochemotherapy, a mean (±SD) EQD210 D90 HR-CTV was 86 ±7 Gy and a mean EQD23 D2cc for bladder, rectum and sigmoid were 86 ±12, 68 ±7 and 68 ±9 Gy, respectively. This is consistent with what we obtained in the plans using oblique needles. However, intra-operative utero-vaginal complications or arterial bleeding during removal occurred in 14 patients in this study (20%), and long-term high-grade toxicity were high compared to existing literature, since 20% of the patients had at least one grade 3/4 toxicity [32,33].
Another recent study reported on differences in dosimetry of high-dose-rate (HDR) brachytherapy treatments between plans using advanced multichannel applicators and their simplified base versions [34]. For VeneziaTM, the simplified plan had all interstitial needles deleted, whereas in our study, only the oblique ones were shut down. The simplified applicator plans each utilized the same inverse planning optimization parameters from their original advanced applicator plan to generate a new dose distribution. After optimization, each simplified plan was renormalized to match D90 HR-CTV of original advanced plan within 0.4%. By doing this, they compared critical structure doses for similarly effective plans, while our approach was to remain clinically acceptable on OARs, and to see how the advanced applicator could increase CTV coverage. Comparing simplified to advanced Venezia plans in their study, the doses to all organs were significantly lower with the exception of rectum, with an average percent differences in EQD23 to 2 cm3 of 101.7 ±85.9%, 147.8 ±76.7%, 95.3 ±61.6%, and 44.0 ±12.4% for rectum, bladder, sigmoid, and bowel, respectively. Conformation number was better by 0.251 (p < 0.05), while in our study, the gain was naturally lower (0.06, p = 0.07), since the only difference between both plans in our study was the presence of oblique needles. Vaginal de-escalation was not addressed in this study but vaginal stenosis is a frequent late side effect that can impact quality of life after brachytherapy. In our study, in order to treat very large tumors without oblique needles, the ring activation was mathematically increased to cover the inferior parts of parametrial involvement. However, as promoted in the EMBRACE II trial, vaginal dose de-escalation is a challenge for modern brachytherapy without compromising local control, since toxicity is highly correlated with vaginal brachytherapy dose [35,36].
The limitation of our study is its small size and retrospective nature. However, it is of importance to show how the use of oblique needles as designed in the Venezia applicator could lead to a good coverage of very large tumors while avoiding a detrimental overdosage of the vagina wall. The dose difference patterns between the Venezia and the parallel-only needles plans, plotted in Figure 3, demonstrate where the oblique needles were needed within the target volume (cold blue colored areas), and how much the dose increase in the vagina wall may have occurred without them (warm red colored areas).
Similarly, PDR is not perfectly reproducible with HDR, since dose-rate in PDR is limited to 0.6 Gy/h on OARs but on the other hand, the differential between OARs and EQD2 to HR-CTV is greater in HDR. The drawback of the Venezia applicator is its high cost, which can limit its wider use in low- or middle-income countries with high prevalence of cases with cervical cancer, especially large tumors. The other technical limitation is that the brachytherapists have to choose between the vaginal caps and oblique needles (the former clogging the oblique holes once in place) when performing the Venezia implant. As a consequence, a tumor presenting with both distal parametrial and lower vaginal tumor residue may be a challenge to cover properly without additional free-hand needles. Even though different semi-lunar ovoids diameter, uterine tandem angle, and length are available, commercial applicators do not always fit all anatomies, especially narrow or massively invaded vaginas. 3D printing is a very interesting line of research that could allow for a custom-made and inexpensive way of further tailoring brachytherapy dose distribution for patients with intricate anatomies or wide/asymmetrical/complex tumor residues after radiochemotherapy [37]. The personalized vaginal mould applicator may also be used to complete the treatment at the level of vagina or to provide personalized interstitial application; however, the number of needles that can be used is quite limited [38].
To conclude, we showed how the VeneziaTM applicator may be a safe and effective way to treat distal parametrial extensions during brachytherapy. In our study, the mean gain by adding oblique needles to an IC/parallel IS implant on HR-CTV was 6.5 Gy without raising the dose to OARs, which is in line with what can be expected when adding an interstitial component to an intracavitary implant. The EMBRACE II study is currently recording brachytherapy techniques using oblique needles, and may definitely validate their relevance in terms of local control and long-term toxicity.

Disclosure

Cyrus Chargari reports personal fees and non-financial support from Takeda, MSD, GSK, and Elekta outside the submitted work as well as support for clinical research from TherAgulX and Roche. The remaining authors report no conflict of interest.

References

1. Pötter R, Haie-Meder C, Limbergen EV et al. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy – 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology. Radiother Oncol 2006; 78: 67-77.
2. Haie-Meder C, Pötter R, Van Limbergen E et al. Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. Radiother Oncol 2005; 74: 235-245.
3. Fokdal L, Sturdza A, Mazeron R et al. Image guided adaptive brachytherapy with combined intracavitary and interstitial technique improves the therapeutic ratio in locally advanced cervical cancer: Analysis from the retroEMBRACE study. Radiother Oncol 2016; 120: 434-440.
4. Kirisits C, Lang S, Dimopoulos J et al. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results. Int J Radiat Oncol Biol Phys 2006; 65: 624-630.
5. Nomden CN, de Leeuw AAC, Moerland MA et al. Clinical use of the Utrecht applicator for combined intracavitary/interstitial brachytherapy treatment in locally advanced cervical cancer. Int J Radiat Oncol Biol Phys 2012; 82: 1424-1430.
6. Mohamed S, Kallehauge J, Fokdal L et al. Parametrial boosting in locally advanced cervical cancer: combined intracavitary/interstitial brachytherapy vs. intracavitary brachytherapy plus external beam radiotherapy. Brachytherapy 2015; 14: 23-28.
7. Huang EY, Wang CJ, Hsu HC et al. Dosimetric factors predicting severe radiation-induced bowel complications in patients with cervical cancer: combined effect of external parametrial dose and cumulative rectal dose. Gynecol Oncol 2004; 95: 101-108.
8. Fenkell L, Assenholt M, Nielsen SK et al. Parametrial boost using midline shielding results in an unpredictable dose to tumor and organs at risk in combined external beam radiotherapy and brachytherapy for locally advanced cervical cancer. Int J Radiat Oncol Biol Phys 2011; 79: 1572-1579.
9. Jastaniyah N, Yoshida K, Tanderup K et al. A volumetric analysis of GTVD and CTVHR as defined by the GEC ESTRO recommendations in FIGO stage IIB and IIIB cervical cancer patients treated with IGABT in a prospective multicentric trial (EMBRACE). Radiother Oncol 2016; 120: 404-411.
10. Schernberg A, Bockel S, Annede P et al. Tumor shrinkage during chemoradiation in locally advanced cervical cancer patients: prognostic significance, and impact for image-guided adaptive brachytherapy. Int J Radiat Oncol Biol Phys 2018; 102: 362-372.
11. Hsu ICJ, Speight J, Hai J et al. A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model. Int J Radiat Oncol Biol Phys 2002; 52: 538-543.
12. Nag S, Martínez-Monge R, Ellis R et al. The use of fluoroscopy to guide needle placement in interstitial gynecological brachytherapy. Int J Radiat Oncol Biol Phys 1998; 40: 415-420.
13. Popowski Y, Hiltbrand E, Joliat D et al. Open magnetic resonance imaging using titanium-zirconium needles: improved accuracy for interstitial brachytherapy implants? Int J Radiat Oncol Biol Phys 2000; 47: 759-765.
14. Rodgers JR, Bax J, Surry K et al. Intraoperative 360-deg three-dimensional transvaginal ultrasound during needle insertions for high-dose-rate transperineal interstitial gynecologic brachytherapy of vaginal tumors. J Med Imaging (Bellingham) 2019; 6: 025001.
15. Rodgers JR, Surry K, Leung E et al. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy. Med Phys 2017; 44: 1899-1911.
16. Mendez LC, Weiss Y, D’Souza D et al. Three-dimensional-guided perineal-based interstitial brachytherapy in cervical cancer: A systematic review of technique, local control and toxicities. Radiother Oncol 2017; 123: 312-318.
17. Walter F, Maihöfer C, Schüttrumpf L et al. Combined intracavitary and interstitial brachytherapy of cervical cancer using the novel hybrid applicator Venezia: Clinical feasibility and initial results. Brachytherapy 2018; 17: 775-781.
18. Leborgne F, Fowler JF, Leborgne JH et al. Biologically effective doses in medium dose rate brachytherapy of cancer of the cervix. Radiat Oncol Investig 1997; 5: 289-299.
19. Pötter R, Tanderup K, Kirisits C et al. The EMBRACE II study: The outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studies. Clin Transl Radiat Oncol 2018; 9: 48-60.
20. Castelnau-Marchand P, Chargari C, Maroun P et al. Clinical outcomes of definitive chemoradiation followed by intracavitary pulsed-dose rate image-guided adaptive brachytherapy in locally advanced cervical cancer. Gynecol Oncol 2015; 139: 288-294.
21. van’t Riet A, Mak AC, Moerland MA et al. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. Int J Radiat Oncol Biol Phys 1997; 37: 731-736.
22. Bacorro W, Dumas I, Levy A et al. Contribution of image-guided adaptive brachytherapy to pelvic nodes treatment in locally advanced cervical cancer. Brachytherapy 2017; 16: 366-372.
23. Fredman E, Traughber B, Podder T et al. 3T multiparametric MRI-guided high-dose-rate combined intracavitary and interstitial adaptive brachytherapy for the treatment of cervical cancer with a novel split-ring applicator. Brachytherapy 2018; 17: 334-344.  
24. Fokdal L, Sturdza A, Mazeron R et al. Image guided adaptive brachytherapy with combined intracavitary and interstitial technique improves the therapeutic ratio in locally advanced cervical cancer: Analysis from the retroEMBRACE study. Radiother Oncol 2016; 120: 434-440.
25. Fokdal L, Tanderup K, Hokland SB et al. Clinical feasibility of combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer employing MRI with a tandem/ring applicator in situ and virtual preplanning of the interstitial component. Radiother Oncol 2013; 107: 63-68.
26. Serban M, Kirisits C, Leeuw A de et al. Ring versus ovoids and intracavitary versus intracavitary-interstitial applicators in cervical cancer brachytherapy: results from the EMBRACE I study. Int J Radiat Oncol Biol Phys 2020; 106: 1052-1062.
27. Petric P, Hudej R, Al-Hammadi N et al. Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy. Radiol Oncol 2016; 50: 433-441.
28. Berger D, Pötter R, Dimopoulos JCA et al. New Vienna applicator design for distal parametrial disease in cervical cancer. Brachytherapy 2010; 9: S51-S52.
29. Tanderup K, Nielsen SK, Nyvang GB et al. From point A to the sculpted pear: MR image guidance significantly improves tumour dose and sparing of organs at risk in brachytherapy of cervical cancer. Radiother Oncol 2010; 94: 173-180.
30. Lindegaard JC, Tanderup K. Counterpoint: Time to retire the parametrial boost. Brachytherapy 2012; 11: 80-83.
31. Mahantshetty U, Sturdza A, Naga CP et al. Vienna-II ring applicator for distal parametrial/pelvic wall disease in cervical cancer brachytherapy: An experience from two institutions: Clinical feasibility and outcome. Radiother Oncol 2019; 141: 123-129.
32. Sturdza A, Pötter R, Fokdal LU et al. Image guided brachytherapy in locally advanced cervical cancer: Improved pelvic control and survival in RetroEMBRACE, a multicenter cohort study. Radiother Oncol 2016; 120: 428-433.
33. Pötter R, Georg P, Dimopoulos JCA et al. Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer. Radiother Oncol 2011; 100: 116-123.
34. Schnell E, Thompson S, Ahmad S et al. Dosimetric considerations when utilizing Venezia, Capri, Rotte double tandem, and tandem and ring with interstitial needles for the treatment of gynecological cancers with high dose rate brachytherapy. Med Dosim 2020; 45: 21-27.
35. Mohamed S, Lindegaard JC, Leeuw AAC de et al. Vaginal dose de-escalation in image guided adaptive brachytherapy for locally advanced cervical cancer. Radiother Oncol 2016; 120: 480-485.
36. Kirchheiner K, Nout RA, Lindegaard JC et al. Dose–effect relationship and risk factors for vaginal stenosis after definitive radio(chemo)therapy with image-guided brachytherapy for locally advanced cervical cancer in the EMBRACE study. Radiother Oncol 2016; 118: 160-166.
37. Lindegaard JC, Madsen ML, Traberg A et al. Individualised 3D printed vaginal template for MRI guided brachytherapy in locally advanced cervical cancer. Radiother Oncol 2016; 118: 173-175.
38. Magné N, Chargari C, SanFilippo N et al. Technical aspects and perspectives of the vaginal mold applicator for brachytherapy of gynecologic malignancies. Brachytherapy 2010; 9: 274-277.
Copyright: © 2021 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.